number is always larger than th e st arting component number. W241025 “ Measurement item is not selected ” “ 没有选择测定项目。 ” [Cause] Measurement cannot be performed s ince no measurement items are selected. [Treatment] Pleas…
[Treatment]
Please examine the Pick data.
E241019 “A type of a stick feeder is not set up.”
“没有指定管状送料器的类型。”
E241020 “There is no input character”
“没有输入字符。”
[Cause]
There was no character when you hit the Enter key to define characters.
[Treatment]
Please enter characters.
E241021 “Input character has irregularities”
“输入字符不正确。”
[Cause]
The input characters were illegal when you hit the Enter key to define the characters.
[Treatment]
Please enter correct characters.
E241022 “Input value exceeds predetermined data range. | (Data range : %s - %)”
“输入值超过输入范围。|(输入范围 : %s - %s)”
[Cause]
The value when you hit the Enter key to define it exceeded the input range.
| input range
[Treatment]
Please enter a value that is within the input range.
E241023 “Component size is too big”
“组件尺寸偏大。”
[Cause]
Measurement/Inspection can not be performed since the component's size is too big.
[Treatment]
Please check the component's size.
E241024 “The start no. is larger than the end no.”
“开始号大于结束号。”
[Cause]
The starting component number is larger than the ending component number.
[Treatment]
Please re-enter the starting or ending component number, and make sure that the ending component
number is always larger than the starting component number.
W241025 “Measurement item is not selected”
“没有选择测定项目。”
[Cause]
Measurement cannot be performed since no measurement items are selected.
[Treatment]
Please select necessary measurement items.
E241026 “There is not a measurement possible component”
“要测定的组件不存在。”
[Cause]
As a result of a search by measurement conditions, there is no component that can be measured.
[Treatment]
Please check the measurement(inspection) conditions.
W241027 “The size relation of length and width does not agree with data.|width: %s ( %s ) length: %s ( %s )
|There is possibility that the setting of outline or direction are not fitting.”
“测量组件大小的结果,组件的长宽被颠倒。|宽度: %s ( %s ) 长度: %s ( %s ) |组件供给角
度设置可能有错。
E241028 “There is not a inspection possible component”
“要检查的组件不存在。”
[Cause]
A result of a search by inspection conditions, there is no component that can be inspected.
[Treatment]
Please check the inspection conditions.
E241029 “MTC is disable.”
“不能使用 MTC。”
E241030 “MTS is disable.”
“不能使用 MTS。”
E241031 “The origin point return does not end.|Please retry after completing the origin point return.”
“未结束返回原点。|返回原点结束后,请再次运行。”
E241032 “The servo motor is free.|Please retry after releasing the servo free state.”
“伺服马达处于未起动状态。|请起动伺服马达后,再次运行。”
E241033 “The interrupt which was not able to operate was detected. | The processing is interrupted.”
“查出不能运行的操作。|停止处理。”
E241034 “The area sensor was detected.| Please remove the sensor reaction factor.”
“因范围不正常实施暂停。| 请查出原因并纠正。”
E241035 “The feeder float sensor was detected.| Please remove the sensor reaction factor.”
“查出传送带浮动。|请纠正传送带浮动。”
I241200 “A continuous measurement ended”
“结束连续测量。”
[Cause]
This message appears to inform you the end(interruption) of the continuous measurement.
[Treatment]
Please press the 'OK' button.
I241201 “A continuous inspection ended”
“结束连续检查。”
[Cause]
This message appears to inform you the end(interruption) of the continuous inspection.
[Treatment]
Please press the 'OK' button.
Q241300 “Do you interrupt process?”
“是否中断处理?”
[Cause]
You are asked if to abort the process when the STOP switch is pressed during the execution of the
process.
[Treatment]
'YES' button will abort the process.
'NO' button will continue the process.
Q241301 “A noz. When calculated from the outline that measured and a noz. When at present is set up
differes. | A calculation noz. No. : %3d | A setting noz. No. : %3d | Does it renew a noz.? | When a
noz. Is renewed vacuum level is initialized”
“根据测量组件大小结果,算出的吸嘴号和当前使用的吸嘴号不相同。|算出吸嘴号:%d|设
置吸嘴号:%d|是否更新吸嘴号?(将初始化真空压)”
[Cause]
A nozzle number calculated from the measured component outline and a nozzle number that is
specified in the Component data differs from each other. You are asked if to perform a nozzle change.
1): A nozzle number calculated from the measured component outline.
2): A nozzle number that is specified in the Component data
[Treatment]
'YES' button will change the nozzle number to a calculated nozzle number. At this point, [Vacuum