JUKI贴片机错误代码集合.pdf - 第55页

[Treatment] Please take the PWB off the inlet side of the buffer. E291016 “ PWB exist in the exit side cente r buffer. | Please execute retr y after ejection ” “ 出口缓冲处存在基板。 | 搬出出口处基 板后,再次执行。 ” [Cause] PWB loading did not…

100%1 / 464
width and the board size in Y direction.
[Treatment]
Please adjust the difference between the conveyor width and the board size in Y direction with a hand
knob, then try again.
E291011 Cannot move conveyor
不能移动传送幅宽。
[Cause]
This error occurs when the conveyor width cannot be adjusted for some reason. There is a possibility
that an obstruction is being detected by a sensor on the conveyor.
[Treatment]
Please make sure that there is no obstruction to be detected by sensors between the current position
and the destination.
E291012 The BOC mark recognition error [Circuit : %d / %d point]
识别 BOC 标记发生错误 [ 电路号 : %d / %d ]
[Cause]
VCS could not recognize the BOC mark(s).
1): Circuit number
2): The Xth BOC mark.
[Treatment]
There is a possibility that the BOC mark(s) could not be taught to the machine properly.
E291013 The area sensor was detected. Execution is aborted
发现位置错误。结束运行。
[Cause]
The process got forcibly aborted since the area sensor detected something.
[Treatment]
Please remove the factor that was detected by the sensor.
E291014 Emergency stopped. Execution is aborted
紧急停止状态。结束运行。
[Cause]
The process got forcibly aborted since the Emergency STOP occurred.
[Treatment.]
Please remove the cause of the Emergency STOP.
E291015 PWB exist in the entry side center buffer. | Please execute retry after ejection
入口缓冲处存在基板。|搬出入口处基板后,再次执行。
[Cause]
PWB loading did not succeed since a PWB is staying on the inlet side of the buffer.
[Treatment]
Please take the PWB off the inlet side of the buffer.
E291016 PWB exist in the exit side center buffer. | Please execute retry after ejection
出口缓冲处存在基板。|搬出出口处基板后,再次执行。
[Cause]
PWB loading did not succeed since a PWB is staying on the outlet side of the buffer.
[Treatment]
Please take the PWB off the outlet side of the buffer.
E291017 There is no completed pickup data
不存在已经完成的吸取数据。
[Cause]
The process could not be executed since there is no complete data.
[Treatment]
Please input and complete the pickup data.
E291018 Input string is mistake
字符串错误。
[Cause]
Character(s) was wrong when you hit the Enter key to define the caricature(s).
[Treatment]
Please re-enter characters.
E291019 Range is mistake
范围错误。
[Cause]
The value exceeded the input range when you hit the Enter key to define the value.
[Treatment]
Please enter a value which is within the input value.
E291020 Please check the feeder to trace
请检查要跟踪的送料器。
[Cause]
No feeders to trace are selected.
[Treatment]
Please select a feeder to trace.
E291021 There is no completed placement data
不存在已经完成的贴片数据。
[Cause]
This process could not be executed since there is no complete placement data.
[Treatment]
Please input and complete the placement data.
E291022 Because the one PWB is not clamped, cannot execute the BOC alignment
因为在上面没有固定基板,所以不能运行 BOC 校准。
[Cause]
Any PWBs are clamped on the conveyor buffer. If there is no PWB, BOC mark recognition is not
available.
[Treatment]
Please load PWB(s) to BOC align.
E291023 The automatic conveyor width adjustment is set in unused by the setup
在设置中,自动调整基板宽度没有被选用。
[Cause]
Auto. PWB Width Alignment Control is set to not use in Setup.
[Treatment]
If Auto. PWB Width Alignment Control is available, please set it to use in the Setup. If not, this
operation cannot be executed.
E291024 The BOC mark data send error [ID : &d]
BOC 标记信息发送失 [ ID : %d ]
[Cause]
BOC Mark data could not be sent to VCS.
[Treatment]
Please re-teach the Mark data to the machine.
E291025 Servo off, it is not possible to operation
因伺服被关闭, 不能运行
[Cause]
Servo is in the free state.
[Treatment]
Please perform the Home returning.
E291026 The PWB detected on conveyor. Please remove the PWB.”
请取下传送轨道上基板。
E291027 Can't execute the BOC alignment,because PWB clamp is non-completion.”
因为固定基板操作未结束,所以不能运 BOC 校准。
E291028 Device selection is mistake.”