JUKI贴片机错误代码集合.pdf - 第410页

W2903 “ Optimization processing is being abort ed. “ " 优化过程失败。 " E2907 Pick data is not complete. [Cause] The function Opt3Simu lParralelC reate returned error number 700. [Deal] Consult the manufacturer. E2911…

100%1 / 464
W2513 It cannot be placed in front of a dispenser.
"在分配前不能设置。"
W2514 It cannot be replaced with a dispenser.
"不能用分配者代替。"
W2515 It cannot be replaced with mounter.
"不能用贴片代替。"
W2516 Station cannot be changed because it is already installed in the line.
"位置不能被改变因为已经安装在线"
W2517 MTC will cause a conflict with permanent feeders. clear the area fron R-55 to R-63, then let MTC
use area.
"MTC 将导致和永久进料器的冲突,清除从 R55 R63 区域,让 MTC 使用区域。"
W2508 "Type of device is changed. Is this OK?"
"传送选项(长,宽)设置已被修改,初始化基板尺寸和基准坐标。"
W2520 Data of different style packaging cannot be copied.
"不同类型包装的数据不能复制。 "
E2900 emory is not enough in optimization.
"未受保护的优化区域处理正在进行"
[Cause]
Indicates insufficient free memory space.
[Deal]
Exit from other applications and retry the process.
E2901 Not found optimization message.
"挑选数据不完全。"
[Cause]
A failure was found in the data.
[Deal]
Complete the pick data.
E2902 System error.
"出现系统错误。"
[Cause]
Initializing DLL was failed.
[Deal]
Loading the files required by HLC was failed. Reinstall the system.
W2903 Optimization processing is being aborted.
"优化过程失败。"
E2907 Pick data is not complete.
[Cause]
The function Opt3SimulParralelCreate returned error number 700.
[Deal]
Consult the manufacturer.
E2911 Data is incorrect ,so stop allocation pick data of MTC.
"不正常数据探测; MTC 位置分配失败。"
[Cause]
A failure was found in the MTC data.
[Deal]
Correct the part data and pick data (MTC), and retry the process.
E2912 Data is incorrect so stop calculation for placement number.
"不正常数据已经导致计算贴片数量失败。"
[Cause]
A failure was found in the program data.
[Deal]
Rebuild the program data.
E2913 Data is incorrect ,so stop calculation for placement peak point.
"不正常数据已经导致贴片最高点计算失败。"
[Cause]
A failure was found in the program data.
[Deal]
Correct the mounting data, and retry the process.
E2914 Data is incorrect, so stop allocation for number of picking.
"不正常数据已经导致依照选取顺序分配失败。"
[Cause]
A failure was found in the program data.
[Deal]
Correct the pick data, and retry the process.
E2915 Sorting for placement layer and nozzle number is abnormal end.
"贴片层同一吸嘴号处理不正常。"
[Cause]
A failure was found in the program data.
[Deal]
Check the data (layer and nozzle information).
E2916 Data is incorrect ,so making for pairing placement data.
"不正常数据导致关系预备处理失败"
[Cause]
A failure was found in the program data.
[Deal]
Correct the data.
E2917 Memory is not enough at optimization feeder priority.
"在保护优先区域的进料器顺序处理过程中出现错误。"
[Cause]
Indicates insufficient free memory space.
[Deal]
Exit from other applications, and retry the process.
E2918 Data is incorrect , so stop processing for circuit repeat.
"不正常数据已经导致电路重复决定失败。"
[Cause]
A failure was found in the program data.
[Deal]
Correct the data.
E2931 Process for make feeder pair of parallel pick is abnormal end.
"同时选取进料器排版预先处理不正常终止"
[Cause]
The data is unavailable for optimization.
[Deal]
Consult the manufacturer.
E2932 Allocation for feeder pair of parallel pick is abnormal end.
"同时选取进料器排版处理不正常终止。"
[Cause]
The data is unavailable for optimization.
[Deal]
Consult the manufacturer.
E2933 Sorting for parallel pick feeder allocate is abnormal end.
"处理资料排架的同时选取进料器排版不正常终止。"
[Cause]