E6464 Already assigned placement data c hip standing ca nnot be detecte d. " 不能检测到已指定贴片数据的固定 芯片站立。 " [Cause] Indicates that the number of t he mount ing positions has exceede d the maximum value, i.e., checking…

100%1 / 464
"永久的常驻的吸嘴分配失败。"
E6456 Permanently resident feeder allocation failed.
"永久的常驻的进料器分配失败。"
E6457 Already assigned pick data allocation failed.
"已经指定的挑选数据分配失败。"
E6458 A station to which pick data have already been assigned is excluded as an object of partition.
"已经被指定的选择数据位置作为区分目标被排除."
E6459 Already assigned placement data allocation failed.
"已经指定的贴片数据分配失败。"
E6460 The head corresponding to the already assigned placement data cannot be used.
"已分配给位置的相应的头没有使用"
[Cause]
Indicates that the station specified for the feeder in mounting and absorption data is different from the
allocated station.
[Deal]
Use the automatic selection to specify the station for the mounting data and absorption data for
optimization.
E6461 The already assigned placement data MTC cannot be used.
"不能使用已指定贴片数据 MTC"
E6462 Some pick data are designated in non-distrubutable station.
"不能设置已指定贴片数据吸嘴。"
[Cause]
Indicates that the data for the absorbing point specification has been already used for the occupation
data.
[Deal]
Use the automatic selection to specify the station for the mounting data and absorption data for
optimization.
E6463 Some placement data are designated in non-distributable station.
"已指定的贴片数据贴片层相互矛盾"
[Cause]
Indicates that the data for mounting specification is allocated for more than one station.
[Deal]
Use the automatic selection to specify the station for the mounting data and absorption data for
optimization.
E6464 Already assigned placement data chip standing cannot be detected.
"不能检测到已指定贴片数据的固定芯片站立。"
[Cause]
Indicates that the number of the mounting positions has exceeded the maximum value, i.e., checking
the occupation data was failed.
[Deal]
Decrease the number of mounting positions.
E6465 Already assigned placement data chip standing cannot be detected.
[Cause]
Indicates that inconsistency was found in the layer specification.
[Deal]
Reset the layer allocation for optimization.
E6500 Data cannot be assigned to machine station.
"数据不能被指定到机器位置。"
E6550 Failed to distribute data.
"没有%d 数据能被指定到机器位置。"
[Cause]
An invalid data was found during data allocation for the mounting or absorption list. (See the sub-list
for details.)
(Detailed messages corresponding to each station.)-Unavailable for specification since it is an
applicator. Type 770 or 775 station.
-Unavailable for dividing destinations. Station with the balance option check is disabled or 0 balance.
-MTC is disabled. Station unavailable for using MTC.
-MTS is disabled. Station unavailable for using MTS.
-Chip standup-detection is disabled. Station unavailable for chip-standup inspection.
-Coplanarity inspection is disabled. Station unavailable for coplanarity inspection.
-The verification is disabled. Station unavailable for the verification.-IC mark part is disabled. Station
unavailable for IC mark.
-Tray-holder is disabled. Type 770 or 775station.
-Nozzle 5 is disabled. Type 770 or 775 station.
-44 and 56 mm feeders are disabled. Type 770 or 775 station.
-The value specified for the outside dimension deviates from the range and not acceptable. Outside
dimension applied to the centering is out of the range.
-The value specified for the part height deviates from the range and not acceptable. Height applied to
the centering is out of the range.-Every head is disabled. Station with all heads disabled.
-General-purpose head is disabled. Station unavailable for general-purpose head.
-IC head is disabled. Station unavailable for IC head.
-LAIC head is disabled. Station unavailable for LAIC head.
-Specified centering is disabled. Station unavailable for the centering specified.
-Vision centering is disabled. Station unavailable for vision centering.
-ATC has no free space Station having no space for nozzle allocation via optimization.-Placement
nozzle is not used Station with no placement nozzle specified.
-Nozzle resource is insufficient Resource for used nozzle is insufficient.
-Mounting data for layer 1 cannot be allocated Station unavailable for layer 1 allocation with
multi-layer mounting data.
-Mounting data for layer 2 cannot be allocated Station unavailable for layer 2 allocation with
multi-layer mounting data.
-Mounting data for layer 3 cannot be allocated Station unavailable for layer 3 allocation with
multi-layer mounting data.-There is no free space to be allocated. Station having no space for the data
to be absorbed that can be allocated only to the specified station.
-The mounting data has been fully specified. Station with which 2000 or more data were allocated.
-The maximum number of the mounting data has been specified. Station with which 50 or more data
were allocated.
-The maximum number of MTCs has been specified. Station with which 20 or more data were
allocated.
-The maximum number of MTSs has been specified. Station with which 40 or more data pieces were
allocated-The maximum number of the tray-holders has been specified. Station with which 20 or
more data (for 730, 740, 750 and 760), or 5 or more data (for 720) were allocated.
-A value specified deviates from the range. Station whose data specified for absorption deviates from
the area option range.
-The specified data overlaps the range for installing the IC recycle belt. IC recycle belt overlaps the
absorption data.
-The data specified overlaps the range for installing the placement part. Placement part overlaps the
absorption data.-The absorbing positions specified part overlap one another. The absorbing positions
specified part overlap one another.
E6551 Failed to distribute data.
[Cause]
An invalid data was found during data allocation for the mounting or absorption list. (See the sub-list
for details.)
(Detailed messages corresponding to each station)-Unavailable for specification since it is an
applicator. Type 770 or 775 station
-Unavailable for dividing destinations. Station with the balance option check is disabled or 0 balance
-MTC is disabled. Station unavailable for using MTC
-MTS is disabled. Station unavailable for using MTS.