JUKI贴片机错误代码集合.pdf - 第73页
Q302004 ” Error has occurred during noz zle installation. | Move to parkin g position? ” “ 安装吸嘴发生错误。 | 是否移到待命位 置? ” [Cause] A nozzle installation error of A TC nozzle allocation occurred. You are asked i f to move the he…
E301077 “IP address 0.0.0.0 is invalid.”
“ 0.0.0.0 是不正确的 IP 地址。 “
E301078 “The IP address contains blanks.”
“ IP 地址上有空格。 “
Q302000 “Reset I/O?”
“是否进行各 I/O 的安全方向设定?”
[Cause]
You are asked if to set each I/O in the safety direction.
[Treatment]
“YES” button will sets I/O in the safety direction.
“NO” button will discontinue to exit the Manual control.
Q302001”Exit machine setup. | Set value is saved?”
“退出机器设置。|是否保存设置?”
[Cause]
You are asked if to save the parameter that was set in Machine Setup.
[Treatment]
“YES” button will save the set value.
“NO” button will not save the set value.
“Cancel” button will cancel your inquiry.
Q302002 “Error has occurred during automatic measurement of nozzle. | Do you interrupt automatic
measurement?”
“吸嘴的自动测量发生错误。|是否停止自动测量?”
[Cause]
An error occurred during the auto. nozzle measurement of ATC nozzle allocation. You are asked if to
abort the following ATC auto. measurement.
[Treatment]
“YES” button will abort the auto. measurement.
“NO” button will continue the auto. measurement.
Q302003 ”Return to home has not yet been completed. | Return to home?”
“未完成原点返回。|是否进行原点返回?”
[Cause]
The axis has not returned to home yet. You are asked if to perform Home returning.
[Treatment]
“YES” button will perform the Home returning, and continue the process.
“NO” button will not perform the Home returning, but continue the process.
Q302004 ”Error has occurred during nozzle installation. | Move to parking position?”
“安装吸嘴发生错误。|是否移到待命位置?”
[Cause]
A nozzle installation error of ATC nozzle allocation occurred. You are asked if to move the head to
the nozzle removal position.
[Treatment]
“YES” button will move the head to the nozzle removal position, and continue the process.
“NO” button will not move the head to the nozzle removal position, but continue the process.
Q302005 “Extend shuttle?”
“是否取出滑梭?”
[Cause]
You are asked if to draw a shuttle out of MTC when teaching the MTC shuttle pick position to the
machine.
[Treatment]
“YES” button will draw the shuttle from MTC, and get in the teaching mode.
“NO” button will no draw the shuttle from MTC, but get in the teaching mode.
Q302006 “Do you interrupt automatic measurement?”
“是否停止自动测量?”
[Cause]
STOP switch was pressed while nozzle were automatically assigned. You are asked if to abort the
auto. measurement.
[Treatment]
“YES” button will abort the auto. measurement.
“NO” button will continue the auto. measurement.
Q302007 “A nozzle is fixed to %s. | Do you want to auto-return the nozzle?”
“吸嘴被装配在%s。 |是否自动放回吸嘴?”
[Cause]
With a nozzle on the head, the head in the Use unit was changed to “not use” from “use” You are
asked if to return the nozzle to ATC before enabling the change.
[Treatment]
“YES” button will return the nozzle installed on the head.
“NO” button will enable the change with the nozzle on the head. When you choose “NO”, you need
to cancel the nozzle allocation in the 'ATC nozzle allocation'.
Q302008 “Extend MTS mark?”
“是否获取 MTS 标记?”
[Cause]
In the MTS assemblage position offset, you are asked if to draw a bank mark from MTS when
teaching the mark position to the machine.
[Treatment]
“YES” button will draw the bank mark out.
“NO” button will not draw the bank mark out.
Q302009 “Vacuum Calibration has been set already. (ATC No:%s) | Would you like to disable the setting?”
“已经完成真空校准设置。(ATC No:%s)|是否取消原先设置?”
[Cause]
In the ATC nozzle allocation, you are asked if to disable the settings for current when you try to
specify a vacuum calibration to the current ATC even if the calibration unit has been set to another
ATC.
| Current Vacuum Calibration unit setting ATC No.
[Treatment]
“YES” button will disable the existing AT, and sets a vacuum calibration unit to the current ATC.
“NO” button will not do anything to the current ATC.
Q302010 “An error occurred during Auto. measuring nozzles. | Would you like to discontinue the Auto.
measuring on the left station?”
“吸嘴的自动测量发生错误。|是否停止左侧的自动测量?”
[Cause]
An error occurred on the left station during the auto. nozzle measurement of ATC nozzle allocation.
You are asked if to abort the following ATC Auto. measurement.
[Treatment]
“YES” button will abort the auto. nozzle measurement on the left station.
“NO” button will continue the auto. nozzle measurement on the left station.
Q302011 “An error occurred while installing nozzles. Would you like to move to the parking position? [Error
occurs] [Error No.] [Error Info.]”
“安装吸嘴发生错误。|是否移到等待位置?|| [错误发生] %5d| [错误 No.] %5d| [错误详细]
%5d||%s”
[Cause]
A nozzle installation error of ATC nozzle allocation occurred. You are asked if to move the head to
the nozzle removal position.
1): A code which shows where the error occurred
2): Error code
3): Error details code
[Treatment]
“Yes” button will move the axis to the nozzle removal position, and continue the process.
“NO” button will not move the axis to the nozzle removal position, but continue the process.