JUKI贴片机错误代码集合.pdf - 第272页
E630075 “ The window frame does not fit in the screen ” “ ViLib 错误 :| 窗口框超出画面 ” [Cause] The component outer shape window frame does not fit in the scre en if it is rotat ed to the tracing posture. [Treatment] The compone…
Failed in IPC reception from the vision device driver.
The vision device driver is HOLT.
[Treatment]
Please re-boot your machine.
E630052 “ViLib Entry: Error Execute Undefined Command”
“ViLib 错误:|发现未定义命令代码”
[Cause]
You tried to execute an undefined vision command.
Some program versions are clashing with each other.
[Treatment]
Please re-install or version up the application.
Please re-boot your machine.
E630053 “ViLib Thread: Undefined ViOS event is requested”
“ViLib 错误:|发现未定义 OS 事件要求”
[Cause]
You tried to issue an undefined vision event request.
Some program versions are clashing with each other.
[Treatment]
Please re-install or version up the application.
Please re-boot your machine.
E630054 “ViLibError:| Command handshake error (skipped ACK).”
“ViLib 错误:|命令同步交换错误(Skipped ACK)”
E630073 “Vision Data: Ball patter has not been set yet”
“ViLib 错误:|没有设置球图案”
[Cause]
There is no ball patter data in the vision data.
[Treatment]
Please examine the production program.
Please re-load the production program.
E630074 “Camera scale has not been set yet”
“ViLib 错误:|没有设置摄像机缩放比例”
[Cause]
There are some items that have not been set yet in the Camera scaling in MS Parameter.
[Treatment]
Please examine the Camera scaling in MS Parameter.
E630075 “The window frame does not fit in the screen”
“ViLib 错误:|窗口框超出画面”
[Cause]
The component outer shape window frame does not fit in the screen if it is rotated to the tracing
posture.
[Treatment]
The component is too large to trace.
E630076 “ViLibError:| VCS program checksum error”
“ViLib 错误:|图像(VCS)程序的 Check-Sum 错误”
E630077 “ViLibError:| VCS program flash write error”
“ViLib 错误:|图像(VCS)程序的闪存卡写入错误”
E630078 “ViLibError:| VME bus power is cut off.”
“ViLib 错误:|VMEBus 电源被关闭”
E630080 Vision system error:| Vision system error: ACK Response Base (Vision command result error).”
“图像处理装置错误:|图像处理装置错误:ACK 应答 Base(图像命令的结果错误)”
E630081 “There is not valid mark within the detecting window”
“图像处理装置错误:|在窗口中没有发现标记”
[Cause]
The light is not ON.
There is no mark.
[Treatment]
Please examine if the light gets on properly.
Please change the coordinates to where a mark exists or move the mark detecting frame.
E630100 “Vision System: The parameter value is illegal”
“图像处理装置错误:|参数值错误”
[Cause]
You tried to send an illegal data to VCS.
[Treatment]
Please examine the parameter.
E630101 “Vision System: parameter count is wrong”
“图像处理装置错误:|参数个数错误”
[Cause]
The format of the command interface between the VCS and your machine is not correct.
Some program versions are clashing with each other.
[Treatment]
Please re-install or version up the application.
Please re-boot your machine.
E630102 “Vision System: You tried to register an undefined component or mark”
“图像处理装置错误:|发现未定义的组件或标记”
[Cause]
The format of the command interface between the VCS and your machine is not correct.
Some program versions are clashing with each other.
[Treatment]
Please re-install or version up the application.
Please re-boot your machine.
E630103 “Vision System: Component ID number is invalid”
“图像处理装置错误:|参数个数错误”
[Cause]
An invalid component ID number is sent.
[Treatment]
Please examine the vision data in the production program.
Please re-load the production program.
E630104 “Vision System: Undefined command was issued”
“图像处理装置错误:|未定义命令”
[Cause]
The format of the command interface between the VCS and your machine is not correct.
Some program versions are clashing with each other.
[Treatment]
Please re-install or version up the application.
Please re-boot your machine.
E630105 “Vision System: Recognition conditions are not enough”
“图像处理装置错误:|识别条件设定不足”
[Cause]
The vision data in the production program is broken.
The format of the command interface between the VCS and your machine is not correct.
Some program versions are clashing with each other.
[Treatment]
Please examine the vision data in the production program.
Please re-load the production program.
Please re-install or version up the application.
Please re-boot your machine.