JUKI贴片机错误代码集合.pdf - 第367页
“ 重新固定错误 : | 重新固定动作所需的移动距离不够长。 ” W650792 “ Reclamp error :| The state of th e WAIT sensor changed when the re-clamping operated .” “ 重新固定错误 : | 重新固定动作时,等待传感器状态已变更。 ” E651001 “ Returning to ORIGI N has not been done ” “ 未…
“基板固定错误 :|出口侧中心缓冲区没有被选用。”
W650701 “Reclamp error :| There is no PWB on the STOP sensor. | Please confirm the position of the PWB.”
“重新固定错误 :|在停止传感器上面,没有发现基板。|请确认一下基板位置。”
E650702 “Reclamp error :| The point of the PWB was not able to be detected.”
“重新固定错误 :|未查出基板前沿。”
E650703 “Reclamp error :| The point of the PWB was not able to be detected.”
“重新固定错误 :|未查出基板前沿。”
E650704 “Reclamp error :| The PWB is being clamped. | It is not possible to clamp again.”
“重新固定错误 :|基板处于固定状态。|不能重新固定。”
W650711 “Reclamp Error :| PWB was detected with the C.OUT sensor. | Please move PWB to the OUT
buffer”
“重新固定错误 :|C.OUT传感器发现基板。|请移走出口缓冲区的基板 “
W650731 “Reclamp error :| In buffer is no PWB on the STOP sensor. | Please confirm the position of the
PWB.”
“重新固定错误 :|入口侧中心缓冲区的停止传感器上,不存在基板。|请确认一下基板位置。”
E650732 “Reclamp error :| The point of the In buffer PWB was not able to be detected.”
“重新固定错误 :|未查出入口侧中心缓冲区的基板前沿。”
E650733 “Reclamp error :| The point of the In buffer PWB was not able to be detected.”
“重新固定错误 :|未查出入口侧中心缓冲区的基板前沿。”
E650734 “Reclamp error :| The PWB is being clamped. | It is not possible to clamp again.”
“重新固定错误 :|入口侧中心缓冲区的基板处于固定状态。|不能重新固定。”
W650761 “Reclamp error :| Out buffer is no PWB on the STOP sensor. | Please confirm the position of the
PWB.”
“重新固定错误 :|出口侧中心缓冲区的停止传感器上,不存在基板。|请确认一下基板位置。”
E650762 “Reclamp error :| The point of the Out buffer PWB was not able to be detected.”
“重新固定错误 :|未查出出口侧中心缓冲区的基板前沿。”
E650763 “Reclamp error :| The point of the Out buffer PWB was not able to be detected.”
“重新固定错误 :|未查出出口侧中心缓冲区的基板前沿。”
E650764 “Reclamp error :| The PWB is being clamped. | It is not possible to clamp again.”
“重新固定错误 :|出口侧中心缓冲区的基板处于固定状态。|不能重新固定。”
W650791 “Reclamp error :| There is not enough distance in the operation of the re-clamping.”
“重新固定错误 :|重新固定动作所需的移动距离不够长。”
W650792 “Reclamp error :| The state of the WAIT sensor changed when the re-clamping operated.”
“重新固定错误 :|重新固定动作时,等待传感器状态已变更。”
E651001 “Returning to ORIGIN has not been done”
“未完成返回原点。”
[Cause]
Returning to ORIGIN of Auto. PWB Width Alignment control has not been complete.
‧In order to adjust the Auto. PWB Width Alignment control, ORIGIN returning has to be done.
[Treatment]
‧Please complete the ORIGIN returning by pressing the ORIGIN button.
E651002 “An error occurred when returning to ORIGIN”
“返回原点发生错误。”
[Cause]
An error occurred while Auto. PWB Width Alignment control was returning to its ORIGIN.
[Treatment]
lease turn off the power supply of your machine and re-boot it. If the error occurs even after the
re-boot, please contact our technical service dept. for information.
E651003 “There is no need to move”
“没有必要移动。”
[Cause]
There is no need to adjust the Auto. PWB Width Alignment control since the board width got to the
required width already.
[Treatment]
E651004 “The traveling movement has discontinued due to Backup pin detection”
“被支撑台针检查而停止。”
[Cause]
The traveling movement got discontinued since the backup pin detecting sensor detected something
while the movement.
‧A backup pin was detected.
‧A conveying unit (Stopper pin unit, STOP C-OUT sensor unit, Outer shape X pusher unit)
interferes.
‧The installation position of the Backup pin detecting sensor is wrong.
‧The Backup pin detecting sensor is broken.
[Treatment]
‧If a cause of the abortion is a detected backup pin, please adjust a position of the backup pin.
‧If a cause of the abortion is an interference with a conveying unit, please adjust a position of the
conveying unit.
‧Please adjust the position of a unit that interferes.
‧Since the Backup pin detecting sensor has separated light emitter and light receiver. Therefore,
the sensor could be ON if the installation positions of the emitter and receiver are wrong. If there is
anything to interfere the sensor but the sensor is ON, you need to adjust the installation position of the
sensor.
Please examine the status of the sensor by adjusting the Auto. PWB Width Alignment control with
Manual control.
‧If the error still occurs even after all the treatments above were taken place, there is a possibility
that the sensor is broken. Please contact our technical service dept. for information.
E651005 “More than one command were tried to start at one time”
“命令被重复执行。”
[Cause]
Several commands to the Auto. PWB Width Alignment control device driver got started at one time.
[Treatment]
‧Please re-start the application.
‧Please re-install or version-up the application.
‧If the error still occurs even after all the treatments above were taken place, please contact our
technical service dept. for information.
E651006 “An error occurred while issuing command run event”
“起动命令事件出错。”
[Cause]
An error occurred inside the Auto. PWB Width Alignment control device driver.
‧An error occurred while issuing a command event.
[Treatment]
‧Please re-start the application.
‧Please re-install or version-up the application.
‧If the error still occurs even after all the treatments above were taken place, please contact our
technical service dept. for information.
E651007 “A time-out occurred while waiting for a command to be complete”
“执行命令超时。”
[Cause]
An error occurred inside the Auto. PWB Width Alignment control device driver.
‧A time-out error occurred while waiting for a command to be complete.
[Treatment]
‧Please re-start the application.
‧Please re-install or version-up the application.