JUKI贴片机错误代码集合.pdf - 第47页
[Treatment] Please turn on the power supply of MTS. E249008 “ The door of MTS opens ” “ MTS 门已打开 ” [Cause] Failed to draw the MTS tray ou t si nce the MTS door was open. [Treatment] Please close the MTS door. E249009 ” M…
E249001 “The origin point return is non-completion. Please operate again after completing the origin point
return”
“没有执行返回原点。|请执行返回原点后,再次操作。”
[Cause]
The axis has not yet been returned to home.
[Treatment]
Please perform the Return to home with ORIGIN switch.
E249002 “The OCC device is unused. The bank mark recognition is aborted”
“没有使用 OCC 设备。| 停止识别台架标记。”
[Cause]
OCC or OCC2 was set not to “Use” in the Use unit in Setup when performing the Bank mark
recognition.
[Treatment]
Please set OCC or OCC2 to “Use” in the Use unit in Setup.
E249003 “The stop key was pressed. The bank mark recognition is aborted”
“停止按钮被按下。| 停止识别台架标记。”
[Cause]
The stop key was pressed while the Bank mark recognition was in operation.
[Treatment]
“OK” button will completely abort the Bank mark recognition process.
E249004”The axis cannot be moved to recognition position. The bank mark recognition is aborted”
“轴不能移到识别位置。| 停止识别台架标记。”
[Cause]
An error occurred in the axis traveling.
[Treatment]
E249005 “The bank mark recognition error. The bank mark recognition is aborted”
“识别台架标记出错。| 停止识别台架标记。”
[Cause]
An error occurred in the Mark recognition by OCC unit.
[Treatment]
Please check and see if feeder bank is dirty or if something is concealing the feeder bank.
If the mark does not fit in the frame, you need to adjust the mark.
E249006 “MTS power off”
“MTS 电源被关闭。”
[Cause]
The power supply of MTS is off.
[Treatment]
Please turn on the power supply of MTS.
E249008 “The door of MTS opens”
“MTS 门已打开”
[Cause]
Failed to draw the MTS tray out since the MTS door was open.
[Treatment]
Please close the MTS door.
E249009 ”MTS offline”
“MTS 处于脱机状态”
[Cause]
MTS is not online.
[Treatment]
Please make MTS online.
E249010 “Servo is in the free state. The bank mark recognition is aborted”
[Cause]
The axis could not move since the servo was not locked.
[Treatment]
Please lock the servo using S-FREE switch.
Q249051 “Feeder bank has descended. Do you want to lift the feeder bank up and continue the bank mark
recognition?”
“送料器台架被下降。| 是否升高台架后,继续识别台架标记?”
[Cause]
The feeder bank had been descended when you tried to perform the Bank mark recognition.
[Treatment]
“YES” button will continue the Bank mark recognition process.
“NO” button will completely abort the Bank mark recognition process.
I249070 “Set online for MTS”
“设置的 MTS 没有联线”
[Cause]
Failed to draw the MTS tray out since the MTS was not online.
[Treatment]
Please make MTS online.
I249071 “Please close the door of MTS”
“请关闭 MTS 门”
[Cause]
Failed to draw the MTS tray out since the MTS door was open.
[Treatment]
Please close the MTS door.
E290000 “The origin point return is non-completion. | Please execute the teaching after the origin point
returns”
“没有执行原点返回。|请执行原点返回后,进行示教。”
[Cause]
Home returning has not been complete yet.
[Treatment]
Please press ORIGIN button to perform the Home returning, then try the teaching again.
E290001 “The OCC device is set in unused by the setup. | The teaching in the OCC device cannot be done”
“在设置中,OCC 装置没有被选用。”
[Cause]
OCC device is set to “not use” in the Use unit in Setup.
[Treatment]
If OCC is available, please set it to “use” in the Use unit in Setup. If not, this procedure cannot be
executed.
E290002 “The bad mark reader device is set in unused by the setup. | The teaching in the bad mark reader
device cannot be done”
”在设置中,识别坏板标记装置没有被选用。”
[Cause]
The Bad mark reader device is set to “not use” in the Use unit in Setup.
[Treatment]
If the Bad mark reader device is available, please set it to “use” in the Use unit in Setup. If not, this
procedure cannot be executed.
E290003 “The HMS device is set in unused by the setup. | The teaching in the HMS device cannot be done”
“在设置中,HMS 装置没有被选用。”
[Cause]
The HMS device is set to “not use” in the Use unit in Setup.
[Treatment]
If the HMS device is available, please set it to “use” in the Use unit in Setup. If not, this procedure
cannot be executed.
E290004 “The pick up point in the right feeder bank cannot be the teaching with a left device. Please use a
right device”