number is always larger than th e st arting component number. W241025 “ Measurement item is not selected ” “ 没有选择测定项目。 ” [Cause] Measurement cannot be performed s ince no measurement items are selected. [Treatment] Pleas…

100%1 / 464
[Treatment]
Please examine the Pick data.
E241019 A type of a stick feeder is not set up.”
没有指定管状送料器的类型。
E241020 There is no input character
没有输入字符。
[Cause]
There was no character when you hit the Enter key to define characters.
[Treatment]
Please enter characters.
E241021 Input character has irregularities
输入字符不正确。
[Cause]
The input characters were illegal when you hit the Enter key to define the characters.
[Treatment]
Please enter correct characters.
E241022 Input value exceeds predetermined data range. | (Data range : %s - %)
输入值超过输入范围。|(输入范围 : %s - %s)
[Cause]
The value when you hit the Enter key to define it exceeded the input range.
| input range
[Treatment]
Please enter a value that is within the input range.
E241023 Component size is too big
组件尺寸偏大。
[Cause]
Measurement/Inspection can not be performed since the component's size is too big.
[Treatment]
Please check the component's size.
E241024 The start no. is larger than the end no.”
开始号大于结束号。
[Cause]
The starting component number is larger than the ending component number.
[Treatment]
Please re-enter the starting or ending component number, and make sure that the ending component
number is always larger than the starting component number.
W241025 Measurement item is not selected
没有选择测定项目。
[Cause]
Measurement cannot be performed since no measurement items are selected.
[Treatment]
Please select necessary measurement items.
E241026 There is not a measurement possible component
要测定的组件不存在。
[Cause]
As a result of a search by measurement conditions, there is no component that can be measured.
[Treatment]
Please check the measurement(inspection) conditions.
W241027 The size relation of length and width does not agree with data.|width: %s ( %s ) length: %s ( %s )
|There is possibility that the setting of outline or direction are not fitting.”
测量组件大小的结果,组件的长宽被颠倒。|宽度: %s ( %s ) 长度: %s ( %s ) |组件供给角
度设置可能有错。
E241028 There is not a inspection possible component
要检查的组件不存在。
[Cause]
A result of a search by inspection conditions, there is no component that can be inspected.
[Treatment]
Please check the inspection conditions.
E241029 MTC is disable.”
不能使用 MTC
E241030 MTS is disable.”
不能使 MTS
E241031 The origin point return does not end.|Please retry after completing the origin point return.”
未结束返回原点。|返回原点结束后,请再次运行。
E241032 The servo motor is free.|Please retry after releasing the servo free state.”
伺服马达处于未起动状态。|请起动伺服马达后,再次运行。
E241033 The interrupt which was not able to operate was detected. | The processing is interrupted.”
查出不能运行的操作。|停止处理。
E241034 The area sensor was detected.| Please remove the sensor reaction factor.”
因范围不正常实施暂停。| 请查出原因并纠正。
E241035 The feeder float sensor was detected.| Please remove the sensor reaction factor.”
查出传送带浮动。|请纠正传送带浮动。
I241200 A continuous measurement ended
结束连续测量。
[Cause]
This message appears to inform you the end(interruption) of the continuous measurement.
[Treatment]
Please press the 'OK' button.
I241201 A continuous inspection ended
结束连续检查。
[Cause]
This message appears to inform you the end(interruption) of the continuous inspection.
[Treatment]
Please press the 'OK' button.
Q241300 Do you interrupt process?
是否中断处理?
[Cause]
You are asked if to abort the process when the STOP switch is pressed during the execution of the
process.
[Treatment]
'YES' button will abort the process.
'NO' button will continue the process.
Q241301 A noz. When calculated from the outline that measured and a noz. When at present is set up
differes. | A calculation noz. No. : %3d | A setting noz. No. : %3d | Does it renew a noz.? | When a
noz. Is renewed vacuum level is initialized
根据测量组件大小结果,算出的吸嘴号和当前使用的吸嘴号不相同|算出吸嘴号:%d|
置吸嘴号:%d|是否更新吸嘴号?(将初始化真空压)
[Cause]
A nozzle number calculated from the measured component outline and a nozzle number that is
specified in the Component data differs from each other. You are asked if to perform a nozzle change.
1): A nozzle number calculated from the measured component outline.
2): A nozzle number that is specified in the Component data
[Treatment]
'YES' button will change the nozzle number to a calculated nozzle number. At this point, [Vacuum