JUKI贴片机错误代码集合.pdf - 第328页

1) The PWB can not go through smoothly si nce the conveyor is no t connecting well to the machine in the upper part of the line. Pleas e re-adjust the connection. 2) The conveyor width is not matchi ng the PWB width. Ple…

100%1 / 464
Please remove the PWB from the center Entrance station.
W650213 PWB Conveying Error : A PWB has been detected on the center station on the Exit side. Please
remove it
传送基板错误 :|在出口侧中心缓冲区,发现基板。|请取下基板。
[Cause]
While conveying PWBs on the KE2030, an unexpected PWB was detected at the center Exit station
on the conveyor.
[Treatment]
Please remove the PWB from the center Exit station.
W650214 PWB Conveying Error : A PWB has been detected on the OUT buffer. Please remove it
传送基板错误 :|在出口缓冲区,发现基板。|请取下基板。
[Cause]
While conveying PWBs, an unexpected PWB was detected at the OUT buffer on the conveyor.
[Treatment]
Please remove the PWB from the OUT buffer.
E650218 PWB Conveying Error :| Received resume originating command | in other condition of resume
temorary stop.”
传送基板错误 :|不是恢复暂停状态,|却被接受恢复返回原点命令。
W650219 PWB Conveying Error : In operation of PWB conveying
传送基板错误 :|正在传送基板。
[Cause]
A new request of PWB conveying was issued before a previous request of PWB conveying got
complete (Program error).
[Treatment]
Please see the error message, and remove all the PWBs on the conveyor. Then try the request again.
E650221 PWB Conveying Error : Illegal input buffer motor movement. The process is forcibly terminated.
Please remove on the conveying route
传送基板错误 :|待传感器OFF超时。
[Cause]
Since IN sensor detected a PWB coming in, the belt of the INPUT buffer got started to drive and the
PWB was taken in to the INPUT buffer. However, the IN sensor did not get OFF after a certain
amount of time has passed. Usually, this error occurs when a PWB can not go through the INPUT
buffer for some reason.
[Treatment]
1 If the PWB was on the position where it is detected by IN sensor when the error occurred.
The PWB can not move for it got caught on the conveyor for some reason.
1) The PWB can not go through smoothly since the conveyor is not connecting well to the machine in
the upper part of the line. Please re-adjust the connection.
2) The conveyor width is not matching the PWB width. Please re-adjust the conveyor width.
3) The PWB you are trying to convey does not match the specifications of your machine. The
following cases do not match your machine.
‧A PWB with thickness of 0.3mm or less. Or a PWB with thickness of 4mm or more.
‧A PWB with mass of 2kg or more.
2 If the PWB was NOT on the position where it is detected by IN sensor when the error
occurred.
If the IN sensor does not get OFF when a PWB is properly being conveyed, there is a possibility that
the sensor is detecting something else. Please select [Manual Control] from the menu bar, and then
select [Control(C)] [Conveyor(C)] [Independent Control of Conveyor(I)] to see the status of IN sensor
in the 'Status' frame.
1) If there is anything that IN sensor reacts to underneath the IN sensor, please remove it from under
the sensor or change the position of the sensor.
2) If the treatment1 does not work, please adjust the sensitivity of the sensor, using the volume
control knob attached to the sensor.
3) If the treatment2 does not work, there is a possibility that the IN sensor is broken. It could be that
the wiring came out of the connector part, that a contact pin of the connector part is broken, that
wiring got cut off, or that sensor itself is broken. Please examine the wiring and the connector. If any
of them are broken, you need to replace them with new ones.
  4) If the treatment3 does not work, a PCB is broken or the wiring between the PCBs is bad.
E650222 PWB Conveying Error : PWB conveying error of Input buffer. The process is forcibly terminated.
Please remove on the conveying route
传送基板错误 :|入口传感器和等待传感器同时被检测时错误。 |请卸下基板。
[Cause]
The belt of INPUT buffer got started to drive and a PWB was taken in to the INPUT buffer but the IN
sensor did not get OFF even if the WAIT sensor detected the PWB.
The PWB is taken in to the INPUT buffer and, if the WAIT sensor detects the PWB, the PWB
conveying stops and the PWB gets in a waiting mode. At this point, the IN sensor should not detect
anything.
[Treatment]
1 The PWB had been detected by WAIT and IN sensors when the error occurred.
1) The installation positions of IN and WAIT sensors are not correct. Please adjust the positions so
that the sensors do not detect anything at the same time.
2) The PWB you are trying to convey does not match the specifications of your machine. A machine
with M size specification can not deal with PWB that is over 330mm, a machine with L size
specification can not deal with PWB that is over 410mm, and a machine with E size specification can
not deal with PWB that is over 510mm
2 The PWB was staying on the position where IN sensor detected the PWB when the error
occurred (the error occurred before the PWB got to the WAIT sensor).
There is a possibility that the WAIT sensor detected something while the PWB was conveyed to the
Input buffer. Please select [Manual Control] from the menu bar, and then select [Control(C)]
[Conveyor(C)] [Independent Control of Conveyor(I)] to see the status of WAIT sensor in the 'Status'
frame.
1) If the light transmitter(LED) and light receiver(PT) of the wait sensor are not on the right positions,
please adjust them to make a correct alignment between them.
2) If the sensitivity of the WAIT sensor is not fine, please re-adjust it (The sensitivity of the sensor is
auto. tuning type. Please follow the maintenance manual to adjust it).
3) If there is anything between the light transmitter(LED) and light receiver(PT) of the WAIT sensor,
that interrupts the WAIT sensor such as wiring, please remove it or make it not to interrupt the sensor.
3 The PWB was staying on the position where WAIT sensor detected the PWB when the error
occurred (the PWB got to the right waiting position then the error occurred).
There is a possibility that the IN sensor detected something if the IN sensor does not get OFF while a
PWB is being conveyed properly. Please select [Manual Control] from the menu bar, and then select
[Control(C)] [Conveyor(C)] [Independent Control of Conveyor(I)] to see the status of IN sensor in the
'Status' frame.
1) If there is anything that IN sensor reacts to underneath the IN sensor, please remove it from under
the sensor or change the position of the sensor.
2)If the treatment1 does not work, please adjust the sensitivity of the sensor, using the volume control
knob attached to the sensor.
3) If the treatment2 does not work, there is a possibility that the IN sensor is broken. It could be that
the wiring came off the connector part, that a contact pin of the connector part is broken, that wiring
got cut off, or that sensor itself is broken. Please examine the wiring and the connector. If any of them
are broken, you need to replace them with new ones.
  4) If the treatment3 does not work, a PCB is broken or the wiring between the PCBs is bad.
E650223 PWB Conveying Error: PWB conveying error of Input buffer. The process is forcibly terminated.
Please remove on the conveying route
传送基板错误 :|入口缓冲区搬入基板出错,被强行停止。 |请取下基板。
[Cause]
IN sensor detected the next PWB while a PWB is waiting at the Input buffer. The IN sensor is not
supposed to be ON since a PWB request signal was not sent to a machine in the upper part of the line.
Usually, the error occurs when a machine in the upper part of the line outlets a PWB but the PWB
overruns, and the IN sensor detects the PWB.
[Treatment]
1 When a machine in the upper part of the line had outlet a PWB and the IN sensor had detected