JUKI贴片机错误代码集合.pdf - 第392页
“ VCS 识别校准块 D 时发生错误。 | 代码 : %ld|( 选择 [ 确定 ] ,把校准 块 D 归还到校准块上 ) ” E901202 “ Error has occurred duri ng acknowledgment of mark.|Code: %ld ” “ 识别标记时发生错误。 | 代码 : %ld ” E901203 “ Error has occurred when measuri ng center-to-c…
E901051 “Nozzle is set on %s.|Remove the nozzle.|Nozzle moves to jig installing position by selecting 'OK'.”
“%s上有吸嘴。|请取下吸嘴。|选择[确定],吸嘴向装配模具位置移动。”
E901052 “Nozzle is not set on %s.|Set nozzle in position.|Move nozzle to jig installing position by selecting
'OK'.| Select 'CANCEL' to ignore.”
“%s没有吸嘴。|请安装吸嘴。|选择[确定],吸嘴向装配模具位置移动。| 选择[取消],继续。”
E901053 “Component of jig has not been picked up.|Check that jig is placed on %s.”
“不能吸着模具组件。|请检查模具是否在%s上。”
E901061 “Center-to-center distance of marks cannot be measured.”
“不能测量标记中心间距。”
E901062 “Could not learn the height.|Please check the vacuum value.”
“不能取得高度。|请确认一下真空压。”
E901063 “Rotation center of nozzle is not input.|Setting laser offset”
“不存在吸嘴旋转中心。|请设定激光偏差。”
E901064 “1'st mark of CAL block cannot be detected.”
“不能查出校准块第一标记。”
E901071 “Sensor has not been set to OFF state.”
“没有关闭传感器。”
E901081 “Data has not been obtained.”
“不能取得数据。”
E901101 “Error has occurred when detecting height of measuring plane of laser.|Code: %ld”
“激光测量高度时发生错误。|代码: %ld”
E901102 “Error has occurred when setting laser parameters.|Code: %ld”
“设置激光参数时发生错误。|代码: %ld”
E901103 “Error has occurred during laser measurement(ONCE).|Code: %ld”
“激光测量(ONCE)时发生错误。|代码: %ld”
E901104 “Error has occurred during laser measurement(SWEEP).|Code: %ld”
“激光测量(SWEEP)时发生错误。|代码: %ld”
E901105 “Error has occurred during the nozzle(component) presence check.|Code: %ld”
“检测吸嘴(组件)存在性时发生错误。|代码: %ld”
E901201 “Error has occurred during acknowledgment of CAL piece D by VCS.|Code: %ld|(Return piece D to
CAL block by selecting 'OK'.)”
“VCS识别校准块D时发生错误。|代码: %ld|(选择[确定],把校准块D归还到校准块上)”
E901202 “Error has occurred during acknowledgment of mark.|Code: %ld”
“识别标记时发生错误。|代码: %ld”
E901203 “Error has occurred when measuring center-to-center distance of marks.|Code: %ld”
“测量标记中心间距时发生错误。|代码: %ld”
E901204 “Error has occurred during scaling setting.|Code: %ld”
“设置缩放比例时发生错误。|代码: %ld”
E901301 “Error has occurred on axis.|Code: %ld”
“轴发生错误。|代码: %ld”
E901302 “Error has occurred on axis of XY.|Code:%ld”
“XY轴发生错误。|代码:%ld”
E901303 “Error has occurred on axis of Z. (%s)|Code: %ld”
“Z轴发生错误。(%s)|代码: %ld”
E901304 “Error has occurred on axis of Theta. (%s)|Code: %ld”
“θ轴发生错误。(%s)|代码: %ld”
E901305 “The initialization error of transportation occurred. | Return to home is interrupted. Error code:%ld”
“搬运的初始化发生错误。|停止返回原点。错误代码:%ld”
E901306 “The PWB was detected in the transportation road.”
“传送轨道上有基板。”
W901401 “1.Vacuum generating power of ejector is beyond regular level.|Ejectors need to be changed.|2.Air is
leaking from the air pipe path |Air paths need to be inspected.”
“1.真空发生器的真空吸引力为规格之外。|需要更换排出器。|2.发生空气管道漏气。|需要
检查空气管道。”
W901402 “1.Vacuum generating power of ejector is low.|Ejectors need to be changed.|2.Air is leaking from
the air pipe path |Air paths need to be inspected.”
“1.真空发生器的真空吸引力偏低。|需要更换排出器。|2.发生空气管道漏气。|需要检查空
气管道。”
W901403 “Stuff in the air filter on the nozzle axis side.|Air filters need to be changed.”
“吸嘴轴侧的空气过滤器被塞满。|需要更换空气过滤器。”
W901404 “Latency of movement occurred due to the VAC electromagnetic valve trouble.|VAC
electromagnetic valves need to be changed.”
“因VAC电磁阀故障,发生动作迟钝现象。|需要更换VAC电磁阀。”
W901405 “Stuff in the air filter on the nozzle axis side.|Air filters need to be changed.”
“吸嘴轴侧的空气过滤器被塞满。|需要更换空气过滤器。”
W901406 “Latency of movement occurred due to the VAC electromagnetic valve trouble.|VAC
electromagnetic valves need to be changed.”
“因VAC电磁阀故障,发生动作迟钝现象。|需要更换VAC电磁阀。”
W901407 “Stuff in the air filter on the nozzle axis side.|Air filters need to be changed.”
“吸嘴轴侧的空气过滤器被塞满。|需要更换空气过滤器。”
W901408 “Stuff in the nozzle axis part of ejector.|Ejectors need to be changed.”
“真空发生器的吸嘴轴部被塞满。|需要更换发生器。”
W901409 “Latency of movement occurred due to the Blow electromagnetic valve trouble.|Blow
electromagnetic valves need to be changed.”
“因吹气电磁阀的故障,发生动作迟钝现象。|需要更换吹气电磁阀。”
E901501 “Error has occurred during acknowledgment of jig component by L3.|Status:%02x Error
code:%02x”
“发生L3识别故障。|状态:%02x 出错代码:%02x “
E901502 “Error has occurred during acknowledgment of jig component by L3.”
“发生L3识别故障。”
E901601 “The combination starting from ATC No. %s exceeded the allowable range.”
“ATC %s号开始同时交换吸嘴时,偏差超过允许范围。”
E901701 “The starting point position of LSC is outside the range. | The position of a starting point sensor
needs to be readjusted.”
“LSC的原点位置超过允许范围。|有必要调整原点传感器的位置。”
Q902001 “Reset I/O ?”
“是否设置I/O安全方向?”
Q902002 “Exit Ms parameters.|Save changes ?”
“退出MS参数设置。|是否保存设置?”
Q902011 “Return to home has not yet been completed.|Return to home ?”
“尚未运行返回原点。|是否进行返回原点?”
Q902012 “%s descends. Is there feeder etc. below the head ?”
“%s下降。Head底下是否有送料器等?”