JUKI贴片机错误代码集合.pdf - 第228页

“ 发生 RT3 驱动警报。 ” [Cause] An abnormal matter happe ned to the Theta axis servo driver o n t he right head3. [Treatment] Please turn off the power supply of your machine. If the error occurs even after the reboot, please s…

100%1 / 464
Please turn off the power supply of your machine. If the error occurs even after the reboot, please see
if the cables are connected properly. If the error still occurs even when the cables are connected
properly, you need to replace the Theta axis servo driver on the left head2 with a new one.
E610238 LT3 Driver alarm occurred
发生 LT3 驱动警报。
[Cause]
An abnormal matter happened to the Theta axis servo driver on the left head3.
[Treatment]
Please turn off the power supply of your machine. If the error occurs even after the reboot, please see
if the cables are connected properly. If the error still occurs even when the cables are connected
properly, you need to replace the Theta axis servo driver on the left head3 with a new one.
E610239 LT4 Driver alarm occurred
发生 LT4 驱动警报。
[Cause]
An abnormal matter happened to the Theta axis servo driver on the left head4.
[Treatment]
Please turn off the power supply of your machine. If the error occurs even after the reboot, please see
if the cables are connected properly. If the error still occurs even when the cables are connected
properly, you need to replace the Theta axis servo driver on the left head4 with a new one.
E610240 RT1 Driver alarm occurred
发生 RT1 驱动警报。
[Cause]
An abnormal matter happened to the Theta axis servo driver on the right head1.
[Treatment]
Please turn off the power supply of your machine. If the error occurs even after the reboot, please see
if the cables are connected properly. If the error still occurs even when the cables are connected
properly, you need to replace the Theta axis servo driver on the right head1 with a new one.
E610241 RT2 Driver alarm occurred
发生 RT2 驱动警报。
[Cause]
An abnormal matter happened to the Theta axis servo driver on the right head2.
[Treatment]
Please turn off the power supply of your machine. If the error occurs even after the reboot, please see
if the cables are connected properly. If the error still occurs even when the cables are connected
properly, you need to replace the Theta axis servo driver on the right head2 with a new one.
E610242 RT3 Driver alarm occurred
发生 RT3 驱动警报。
[Cause]
An abnormal matter happened to the Theta axis servo driver on the right head3.
[Treatment]
Please turn off the power supply of your machine. If the error occurs even after the reboot, please see
if the cables are connected properly. If the error still occurs even when the cables are connected
properly, you need to replace the Theta axis servo driver on the right head3 with a new one.
E610243 RT4 Driver alarm occurred
发生 RT4 驱动警报。
[Cause]
An abnormal matter happened to the Theta axis servo driver on the right head4.
[Treatment]
Please turn off the power supply of your machine. If the error occurs even after the reboot, please see
if the cables are connected properly. If the error still occurs even when the cables are connected
properly, you need to replace the Theta axis servo driver on the right head4 with a new one.
E610244 XH Driver alarm occurred.”
发生 XH 驱动警报。
E610245 The power supply OFF of a VME bus occurred.”
发生 VME 的断电。
E610246 Power OFF occurred.”
发生停电。
E610247 XY limit occurred.”
发生 XY 超界
E610248 ZT limit occurred.”
发生 Zθ超界。
E610249 XY Driver alarm occurred.”
发生 XY 驱动警报。
E610300 An error occurred when ComRes command send
发送 COMRES 命令出错。
[Cause]
Command sending of Command-response type failed. This is an error that occurred during the data
communication in the machine.
[Treatment]
‧Please turn off the power supply of your machine and reboot it.
‧If the error occurred after the installation or the version up of the software, you need to re-install
the software.
‧If the treatments above do not work, there is a possibility that board(s) in the machine is broken.
You need to replace it(them) with new ones.
E610301 An error occurred when ComRes response receive
接受 COMRES 应答出错。
[Cause]
Response reception of Command-Response type failed. This is an error that occurred during the data
communication in the machine.
[Treatment]
‧Please turn off the power supply of your machine and reboot it.
‧If the error occurred after the installation or the version up of the software, you need to re-install
the software.
‧ If the treatments above do not work, there is a possibility that board(s) in the machine is broken.
You need to replace it(them) with new ones.
E610302 Z movement place parameter is not correct.”
Z 移动地点参数不正确。
E610303 T movement place parameter is not correct.”
T 移动地点参数不正确。
E610304 The timeout occurred in the waiting for an event.”
发生事件等待错误。
E610305 The error occurred in event issue.”
发生事件发行错误。
E610400 Vacuum of L1 head has been on
L1 Head 真空被打开。
[Cause]
A nozzle returning was requested while the vacuum of the left head1 is still ON. There is a possibility
that a component is being picked by the head.
Head1 的真空被启动的状态下要放回吸嘴。吸嘴上可能附有组件。
[Treatment]
Please take the component off the head, then turn off the vacuum before returning the nozzle.
检查 Head 有没有组件被贴上,如果真有组件被贴上,请取下 Head 上的组件。
E610401 Vacuum of L2 head has been on
L2 Head 真空被启动。
[Cause]