JUKI贴片机错误代码集合.pdf - 第98页

There is a Component or Pick dat a that is from a feeder which i s not set 'to use ' i n the Setup. [Treatment] Please go to the Production Program Edi tor and see the Componen t and Pick data. E500230 “ An err…

100%1 / 464
[Treatment]
In the Production dialog, please select a production mode that is NOT currently selected.
E500214 Reference error from the Pick data to the Component data
从吸取数据到组件数据的参考错误
[Cause]
The error appears when the Pick data and Component data are broken.
[Treatment]
This is a program error. Please make a note of the cause of the error and the error code, then contact
our technical service Dept. for information.
E500215 In the accumulative mode, the number of PWBs to be produced is the same as that of produced
PWBs. Production can not be executed
生产累加模式上,计划生产枚数和实际生产枚数相同,|不能进行生产。
[Cause]
[accumulate the number of produced PWBs] is checked in the Operation option, and the number of
produced PWBs in the Production dialog already exceeded the number of PWBs to be produced.
Therefore, the production can not be started.
[Treatment]
Please re-set a number of PWBs to be produced that is bigger than the number of produced PWBs, or
disable [accumulate the number of produced PWBs] in the Operation option.
E500216 The pick point does not exist on the station side for which the head is specified.”
Head 被指定的站台侧,不存在吸取数据
E500217 The number of sheets of the production schedule becomes '0' set (infinite the number of
sheets) in the subtraction mode.|Production can not be executed.”
生产扣除模式上,计划生产枚数为0(无限值)|不能进行生产。
E500218 The last actual production number of sheets (%ld sheet) has exceeded production
schedulenumber of sheets (%ld sheet) at the time of continuation production.”
继续生产时,上一次实际生产数量(%ld)超过计划数量(%ld)|若要进行继续生产,请修改
计划生产数量。
E500219 The last actual production number of sheets (%ld sheet) has exceeded production schedule number
of sheets (%ld sheet) at the time of continuation production.”
重新生产时,上一次实际生产数量(%ld)超过计划数量(%ld)|若要进行重新生产,请修改
计划生产数量。
E500220 Device enable of setup does not match pick data
吸取数据和设置单元不匹配。
[Cause]
There is a Component or Pick data that is from a feeder which is not set 'to use' in the Setup.
[Treatment]
Please go to the Production Program Editor and see the Component and Pick data.
E500230 An error occurred in the checking prior to the production.|Production can not be executed.”
开始生产之前的检查发生错误,|不能进行生产
E500231 The warnings are over 100 issues in the checking prior to the production.|Production can not be
executed.”
开始生产之前的检查,发现 100 件以上的警告,|不能进行生产。
E500240 The head of the same number which can be used is not at a right and left station.|(There is both
head specification in the production program.)|Production cannot be executed.”
与可用 Head 同样编号的 Head,在左右站台上都不存在,|(在生产程序内已经指定两边
Head)|不能进行生产。
E500241 The head which can be used is not at a left station.|(There is left head specification in the
production program.)|Production cannot be executed.”
在左边站台上,不存在可以使用的 Head|(在生产程序内已经指定左边 Head)|不能进行生
产。
E500242 The head which can be used is not at a Right station.|(There is Right head specification in the
production program.)|Production cannot be executed.”
在右边站台上,不存在能使用的 Head|(在生产程序内已经指定右边 Head)|不能进行生
产。
E500243 Right and left OCC is unused.|(There is both head specification in the production
program.)|Production cannot be executed.”
没有使用左右 OCC|(在生产程序内已经指定两边 Head)|不能进行生产。
E500244 Left OCC is unused.|(There is left head specification in the production program.)|Production cannot
be executed.”
没有使用 OCC|(在生产程序内已经指定左边 Head)|不能进行生产。
E500245 Right OCC is unused.|(There is Right head specification in the production program.)|Production
cannot be executed.”
没有使用右 OCC|(在生产程序内已经指定右边 Head)|不能进行生产。
E500246 The station which it is a setup and is unused exists.|Production cannot be executed.(There is both
head specification in the production program.)
在设置中,站台被设置成不使用状态。|不能进行生产(在生产程序内已经指定两 Head)
E500247 It is a setup and a left station is unused.|Production cannot be executed.(There is left head
specification in the production program.)
在设置中,左站台被设置成不使用状态。|不能进行生产(在生产程序内已经指定左 Head)
E500248 It is a setup and a right station is unused.|Production cannot be executed.(There is Right head
specification in the production program.)
在设置中,右站台被设置成不使用状态。|不能进行生产(在生产程序内已经指定右 Head)
E500250 The head which can be used does not exist.|Production cannot be executed.”
不存在可用 Head|不能进行生产。
E500251 Because the OCC is unused, the mark recognition cannot be executed.|Production cannot be
executed.”
因没使 OCC,不能识别标记。|不能进行生产。
E500252 The station which can be used does not exist.(It is the setup data and both stations are
unused.)|Production cannot be executed.”
不存在可用站台。(在设置中,没有使用两边站) |不能进行生产。
E500253 The use nozzle is not in ATC.|Production cannot be executed.”
ATC 上不存在要使用的吸嘴。|不能进行生产。
E500260 There is no adjustment in setting the use unit.|Production cannot be executed.”
使用单元的设置不匹配。|不能进行生产。
E500261 The adsorption position is only at a left station.|(A left station (head or OCC or station) is
unused.)|Production cannot be executed.”
只有左边站台上,存在吸取位置|(没有使用左边站台的(HeadOCC 站台))|不能进行
生产。
E500262 The adsorption position is only at a right station.|(A right station (head or OCC or station) is
unused.)|Production cannot be executed.”
只有右边站台上,存在吸取位置|(没有使用右边站台的(HeadOCC 站台))|不能进行
生产。
E500263 The use nozzle is only at a left station.|(A left station (head or OCC or station) is
unused.)|Production cannot be executed.”
只有左边站台,存在可用吸嘴|(没有使用左边站台(HeadOCC,站 ))|不能进行生产。
E500264 The use nozzle is only at a right station.|(A right station (head or OCC or station) is
unused.)|Production cannot be executed.”
只有右边站台,存在可用吸嘴|(没有使用右边站台(HeadOCC 站台))|不能进行生产。
E500265 The adsorption position is only at a left station.|The use nozzle is not at a left station.|Production