JUKI贴片机错误代码集合.pdf - 第327页
Please remove the PWB from th e center Entrance station. W650213 “ PWB Conveying Error : A PWB has been detected on the center sta tion on t he Exit side. Please remove it ” “ 传送基板错误 : | 在出口侧中心缓冲区,发现基板。 | 请取下基板。 ” [Cause…
I650205 “Conveying Error : Please carry out the PWB on the Exit side station prior to the one on the Entrance
side station”
“传送基板错误 :|请先搬出出口缓冲区的基板。”
[Cause]
On the KE2030, a request of individual outlet conveying for the Entrance station was issued while
there was a PWB on the conveyor center Entrance/Exit station. This error occurs only at the PWB
conveying process(outlet conveying) that does not affect on a production.
[Treatment]
Please have a PWB on the center Exit station go first or have PWBs on both station go together.
E650208 “PWB Conveying Error :| Central motor Stop Check error.”
“传送基板错误 :|检查中心马达停止错误。”
[原因]
中心马达停止控制异常。作为原因,能考虑轴控制器基板的异常状态。
[解决]
关闭设备,关掉电源之后,请重新启动。
当以上的处理没有解决问题时,能考虑为轴控制基板的故障。
请与代理店或本公司技朮服务部取得联系。
W650209 “PWB Conveying Error : A PWB has been detected on the conveying route. Please remove it”
“传送基板错误 :|传送轨道上发现基板。|请取下基板。”
[Cause]
While conveying PWBs, an unexpected PWB was detected at the several buffers on the conveyor.
[Treatment]
Please remove the PWB from the conveyor.
W650211 “PWB Conveying Error : A PWB has been detected on the center station. Please remove it”
“传送基板错误 :|C.OUT传感器发现基板。|请移走出口缓冲区的基板。”
[Cause]
While conveying PWBs, an unexpected PWB was detected at the center station on the conveyor.
[Treatment]
Please remove the PWB from the center station.
W650212 “PWB Conveying Error: A PWB has been detected on the center station on the Entrance side.
Please remove it”
“传送基板错误 :|在入口侧中心缓冲区,发现基板。|请取下基板。”
[Cause]
While conveying PWBs on the KE2030, an unexpected PWB was detected at the center Entrance
station on the conveyor.
[Treatment]
Please remove the PWB from the center Entrance station.
W650213 “PWB Conveying Error : A PWB has been detected on the center station on the Exit side. Please
remove it”
“传送基板错误 :|在出口侧中心缓冲区,发现基板。|请取下基板。”
[Cause]
While conveying PWBs on the KE2030, an unexpected PWB was detected at the center Exit station
on the conveyor.
[Treatment]
Please remove the PWB from the center Exit station.
W650214 “PWB Conveying Error : A PWB has been detected on the OUT buffer. Please remove it”
“传送基板错误 :|在出口缓冲区,发现基板。|请取下基板。”
[Cause]
While conveying PWBs, an unexpected PWB was detected at the OUT buffer on the conveyor.
[Treatment]
Please remove the PWB from the OUT buffer.
E650218 “PWB Conveying Error :| Received resume originating command | in other condition of resume
temorary stop.”
“传送基板错误 :|不是恢复暂停状态,|却被接受恢复返回原点命令。”
W650219 “PWB Conveying Error : In operation of PWB conveying”
“传送基板错误 :|正在传送基板。”
[Cause]
A new request of PWB conveying was issued before a previous request of PWB conveying got
complete (Program error).
[Treatment]
Please see the error message, and remove all the PWBs on the conveyor. Then try the request again.
E650221 “PWB Conveying Error : Illegal input buffer motor movement. The process is forcibly terminated.
Please remove on the conveying route”
“传送基板错误 :|等待传感器OFF超时。”
[Cause]
Since IN sensor detected a PWB coming in, the belt of the INPUT buffer got started to drive and the
PWB was taken in to the INPUT buffer. However, the IN sensor did not get OFF after a certain
amount of time has passed. Usually, this error occurs when a PWB can not go through the INPUT
buffer for some reason.
[Treatment]
1 If the PWB was on the position where it is detected by IN sensor when the error occurred.
The PWB can not move for it got caught on the conveyor for some reason.
1) The PWB can not go through smoothly since the conveyor is not connecting well to the machine in
the upper part of the line. Please re-adjust the connection.
2) The conveyor width is not matching the PWB width. Please re-adjust the conveyor width.
3) The PWB you are trying to convey does not match the specifications of your machine. The
following cases do not match your machine.
‧A PWB with thickness of 0.3mm or less. Or a PWB with thickness of 4mm or more.
‧A PWB with mass of 2kg or more.
2 If the PWB was NOT on the position where it is detected by IN sensor when the error
occurred.
If the IN sensor does not get OFF when a PWB is properly being conveyed, there is a possibility that
the sensor is detecting something else. Please select [Manual Control] from the menu bar, and then
select [Control(C)] [Conveyor(C)] [Independent Control of Conveyor(I)] to see the status of IN sensor
in the 'Status' frame.
1) If there is anything that IN sensor reacts to underneath the IN sensor, please remove it from under
the sensor or change the position of the sensor.
2) If the treatment1 does not work, please adjust the sensitivity of the sensor, using the volume
control knob attached to the sensor.
3) If the treatment2 does not work, there is a possibility that the IN sensor is broken. It could be that
the wiring came out of the connector part, that a contact pin of the connector part is broken, that
wiring got cut off, or that sensor itself is broken. Please examine the wiring and the connector. If any
of them are broken, you need to replace them with new ones.
4) If the treatment3 does not work, a PCB is broken or the wiring between the PCBs is bad.
E650222 “PWB Conveying Error : PWB conveying error of Input buffer. The process is forcibly terminated.
Please remove on the conveying route”
“传送基板错误 :|入口传感器和等待传感器同时被检测时错误。 |请卸下基板。”
[Cause]
The belt of INPUT buffer got started to drive and a PWB was taken in to the INPUT buffer but the IN
sensor did not get OFF even if the WAIT sensor detected the PWB.
The PWB is taken in to the INPUT buffer and, if the WAIT sensor detects the PWB, the PWB
conveying stops and the PWB gets in a waiting mode. At this point, the IN sensor should not detect
anything.
[Treatment]
1 The PWB had been detected by WAIT and IN sensors when the error occurred.
1) The installation positions of IN and WAIT sensors are not correct. Please adjust the positions so
that the sensors do not detect anything at the same time.
2) The PWB you are trying to convey does not match the specifications of your machine. A machine
with M size specification can not deal with PWB that is over 330mm, a machine with L size
specification can not deal with PWB that is over 410mm, and a machine with E size specification can