the Maintenan ce manual. The hei ght change by self calibration o r MS parameter limits setters by the user level setting. 2. If the nozzle is not installed properly. Take the nozzle off once and rese t it on ATC. The fo…

100%1 / 464
loosen the speed controller of the slide plate driving cylinder.
B) The installation position of the slide plate ON/OFF sensor is wrong. There is a possibility that the
sensor gets ON before the slide plate fully opens/closes. Please re-adjust the sensor to where it gets
ON/OFF properly.
C) There is an obstruction that prevents the slide plate from being opened/closed. Please examine if
there is anything caught in near the slide plate.
D) The air supplying to the slice plate driving cylinder is not correct. Please examine if the air pipe is
properly connected.
E) The nut on the shaft of the slide plate driving cylinder is loose and the connector part of the slide
plate plays too much. Please examine if the nut is tightened up enough.
‧The ATC coordinates or the nozzle change height is not correct. If you change the coordinates or
the height, please select [Setup(S)] [MS parameter] and follow the Maintenance manual. For MS
parameter, it is limited that who can change the parameter by the user level setting.
E610039 The nozzle is too long (over 1.0mm). Please check the nozzle installation status
吸嘴过长。(超过 1.0mm)|请检查吸嘴。
[Cause]
When checking installation status after a nozzle is installed, the nozzle was detected at a position
where the nozzle is not supposed to be detected if it is installed properly. Possible causes are that
nozzles were changed manually, that the nozzle is not installed correctly, or that the window of the
laser measurement unit is dirty.
[Treatment]
1. If a nozzle of the right nozzle number is properly installed.
‧Although the nozzle has the right nozzle number, there is a possibility that a different nozzle was
installed manually. Please perform the ATC nozzle allocation and get the right nozzle length again.
The ATC nozzle allocation can be performed by selecting [Machine Setup] from the menu bar and
then [Setting Group(G)] [ATC Nozzle Allocation(A)].
‧There is a possibility that the measurement height of the laser sensor changed due to the filter
change or cleaning of the nozzle outer shaft (the installation part of a head). If the error occurs after
changing or cleaning a filter attached to the nozzle outer shaft, please examine if the filter is installed
correctly.
‧There is a possibility that the window of the laser sensor is dirty. Please clean the window of the
sensor. You can check the dirt of the window with the following procedures. Select [Manual Control]
from the menu bar, and then select [Control(C)] [Head(H)] [Laser Control(L)]. Select a concerned
laser sensor in 'Control' unit, and then select 'Image displaying' from 'Control Item' frame. By
enabling ON, an image data will be shown.
‧If the treatments above do not work, you need to change the laser measurement height. Please
select [Setup(S)] and then [Self-Calibration] [Setting Group(S)] [Laser sensor height(L)] to get the
laser height of the concerned head, or please select [MS Parameter] and change the height following
the Maintenance manual. The height change by self calibration or MS parameter limits setters by the
user level setting.
2. If the nozzle is not installed properly.
Take the nozzle off once and reset it on ATC. The following causes are possibly for why the nozzle
did not get installed properly.
‧There is oily stuff such as grease between the brim of the nozzle that touches ATC and the
installation side of ATC. If there is any oily stuff, please remove it.
‧There is an abnormal nozzle. Please examine if there is any obstructions on the installation part on
the head, or if it is damaged or deformed
‧The nozzle outer shaft (the installation part of a head) is not set correctly. Especially when the error
occurs after changing or cleaning a filter attached to the nozzle outer shaft, please examine if the
outer shaft is installed correctly.
‧Something is wrong with the movement of the ATC slide plate. In this case, the following cases
can be possible.
A) The speed controller of the slide plate driving cylinder is wrung to its minimum limit. Please
loosen the speed controller of the slide plate driving cylinder.
B) The installation position of the slide plate ON/OFF sensor is wrong. There is a possibility that the
sensor gets ON before the slide plate fully opens/closes. Please re-adjust the sensor to where it gets
ON/OFF properly.
C) There is an obstruction that prevents the slide plate from being opened/closed. Please examine if
there is anything caught in near the slide plate.
D) The air supplying to the slice plate driving cylinder is not correct. Please examine if the air pipe is
properly connected.
E) The nut on the shaft of the slide plate driving cylinder is loose and the connector part of the slide
plate plays too much. Please examine if the nut is tightened up enough.
‧The ATC coordinates or the nozzle change height is not correct. If you change the coordinates or
the height, please select [Setup(S)] [MS parameter] and follow the Maintenance manual. For MS
parameter, it is limited that who can change the parameter by the user level setting.
E610040 The nozzle is too short (over 10.0mm). Please check the nozzle
吸嘴过长。(超过 10.mm)|请检查吸嘴。
[Cause]
When checking installation status after a nozzle is installed, the nozzle was detected at a position
where the nozzle is not supposed to e detected if it is installed properly. A nozzle which is shorter
than a normal nozzle is installed.
[Treatment]
There is a possibility that the nozzle is damaged. Please examine the nozzle.
E610041 The nozzle width does not meet that of standard nozzle
不是标准吸嘴宽度。
[Cause]
The outer shape of auto-recognized nozzle did not coincide with that of the standard nozzle.
Therefore, nozzle number could not be et automatically. As a temporary nozzle number, the smallest
option nozzle number is set. The cause may be that a particular nozzle is set or that the window of the
laser sensor is dirty.
[Treatment]
1. If a particular nozzle is set.
If a nozzle number of the particular nozzle is the same as that of another particular nozzle that has
already been set, please re-enter the concerned nozzle number.
2. If a standard nozzle is set.
‧There is a possibility that the window of the laser sensor is dirty. Please clean the window of the
sensor. You can check the dirt of the window with the following procedures. Select [Manual Control]
from the menu bar, and then select [Control(C)] [Head(H)] [Laser Control(L)]. Select a concerned
laser sensor in 'Control' unit, and then select 'Image displaying' from 'Control Item' frame. By
enabling ON, an image data will be shown.
‧There is a possibility that something is on around the tip of the nozzle so that the right nozzle
width can not be detected. Please examine the nozzle.
‧If any of the treatments above do not apply and if you are sure that the nozzle is a standard nozzle,
please enter its nozzle number manually.
E610042 A shadow is detected while nozzle detection after returning nozzles
放回吸嘴后,检查吸嘴是否存在时发现阴影。
[Cause]
A nozzle was detected at a position where normal nozzles are not supposed to be detected in the
installation status checking which is performed after the nozzle returning. There is a possibility that
the nozzle could not be returned right or the window of the laser sensor is dirty.
[Treatment]
1. If the nozzle was returned properly
There is a possibility that the window of the laser sensor is dirty. Please clean the window of the
sensor. You can check the dirt of the window with the following procedures. Select [Manual Control]
from the menu bar, and then select [Control(C)] [Head(H)] [Laser Control(L)]. Select a concerned
laser sensor in 'Control' unit, and then select 'Image displaying' from 'Control Item' frame. By
enabling ON, an image data will be shown.
2. If the nozzle was not returned properly.
Please take the nozzle off the head part and set it on ATC. The following causes are possible for why
the nozzle could not be returned correctly.
‧There is an abnormal nozzle. Please examine if there is any obstructions on the installation part on
the head, or if it is damaged or deformed