E650256 “ PWB Conveying Erro r :| C.OUT2 sens or ON detecti on error at Cent er stopper ON. ” “ 传送基板错误 : | 中心 STOP ON 时,发现 C.OUT2 传感器 ON 错误。 ” E650257 “ PWB Conveying Erro r :| STOP2 sen sor ON detection error at Cente r…
even though a certain amount of time has passed since the C-OUT sensor on the center station on the
Entrance side got OFF when conveying a PWB on the center station on the Entrance side to the center
station on the Exit side. Usually, this error occurs when a PWB can not go through conveyor for some
reason.
[Treatment]
1 f the PWB is on the position where it is NOT detected by C-OUT sensor on the Entrance side
station and STOP sensor on the Exit side station when the error occurred.
The PWB can not move for it got caught on the conveyor for some reason.
1) The conveyor width is not matching the PWB width. Please re-adjust the conveyor width.
2) The PWB you are trying to convey does not match the specifications of your machine. The
following cases do not match your machine.
‧A PWB with thickness of 0.3mm or less. Or a PWB with thickness of 4mm or more.
‧A PWB with mass of 2kg or more.
2 The error occurred since the stopper on the center station on the Entrance side came up and
prevented the PWB from going through the center station.
The error occurs if the C-OUT sensor on the Entrance side gets temporarily OFF before the PWB has
gone through the station.
1) The error occurs if the C-OUT sensor on the Entrance side gets temporarily OFF when the PWB
has gone through the station because the PWB has holes on it or the edge of the PWB is chipped.
Please select [Setup(S)] [Setup(S)] from the menu bar, and then select [Setting Group(G)] [PWB
conveyor(C)]. Set 'Delay for conveyor sensor' to disable the holes or chips on PWBs.
2) The error occurs if C-OUT sensor temporarily gets OFF because the PWB has a part that fully
reflects. This error is likely to occur when you use boards such as metal jig board. As a treatment,
please set 'Delay for conveyor sensor', following the steps mentioned in the treatment1.
3 If the belt was moving for a while after the PWB touched the stopper on the center station on
the Exit side when the error occurred.
The STOP sensor on the center station on the Exit side is not detecting the PWB. Please
select[Manual Control] from the menu bar, and then select [Control(C)] [Conveyor(C)] [[Independent
Control of Conveyor(I)] to see the status of STOP sensor in the 'Status' frame.
1) The sensitivity of the STOP sensor on the center station on the Exit side may be too low. Please
re-adjust the sensitivity of the sensor, using the volume control knob attached to the sensor.
2) If the treatment1 does not work, there is a possibility that the STOP sensor on the center station on
the Exit side is broken. It could be that the wiring came off the connector part, that a contact pin in
the connector part is broken, that wiring got cut off, or that sensor itself is broken. Please examine the
wiring and the connector. If any of them are broken, you need to replace them with new ones.
3) If the treatment2 does not work, a PCB is broken or the wiring between the PCBs is bad.
E650255 “PWB Conveying Error :| C.OUT2 sensor ON detection time out error.”
“传送基板错误 :|C.OUT2传感器ON超时。”
E650256 “PWB Conveying Error :| C.OUT2 sensor ON detection error at Center stopper ON.”
“传送基板错误 :|中心STOP ON时,发现C.OUT2传感器ON错误。”
E650257 “PWB Conveying Error :| STOP2 sensor ON detection error at Center stopper ON.”
“传送基板错误 :|中心STOP ON时,发现STOP2传感器ON错误。”
E650261 “PWB Conveying Error :| PWB conveying time out error of OUT buffer.”
“传送基板错误 :|OUT缓冲区搬出基板超时。”
E650262 “PWB Conveying Error : PWB conveying error of Output buffer. The process is forcibly terminated.
Please remove on the conveying route”
“传送基板错误 :|OUT传感器OFF超时。”
[Cause]
The error occurs when letting a PWB on the OUT buffer go based on a PWB request signal sent from
a machine in the lower part of the line, but the OUT sensor does not get OFF after a certain amount of
time has passed since the sensor got OFF and then ON again.
[Treatment]
1 If the PWB was on the position where it is detected by OUT sensor when the error occurred.
The PWB can not move for it got caught on the conveyor for some reason.
1) The PWB can not go through smoothly since the conveyor is not connecting well to the machine in
the lower part of the line. Please re-adjust the connection.
2) The conveyor width is not matching the PWB width. Please re-adjust the conveyor width.
3) The PWB you are trying to convey does not match the specifications of your machine. The
following cases do not match your machine.
‧A PWB with thickness of 0.3mm or less. Or a PWB with thickness of 4mm or more.
‧A PWB with mass of 2kg or more.
2 If the PWB was NOT on the position where it is detected by OUT sensor when the error
occurred.
If the OUT sensor does not get OFF when a PWB is properly being conveyed, there is a possibility
that the sensor is detecting something else. Please select [Manual Control] from the menu bar, and
then select [Control(C)] [Conveyor(C)] [Independent Control of Conveyor(I)] to see the status of
OUT sensor in the 'Status' frame.
1) If there is anything that OUT sensor reacts to underneath the OUT sensor, please remove it from
under the sensor or change the position of the sensor.
2) If the treatment2 does not work, please adjust the sensitivity of the sensor, using the volume
control knob attached to the sensor.
3) If the treatment2 does not work, there is a possibility that the IN sensor is broken, It could be that
the wiring came off the connector part, that a contact pin in the connector part is broken, that wiring
got cut off, or that sensor itself is broken. Please examine the wiring and the connector. If any of them
are broken, you need to replace them with new ones.
4) If the treatment3 does not work, a PCB is broken or the wiring between the PCBs is bad.
E650264 “PWB Conveying Error : PWB conveying time out error of Output buffer. The process is forcibly
terminated. Please remove on the conveying route”
“传送基板错误 :|从中心缓冲区到出口缓冲区,基板移动超时。”
[Cause]
The OUT sensor on the Output buffer did not get ON although a certain amount of time has passed
since the C-OUT sensor on the center station got OFF when conveying the PWB on the center station
in to the Output buffer. Usually, this error occurs when a PWB can not go through the Output buffer
for some reason.
[Treatment]
1 If the PWB is on the position where it is NOT detected by the C-OUT sensor on the center
station or the OUT sensor on the Output buffer.
The PWB can not move for it got caught on the conveyor for some reason.
1) The PWB can not go through smoothly since the conveyor is not connecting well to the machine in
the upper part of the line. Please re-adjust the connection.
2) The PWB you are trying to convey does not match the specifications of your machine. The
following cases do not match your machine.
‧A PWB with thickness of 0.3mm or less. Or a PWB with thickness of 4mm or more.
‧A PWB with mass of 2kg or more.
2 he error occurred since the stopper came up and prevented the PWB from going through the
conveyor when conveying the PWB out from the center station.
The error occurs if the C-OUT sensor gets temporarily OFF before the PWB has gone out of the
station.
1) The error occurs if the C-OUT sensor gets temporarily OFF before letting the PWB go because
the PWB has holes on it or the edge of the PWB is chipped. Please select [Setup(S)] [Setup(S)] from
the menu bar, and then select [Setting Group(G)] [PWB conveyor(C)]. Set 'Delay for conveyor sensor'
to disable the holes or chips on PWBs.
2) The error occurs if C-OUT sensor temporarily gets OFF because the PWB has a part that fully
reflects. This error is likely to occur when you use boards such as metal jig board. As a treatment,
please set 'Delay for conveyor sensor', following the steps mentioned in the treatment1.
3 If the belt was moving for a while after the PWB got to the OUT sensor position when the error
occurred.
The OUT sensor is not detecting the PWB. Please select[Manual Control] from the menu bar, and
then select [Control(C)] [Conveyor(C)] [[Independent Control of Conveyor(I)] to see the status of
STOP sensor on the center station on the Exit side in the 'Status' frame.
1) The sensitivity of the OUT sensor on the center station on the Exit side may be too low. Please
re-adjust the sensitivity of the sensor, using the volume control knob attached to the sensor.
2) If the treatment1 does not work, there is a possibility that the OUT sensor on the center station on