other. [Treatment] ‧Please turn off the power supply of your machi ne and reboot it . ‧If the error occurred after th e installati on or the version up of the software, you need t o re-install the software. ‧If the treat…
1.2 The 'Slide plate OFF sensor' in the 'Status' displaying frame does not get ON/OFF.
‧There is a possibility that the Slide plate OFF sensor was adjusted to out of the Cylinder's movable
range. Please re-adjust the sensor to where it gets ON/OFF.
‧If the treatment1 does not work, there is a possibility that the slide plate OFF sensor is broken. It
could be that the wiring came off the connector part, that a contact pin in the connector part is broken,
that the wiring got cut off, or that the sensor itself is broken. Please examine the wiring and connector.
If any of them are broken, you need to replace them with new ones.
‧If the treatment2 does not work, a PCB is broken or the wiring between the PCBs is bad.
2. Slide plate does not work.
‧There is a possibility that the lock valve of the solenoid valve, that drives the slide plate, is closed.
Please make sure that the lock valve of the solenoid valve is opened all the way.
‧There is a possibility that a nozzle is not installed in the ATC correctly and that prevent the slide
plate from sliding properly. Please see if nozzles are correctly installed in the ATC.
‧There is a possibility that a component or implement got caught in the sliding part of the slide plate
and that prevents the slide plate from sliding properly. Please see if there is anything on the slide
plate.
‧There is a possibility that the air supplying pipes to the slide plate driving cylinder have a problem.
It could be that the speed controller is fully tightened up, that the air pipe came off the cylinder, or a
wrong air pipe is connected to the cylinder. Please see the air pipes and make sure that correct pipes
are connected.
‧There is a possibility that the connecting part between the shaft of the slide plate driving cylinder
and the slide plate has a problem. It could be that the nut attached to the tip of the shaft fell off, that
the shaft got chipped or broken, or that the plate got chipped or broken. You need to have the
damaged part repaired or replace it with a new one.
‧There is a possibility that the slide plate driving cylinder is broken. Please stop the air supplying on
the machine and see if the slide plate works fine manually. If the plate does not work smoothly, you
need to replace it with a new one.
‧There is a possibility that the slide plate driving solenoid valve is broken. It could be that the
wiring came off the connector part, that a contact pin in the connector part is broken, that the wiring
got cut off, or the solenoid valve itself is broken. Please examine the wiring and connectors. If any of
them are broken, you need to replace them with new ones..
‧If the treatments mentioned above do not work, a PCB is broken or the wiring between the PCBs is
bad.
E610047 “The cylinder to which the nozzle is returned is not appropriate”
“放回吸嘴的圆筒位置不对。”
[Cause]
The ATC position to which a nozzle was requested to return is different from where the nozzle is
originally supposed to back. Some program versions in the machine may be clashing with each
other.
[Treatment]
‧Please turn off the power supply of your machine and reboot it.
‧If the error occurred after the installation or the version up of the software, you need to re-install
the software.
‧If the treatments above do not work, there is a possibility that MPX board(s) in the machine is
broken. You need to replace it(them) with new ones.
E610048 “Head kind is not defined”
“没有定义的 Head 种类。”
[Cause]
The head type is not correct. Some program versions in the machine may be clashing with each other.
[Treatment]
‧Please turn off the power supply of your machine and reboot it.
‧If the error occurred after the installation or the version up of the software, you need to re-install
the software.
‧If the treatments above do not work, there is a possibility that MPX board(s) in the machine is
broken. You need to replace it(them) with new ones.
E610049 “Laser sensor might be dirty. Please clean the sensor”
“激光传感器可能被弄脏。|请把传感器擦干净。”
[Cause]
A shadow was detected at a position where nothing is supposed to be detected if no nozzle has been
installed and nothing is wrong.
[Treatment]
There is a possibility that the window of the laser sensor is dirty. Please clean the window of the
sensor. You can check the dirt of the window with the following procedures. Select [Manual Control]
from the menu bar, and then select [Control(C)] [Head(H)] [Laser Control(L)]. Select a concerned
laser sensor in 'Control' unit, and then select 'Image displaying' from 'Control Item' frame. By
enabling ON, an image data will be shown.
E610050 “An error occurred in Nozzle posture detection”
“检查吸嘴姿势发生错误。”
[Cause]
A laser error occurred in the Nozzle posture detection by laser prior to a nozzle change.
[Cause]
There is a possibility that the laser recognition unit has a problem. You can check the abnormality of
the unit with the following procedures. Select [Manual Control] from the menu bar, and then select
[Control(C)] [Head(H)] [Laser Control(L)]. Select a concerned laser sensor in 'Control' unit, and then
select 'Image displaying' from 'Control Item' frame. By enabling ON, an image data will be shown. If
the data image does not appear at this point, please turn off the power supply of your machine and try
again. If the data image still does not get displayed after the retry, there is a possibility that the MCM
board in the laser sensor is not installed properly or that the sensor itself is broken. Please turn off the
power supply and examine the installation status of the MCM board in the sensor.
E610051 “The nozzle can not be returned since its posture is abnormal”
“因为吸嘴姿势不对,不能放回吸嘴。”
[Cause]
Nozzle returning got discontinued since a posture of the nozzle exceeded the permissive value during
the Nozzle posture checking by laser prior to a nozzle change.
[Treatment]
Please take the nozzle off manually. Please examine the installation status of a nozzle installed on the
head to find a cause of the error. Treatments to take vary, depending on whether nozzles are set in
the ATC properly or not.
1. If a nozzle rotated against its installation angle to ATC.
There is a possibility that the nozzle rotated during the production. The nozzle might be rotated
manually when the production stopped temporary.
Nozzle rotate every once in a while when a production is done for a long time (over a week) without
changing any nozzles.
If the nozzle rotation occurs during a few-hour production, there is a possibility that the nozzle is
abnormal. You need to replace the nozzle with a new one. If the error occurs regardless the nozzle
types, you need to replace a clamp part with a new one since it may be worn away.
2. If a nozzle did not rotate against its installation angle to ATC.
‧The nozzle shape is abnormal. Please examine if the green plastic part is chipped or not. Also,
please see if there is anything attached to the nozzle.
‧If the installation angle is slanting to a certain side, there is a possibility that the laser measurement
unit is not judging the angle correctly. In this case, the connecting cable between the laser
measurement unit and the servo driver may have a problem. Please take off the cable and re-install it.
‧If the error still occurs, there is a possibility that the MCM board in the laser sensor is not installed
properly or that the MCM board itself is broken. Please turn off the power supply of your machine
and check the installation status of the MCM board in the Laser recognition unit.
E610052 “ATC X coordinate is abnormal”
“X 坐标参数不正确。”
[Cause]
The head could not move to the specified ATC position. Some program versions in the machine may
be clashing with each other.
[Treatment]
‧Please turn off the power supply of your machine and reboot it.