JUKI贴片机错误代码集合.pdf - 第454页

" 在 %dth 程序中的图像 数据不完全。 " E6427 “ Specified number supplied in % dth program exceeds resource. “ " 在 % d t h 程序供给指定数量超过资源数。 " E6428 “ Assigned placement data in %dth program exi st in multiple stati on…

100%1 / 464
Complete the mounting data.
E6404 Component data is not completed.
"组件数据不完全。"
[Cause]
The part data where the mounting position is allocated is incomplete.
[Deal]
Complete the part data.
E6405 Pick data are incomplete.
"吸取数据不完全。"
[Cause]
The pick data is incomplete.
[Deal]
Complete the pick data.
E6406 Vision data is not completed.
"图像数据不完全。"
E6407 Specified number supplied exceeds resource.
"提供的特殊数字超过资源数。"
E6408 Assigned placement data exist in plural number of stations.
"指定贴片数据存在于复数位置。"
E6409 Assigned pick data exist in multiple stations.
"指定挑选数据存在于多个位置。"
E6420 Component in %dth program is overlapped with permanent component.
"%dth 程序中的组件被永久组件覆盖 "
E6422 PWB data in %dth program is not completed.
"在%dth 程序的基板 B 数据不完全。"
E6423 Placement data in %dth program is not completed.
"在%dth 程序的贴片数据不完全。"
E6424
Component data in %dth program is not completed.
"在%dth 程序的组件数据不完全。"
E6425 Pick data in %dth program is not completed.
"%dth 程序中的吸取数据不完全。"
E6426 Vision data in %dth program is not completed.
"%dth 程序中的图像数据不完全。"
E6427 Specified number supplied in %dth program exceeds resource.
" %dth程序供给指定数量超过资源数。"
E6428 Assigned placement data in %dth program exist in multiple stations.
"%dth 程序中的指定贴片数据存在于多个位置。"
E6429 Assigned pick data in %dth program exist in multiple stations.
"%dth 程序中的指定挑选数据存在于多个位置。"
E6440 The number of placemently resident nozzles exceeds the resource.
"固定吸嘴数量超过资源量。"
[Cause]
The number of the placement nozzles has exceeded the available number of resources.
[Deal]
Increase the number of nozzles specified in the MSL setup resource.
E6441 Number of permanent feeders exceeds resource.
"固定进料器数量超过资源量。"
E6442 %s over resource.
[Cause]
The number of feeders has exceeded the available number of resources.
[Deal]
Increase the number of feeders specified in the MSL setup resource.
E6450 Permanent data cannot be set.
"永久数据不能被设置。"
E6451 Protected data cannot be set.
"保护数据不能被设置。"
E6452
Production control data allocation failed.
"产品控制数据分配失败。"
E6453 Production condition data allocation failed.
"产品情况数据分配失败。"
E6454 Global fiducial data allocation failed.
"球型基准数据分配失败。"
E6455 Permanently resident nozzle allocation failed.
"永久的常驻的吸嘴分配失败。"
E6456 Permanently resident feeder allocation failed.
"永久的常驻的进料器分配失败。"
E6457 Already assigned pick data allocation failed.
"已经指定的挑选数据分配失败。"
E6458 A station to which pick data have already been assigned is excluded as an object of partition.
"已经被指定的选择数据位置作为区分目标被排除."
E6459 Already assigned placement data allocation failed.
"已经指定的贴片数据分配失败。"
E6460 The head corresponding to the already assigned placement data cannot be used.
"已分配给位置的相应的头没有使用"
[Cause]
Indicates that the station specified for the feeder in mounting and absorption data is different from the
allocated station.
[Deal]
Use the automatic selection to specify the station for the mounting data and absorption data for
optimization.
E6461 The already assigned placement data MTC cannot be used.
"不能使用已指定贴片数据 MTC"
E6462 Some pick data are designated in non-distrubutable station.
"不能设置已指定贴片数据吸嘴。"
[Cause]
Indicates that the data for the absorbing point specification has been already used for the occupation
data.
[Deal]
Use the automatic selection to specify the station for the mounting data and absorption data for
optimization.
E6463 Some placement data are designated in non-distributable station.
"已指定的贴片数据贴片层相互矛盾"
[Cause]
Indicates that the data for mounting specification is allocated for more than one station.
[Deal]
Use the automatic selection to specify the station for the mounting data and absorption data for
optimization.