JUKI贴片机错误代码集合.pdf - 第351页

1) Please turn off the power supply of you r machine and reboot it. 2) If the treatment1 does not work, please see if the wiring an d connectors in the XMP board are properly connected. 3) If the treatment2 does not work…

100%1 / 464
E650293 Clamp error : Backup plate of the center station on the Exit side went down illegally. The process is
forcibly terminated. Please remove on the conveying route
基板固定错误 :|出口侧中心缓冲区,支撑台下降失败。
[Cause]
The backup plate on the center station on the Exit side did not get down to the aimed clamp height.
This error usually occurs when there happens a mechanical hindrance to make the backup plate go
down.
[Treatment]
1. If the backup table on the center station on the Exit side was down when the error occurred.
An implement or component got caught between the PWB on the center station on the Exit side and a
frame or mechanism underneath it. Please examine if there is anything under the backup table.
2. Backup table went down at a high speed, and the continuous collision sound came out.
1) The encoder on the center station on the Exit side, that decides a position of PWB may be broken.
It could be that the wiring came off the connector part that a contact pin in the connector part is
broken, that wiring got cut off, or that the encoder itself is broken. Please examine that wiring and
connector part. If any of them are broken, you need to replace them with new ones.
2) There is a possibility that the screw that holds the encoder and the encoder axis on the center
station on the Exit side together is loose. Please examine if the screw is tightened up enough.
3) If the treatments above do not work, PCB is broken or the wiring between the PCBs is bad.
3. The motor made a noise but the backup table did not come down.
There is a possibility that the up-and-down motion system under the backup table that is on the center
station on the Exit side has a problem. The timing belt, the screw that holds a belt pulley, or the screw
that holds a motor may be loose. Please see if the each part is tightened up enough.
4. The backup table did not come down and the motor did not make any noise.
1) There is a possibility that the stepping motor is broken. It could be that the wiring came off the
connector part, that a contact pin in the connector part is broken, that the wiring got cut off, or that
motor itself is broken. Please examine the wiring and connector part. If any of them are broken, you
need to replace them with new ones.
2) If the treatment1 does not work, PCB is broken or the wiring between the PCBs is bad.
E650294 Clamp error : Time-out occurred while backup plate on the center station on the Exit side went
down. The process is forcibly terminated. Please remove on the conveying route
基板固定错误 :|出口侧中心缓冲区,支撑台下降超时。
[Cause]
The backup plate on the center station on the Exit side did not get to the aimed clamp height. As a
cause, there is a possibility that the firmware on the XMP board has a problem.
[Treatment]
The firmware on the XMP board to make the backup plate up and down is not under the control
mode.
1) Please turn off the power supply of your machine and reboot it.
2) If the treatment1 does not work, please see if the wiring and connectors in the XMP board are
properly connected.
3) If the treatment2 does not work, you need to change the XMP board to a new one.
E650295 Clamp error : Something is wrong with the backup motor movement on the center station on the
Exit side. The process is forcibly terminated. Please remove on the conveying route
基板固定错误 :|出口侧中心缓冲区,支撑台马达运转异常。
[Cause]
The backup plate on the center station on the Exit side did not get to the aimed clamp height. As a
cause, there is a possibility that the firmware on the XMP board has a problem.
[Treatment]
The firmware on the XMP board to make the backup plate up and down is not under the control
mode.
1) Please turn off the power supply of your machine and reboot it.
2) If the treatment1 does not work, please see if the wiring and connectors in the XMP board are
properly connected.
3) If the treatment2 does not work, you need to change the XMP board to a new one.
E650296 Clamp error : Hole reference process at the center station on the Exit side finished illegally. The
process is forcibly terminated. Please remove on the conveying route
基板固定错误 :|出口侧中心缓冲区,孔基准动作异常。
[Cause]
The backup plate got to the aimed clamp height but the Ref. pin sensor did not get ON. This error is
likely to occur when the Ref. pin did not get in the positioning hole correctly.
[Treatment]
1 The Ref. pin on the center station on the Exit side is not in the positioning hole correctly.
Please set the positions of the Ref. pin and the follower pin on the center station on the Exit side
correctly to the position of the Ref. hole. If you want to position PWBs with Outer shape Ref., please
make sure that Outer shape Ref.”
is enabled in the PWB data in the Program Editor.
2 The Ref. pin on the center station on the Exit side is in the positioning hole correctly.
Select [Manual Control] from the menu bar, and then select [Control(C)] [Conveyor(C)] [Independent
Control of Conveyor(I)] to see the status of Ref. pin sensor in the 'Status' frame. Select 'backup plate'
in the 'Control' item' on this screen to make the backup plate up and down. At this point, set the
Destination coordinates(up)(M) to -1.6mm.
1) When the Ref. pin sensor in the 'Status' frame does not get ON/OFF, there is a possibility that the
sensor is not installed properly. Please re-install the sensor to where it gets ON/OFF correctly.
2) When the Ref. pin sensor in the 'Status' frame does not get ON/OFF, there is a possibility that the
Ref. pin sensor is broken. It could be that the wiring came off the connector, that a contact pin in the
connector part is broken, that wiring got cut off, or that sensor itself is broken. Please examine the
wiring and the connector. If any of them are broken, you need to replace them with new ones.
3) When the Ref. pin sensor in the 'Status' frame does get ON/OFF, there is a possibility that the
signal line of the Ref. pin sensor is broken. It could be that the wiring came off the connector part,
that a contact pin in the connector part is broken, or that signal line got cut off. Please examine the
wiring and the connector. There also is another possibility that the screw that holds the encoder and
the encoder axis together is loose. Please make sure that the screw is tightened up enough.
4) If the treatments mentioned above do not work, a PCB is broken or the wiring between the PCBs is
bad.
E650297 Clamp Error :| Backup plate stopper of the center buffer | on the Exit side lock up illegally.”
基板固定错误 :|出口侧中心缓冲区,支撑台制动器固定错误。
E650298 Clamp Error :| Backup plate stopper of the center buffer | on the Exit side release illegally.”
基板固定错误 :|出口侧中心缓冲区,支撑台制动器释放错误。
W650309 Idle PWB Conveying Error : PWB is detected on the conveying route. Please remove it
传送基板(通过)错误 :|传送轨道上发现基板。
[Cause]
In the Idle PWB Conveying process, several buffers on the conveying route detected unexpected
PWBs on the conveying route.
[Treatment]
Please remove the PWBs on the conveyor.
W650311 Idle PWB Conveying Error : A PWB is detected on the center station. Please remove it
传送基板(通过)错误 :|中心缓冲区发现基板。
[Cause]
In the Idle PWB Conveying process, unexpected PWBs were detected on the center station on the
conveyor.
[Treatment]
Please remove the PWBs on the center station.
W650312 Idle PWB Conveying Error : A PWB is detected on the center station on the Entrance side. Please
remove it
传送基板(通过)错误 :|入口侧中心缓冲区发现基板。
[Cause]
In the KE2030 Idle PWB Conveying process, unexpected PWBs were detected on the center station
on the Entrance side on the conveyor.
[Treatment]
Please remove the PWBs on the center station on the Entrance side.