JUKI贴片机错误代码集合.pdf - 第97页
[Treatment] In the Production dialog, please sel ect a production mode that is NOT currently selected. E500214 “ Reference error from the Pick data to the Component data ” “ 从吸取数据到组件数据的参考错误 。 ” [Cause] The error appears …
E500208 “The production program breaks”
“生产程序被破坏。”
[Cause]
Failed to read in the production program file.
[Treatment]
This is a program error. Please make a note of the cause of the error and the error code, then contact
our technical service Dept. for information.
E500209 “A right and left number of positions where the BOC mark is completed recognition.”
“BOC 标记识别结束位置的左右个数不同。”
E500210 “Auto. Select exists in the Pick data. | Production can not be executed”
“吸取数据内存在自动选择,|不能执行生产。”
[Cause]
[Feed] in the Pick data is set to Auto. Select. The production can not be executed.
[Treatment]
You need either to execute the Optimization in the Production Program Editor or to set pick positions.
E500211 “There is no data which placement is specified”
“不存在指定的贴片数据。”
[Cause]
This message appears when the trial shot range is set to 'specified placement point' on the Trial
production dialog, but there is no placement data.
[Treatment]
Please select other trial shot range or go back to the Production Program Editor to examine the
Placement data.
E500212 “There is no pick point on both left and right sides in Fully Synchronized mode”
“或许是完全同时进行的生产程序,对应两个 Head 指定贴片数据上,不存在左右吸取点。”
[Cause]
There is a component which pick point exists only on one side.
[Treatment]
Please go to the Production Program Editor and see the Pick data.
E500213 “The program can not be produced in the <%s> Production mode”
“在生产模式<%s>上,不能生产的程序。”
[Cause]
The production can not be performed with the specified production mode.
Production mode
Input order
Optimization order
[Treatment]
In the Production dialog, please select a production mode that is NOT currently selected.
E500214 “Reference error from the Pick data to the Component data”
“从吸取数据到组件数据的参考错误。”
[Cause]
The error appears when the Pick data and Component data are broken.
[Treatment]
This is a program error. Please make a note of the cause of the error and the error code, then contact
our technical service Dept. for information.
E500215 “In the accumulative mode, the number of PWBs to be produced is the same as that of produced
PWBs. Production can not be executed”
“生产累加模式上,计划生产枚数和实际生产枚数相同,|不能进行生产。”
[Cause]
[accumulate the number of produced PWBs] is checked in the Operation option, and the number of
produced PWBs in the Production dialog already exceeded the number of PWBs to be produced.
Therefore, the production can not be started.
[Treatment]
Please re-set a number of PWBs to be produced that is bigger than the number of produced PWBs, or
disable [accumulate the number of produced PWBs] in the Operation option.
E500216 “The pick point does not exist on the station side for which the head is specified.”
“Head 被指定的站台侧,不存在吸取数据。”
E500217 “The number of sheets of the production schedule becomes '0' set (infinite the number of
sheets) in the subtraction mode.|Production can not be executed.”
“生产扣除模式上,计划生产枚数为”0”(无限值),|不能进行生产。”
E500218 “The last actual production number of sheets (%ld sheet) has exceeded production
schedulenumber of sheets (%ld sheet) at the time of continuation production.”
“继续生产时,上一次实际生产数量(%ld)超过计划数量(%ld)。|若要进行继续生产,请修改
计划生产数量。”
E500219 “The last actual production number of sheets (%ld sheet) has exceeded production schedule number
of sheets (%ld sheet) at the time of continuation production.”
“重新生产时,上一次实际生产数量(%ld)超过计划数量(%ld)。|若要进行重新生产,请修改
计划生产数量。”
E500220 “Device enable of setup does not match pick data”
“吸取数据和设置单元不匹配。”
[Cause]
There is a Component or Pick data that is from a feeder which is not set 'to use' in the Setup.
[Treatment]
Please go to the Production Program Editor and see the Component and Pick data.
E500230 “An error occurred in the checking prior to the production.|Production can not be executed.”
“开始生产之前的检查发生错误,|不能进行生产。”
E500231 “The warnings are over 100 issues in the checking prior to the production.|Production can not be
executed.”
“开始生产之前的检查,发现 100 件以上的警告,|不能进行生产。”
E500240 “The head of the same number which can be used is not at a right and left station.|(There is both
head specification in the production program.)|Production cannot be executed.”
“与可用 Head 同样编号的 Head,在左右站台上都不存在,|(在生产程序内已经指定两边
Head)|不能进行生产。”
E500241 “The head which can be used is not at a left station.|(There is left head specification in the
production program.)|Production cannot be executed.”
“在左边站台上,不存在可以使用的 Head,|(在生产程序内已经指定左边 Head)|不能进行生
产。”
E500242 “The head which can be used is not at a Right station.|(There is Right head specification in the
production program.)|Production cannot be executed.”
“在右边站台上,不存在能使用的 Head,|(在生产程序内已经指定右边 Head)|不能进行生
产。”
E500243 “Right and left OCC is unused.|(There is both head specification in the production
program.)|Production cannot be executed.”
“没有使用左右 OCC|(在生产程序内已经指定两边 Head),|不能进行生产。”
E500244 “Left OCC is unused.|(There is left head specification in the production program.)|Production cannot
be executed.”
没有使用左 OCC|(在生产程序内已经指定左边 Head),|不能进行生产。”
E500245 “Right OCC is unused.|(There is Right head specification in the production program.)|Production
cannot be executed.”
“没有使用右 OCC|(在生产程序内已经指定右边 Head),|不能进行生产。”
E500246 “The station which it is a setup and is unused exists.|Production cannot be executed.(There is both
head specification in the production program.)”
“在设置中,站台被设置成不使用状态。|不能进行生产(在生产程序内已经指定两边 Head)。
E500247 “It is a setup and a left station is unused.|Production cannot be executed.(There is left head