Please check the position of the Calibrat ion jig for laser alig nment, which is installed on the Calibration block. If the po sition is correct, the n something m ight be wrong wi th the vision unit . E906071 “ Calibrat…
set the VCS to “Use” in the Use unit setting in Machine Setup.
E906043 “%s is disable. Selected unit can not measure”
“%s是无效设备。|被选单元不能测量。”
[Cause]
The selected head is set to “not use” in the Use unit setting in Machine Setup.
[Treatment]
Please set the head to “use” in the Use unit setting in Machine Setup.
E906051 “No nozzle 501 or 502 are present in ATC. Add either nozzle using ATC setup”
“500号, 501号及502号吸嘴没有安装在ATC。|请利用机器设置的ATC吸嘴分配,设置吸嘴。”
[Cause]
501 nozzle and 502 nozzle have not been allocated to ATC. Please allocated a nozzle using the ATC
nozzle allocation in Machine Setup.
[Treatment]
Please assign 501 nozzle or 502 nozzle to ATC in the ATC nozzle allocation in Machine Setup.
E906052 “No nozzle 508 or 507 are present in ATC. Add either nozzle using ATC setup”
“508号及507号吸嘴没有安装在ATC。|请利用机器设置的ATC吸嘴分配,设置吸嘴。”
[Cause]
508 nozzle and 507 nozzle have not been allocated to ATC. Please allocated a nozzle using the ATC
nozzle allocation in Machine Setup.
[Treatment]
Please assign 507 nozzle or 508 nozzle to ATC in the ATC nozzle allocation in Machine Setup.
E906061 “Mark on calibration jig for laser alignment has not been acknowledged. Check the position of jig”
“不能识别激光校准用校准模具的标记。|请确认一下模具位置。”
[Cause]
The mark on the Calibration jig for laser alignment could not be recognized. The position at where
the Calibration jig has been set may be wrong or something is wrong with VCS.
[Treatment]
Please check the jig position and see if the jig is set to be able to see the first mark and second mark
illuminations of the Calibration block from the two holes on the jig. If the jig position is correct, then
something may be wrong with VCS.
E906062 “Mark on calibration jig for laser alignment has not been acknowledged”
“不能识别激光校准用校准模具的标记。”
[Cause]
The mark on the Calibration jig for laser alignment could not be recognized. The position at where
the Calibration jig has been installed may be wrong or something is wrong with the vision unit.
[Treatment]
Please check the position of the Calibration jig for laser alignment, which is installed on the
Calibration block. If the position is correct, then something might be wrong with the vision unit.
E906071 “Calibration jig for laser alignment has not been picked up. Check that jig is placed on calibration
jig”
“不能吸取激光校准用校准模具。|请确认一下模具是否置于校准块上面。”
[Cause]
Failed to pick up the Calibration jig for laser alignment. An Out-of-component error occurred in the
Laser recognition of the Calibration jig for laser alignment.
[Treatment]
Please check and see if the Calibration jig for laser alignment is placed on the Calibration block.
E906072 “Calibration jig for laser alignment has not been picked up. Check that jig is placed on jig station”
“不能吸取激光校准用校准模具。|请确认一下模具是否置于模具站点上面。”
[Cause]
Failed to pick up the Calibration jig for laser alignment. An out-of-component error occurred in the
Laser recognition of the Calibration jig for laser alignment.
[Treatment]
Please check and see if the Calibration jig for laser alignment is placed on the Calibration station.
E906073 “Error between the locations of jig placed and calibration block exceeds limit value. Check the MS
parameter”
“模具的贴片位置和校准块位置的误差超过界限值。|请检查一下MS参数。”
[Cause]
After measuring the assemblage position offset of a head, the Calibration jig for laser alignment was
placed on the center of the Calibration block.. The placement position deviated from the Calibration
block by more than 1.
[Treatment]
System error
Please check the MS parameter.
E906074 “Position of calibration jig for laser alignment has irregularities. Check the position of jig”
“激光校准用校准模具的位置有些异常。|请确认一下模具位置。”
[Cause]
The position of the Calibration jig for laser alignment on the Calibration block is irregular.
The center of the recognized mark is more than 0.5mm far from the center of the Calibration block..
[Treatment]
Please place the jig to make the recognized mark 'circular'.
E906075 “Calibration jig for VCS has not been picked up. Check that jig is placed on jig station”
“不能吸取VCS用校准模具。|请确认一下模具是否置于模具站点上面。”
[Cause]
Failed to pick up the Calibration jig for VCS. An out-of-component error occurred in the Laser
recognition of the Calibration jig for VCS.
[Treatment]
Please check and see if the Calibration jig for laser alignment is placed on the Calibration station.
E906101 “Error has occurred when detecting height of measuring plane of laser | code:%ld”
“检测激光测量高度发生错误。|代码: %ld”
[Cause]
An error occurred when measuring the height by laser.
1: Error code
2: The shadow does not get clear when lifting Z axis up.
3: There is not shadow when lowering Z axis down.
4: After detecting a shadow once, Z axis was lifted up but thshadow does not get clear.
5: A communication error occurred.
6: An axis error occurred.
[Treatment]
Something may be wrong with the Laser alignment. Please check the Laser alignment.
E906102 “Error has occurred during laser measurement(ONCE) | code:%ld”
“设置激光参数发生错误。|代码: %ld”
[Cause]
An abnormal matter happened in the Parameter setting of Laser.
1): Error code.
2): A communication error occurred.
[Treatment]
Please contact our technical service dept. for information.
E906103 “Error has occurred during laser measurement(ONCE) | code:%ld”
“激光测量(ONCE)发生错误。|代码: %ld”
[Cause]
An error occurred during the measurement (ONCE) by laser.
1): Error code.
2): A communication error.
[Treatment]
Please contact our technical service dept. for information.
E906104 “Error has occurred during laser measurement (SWEEP) | code:%ld”
“激光测量(SWEEP)发生错误。|代码: %ld “
[Cause]