JUKI贴片机错误代码集合.pdf - 第60页

E292002 “ Registration number was exceeded ” “ 注册数已满,不能再注册。 ” [Cause] As the maximum number of regist ration is 100, you can not regi s ter any new data in the Mark Database. [Treatment] Please delete unnecessary marks o…

100%1 / 464
Q291507 The origin point return of automatic conveyor width adjustment is non-completion. Continue
anyway? | Please push 'No' when discontinue. 'Yes' when continuing
没有结束调整基版宽度的返回原点。是否执行返回原点?|执行前,请取下基板和摇把。
|执行,请按[]﹔停止,请按[]
[Cause]
You are asked if to perform the Home returning of the Auto. PWB Width Alignment Control since its
Home returning has not been complete yet.
[Treatment]
If you want to continue the operation, press 'yes'. If not, press 'No'.
Q291508 MTC Conveyor width is moved,too? | Please push 'No' when discontinue 'Yes' when continuing.”
是否也移动 MTC 装置的基板幅宽?|执行,请[]﹔停止,请按[]
I291509 Please set online for MTC.”
请联 MTC
Q291510 Conveyor width is moved. Does it move, although the vacuum table is attached? | Please push 'No'
when discontinue 'Yes' when continuing.”
虽然真空器已被安装,是否也移动基板幅宽?|执行,请按[]﹔停止,请按[]
E292000 No registered data
没有注册数据。
[Cause]
The following procedures were taken place when the number of the registered issue of Mark Database
is zero.
1. Press [Rename(C)] button or [Delete(D)] button on the Mark Database Management screen.
2. Press [Replace(A)] button on the Registration Mark Database screen.
3. Press [Copy(C)] button on the Vision Copy screen.
[Treatment]
The procedures above can not be performed when there is no registry in the Mark Database.
E292001 Please select the mark
请选择标记。
[Cause]
1. Although [Rename (C)] button or [Delete(D)] button screen were pressed on the Mark Database
Management screen, there is no selected mark to be an object of the action.
2. Although [Copy(C)] button was pressed on the Vision Copy screen, there is no selected mark to
be an object of the action.
[Treatment]
Please select a mark to be an object of each action.
E292002 Registration number was exceeded
注册数已满,不能再注册。
[Cause]
As the maximum number of registration is 100, you can not register any new data in the Mark
Database.
[Treatment]
Please delete unnecessary marks on the Mark Database Management screen.
E292003 The mark of the same registration name exists
已经存在同样注册名的标记。
[Cause]
1. On the Mark Data name change screen which is shown when pressing [Rename(C)] button on the
Mark Database Management screen, a name which was entered as a name after the change has
already been registered in the Mark Database.
2. When pressing [Add New(N)] button or [Replace(A)] button on the Registration Mark Database
screen, a name which was entered as a name to register has already been registered in the Mark
Database.
[Treatment]
Please enter the names that have not been registered in the Mark Database yet.
E292004 Please input the registration name
请输入注册名。
[Cause]
1. Although [OK] button was pressed on the Mark Data name change screen that is shown when
pressing [Rename(C )] button on the Mark Database Management screena name after the change
has not been entered yet.
1. 数据库管理画面上,单击[重新命名(C)]键显示标记数据名更改画面。在此画面上单
[确定]键,但没有输入“更改后的文件名”
2. Although [Add new(N)] button or [Replace(A)] button was pressed on the Mark Database
register screena name to register has not been entered yet.
2. 标记数据库注册画面上,单击[新建(N)][覆盖注册(A)]键时,没有输入“注册文件
名”
[Treatment]
Please enter a mark name.
请输入标记名。
E292005 Please select the registered area
请选择注册区域。
[Cause]
Although [Replace(A)] button was pressed on the Mark Database Registration screen, there is no
selected mark to be an object of the action.
标记数据库注册画面上,单击[覆盖注册(A)]键时,没有选择要覆盖的标记。
[Treatment]
Please select a mark to be an object of overwriting.
请选择要覆盖的标记。
E292006 The mark recognition type of the selected mark is different from setting the PWB data.”
被选标记的识别类型与基板数据上的设置不相同。
[原因]
标记识别种类为多值识别时,要复制二值化标记数据情况。
[解决]
请选择适当的标记数据。
E292007 The mark type is different from setting data.”
标记类型跟设置的类型不相同。
[原因]
粘贴复制数据领域的标记数据类型不同。
[解决]
请先删除标记数据,然后再复制标记数据。
Q292500 The mark data of a different L-R station is copied. Is it good though the recognition accuracy
decreases?
复制左右不同站点的标记数据,可是识别精度过低,是否继续?
Q292501 The selected mark data is deleted. Is it good?
是否删除被选定的标记数据?
[Cause]
This message appears in order to confirm you if to delete the data when pressing[Delete(D)] button on
the Mark Database Management screen.
[Treatment]
If you want to delete the mark, press [OK] button. If not, press [Cancel] button.
Q292502 The mark of the same registration name exists. Do you overwrite?
已经存在同样注册名的标记,是否覆盖保存?
第三章 机器设置