E606013 “ Axi s Driver:| XH-axis error.|Servo power is OFF .” “ XH 轴错误 : | 司服电源被关闭。 ” E606014 “ Axis Driver:| XH-axis error.|Driver alarm .” “ XH 轴错误 : | 发生驱动警报。 ” E606015 “ Axis Driver:| XH-axis error.|Amp disabled .” “…

100%1 / 464
E605331 Axis Driver:| AWC status error.”
自动调整基板宽度发生状态错误。
E605531 Axis Driver:| Center motor status error.”
中心马达发生状态错误。
E605631 Axis Driver:| Right Center motor status error.”
右中心马达发生状态错误。
E605132 Axis Driver:| Support table failed motion start.”
支撑台启动失败。
E605232 Axis Driver:| Right Support table failed motion start.”
右支撑台启动失败。
E605332 Axis Driver:| AWC failed motion start.”
自动调整基板宽度启动失败。
E605532 Axis Driver:| Center motor failed motion start.”
中心马达启动失败。
E605632 Axis Driver:| Right Center motor failed motion start.”
右中心马达启动失败。
E605133 Axis Driver:| Support table failed motion stop.”
支撑台停止失败。
E605233 Axis Driver:| Right Support table failed motion stop.”
右支撑台停止失败。
E605333 Axis Driver:| AWC failed motion stop.”
自动调整基板宽度停止失败。
E605533 Axis Driver:| Center motor failed motion stop.”
中心马达停止失败。
E605633 Axis Driver:| Right Center motor failed motion stop.”
右中心马达停止失败。
E606010 Axis Driver:| XH-axis parameter error.”
XH 轴错误: |参数错误。
E606012 Axis Driver:| XH-axis failed originating.”
XH 轴错误: |返回原点失败
E606013 Axis Driver:| XH-axis error.|Servo power is OFF.”
XH 轴错误: |司服电源被关闭。
E606014 Axis Driver:| XH-axis error.|Driver alarm.”
XH 轴错误: |发生驱动警报。
E606015 Axis Driver:| XH-axis error.|Amp disabled.”
XH 轴错误: |Amp 失效。
E606016 Axis Driver:| XH-axis error.|Position of Z-axis is low.”
XH 轴错误: | Z 轴下降而不能正常运行。
E606020 Axis Driver:| XH-axis gain setting failed.”
XH 轴错误: |设置增值参数失败。
E606030 Axis Driver:| XMP error occurred on XH-axis.”
XH 轴错误: |XMP 错误。
E606031 Axis Driver:| XH-axis status error.”
XH 轴错误: |状态错误。
E606032 Axis Driver:| XH-axis failed motion start.”
XH 轴错误: |启动失败。
E606033 Axis Driver:| XH-axis failed motion stop.”
XH 轴错误: |停止失败。
E610001 An error occurred when opening the ATC slide plate
打开 ATC 滑板出错。
[Cause]
An error occurred when trying to open the ATC slide plate. The error occurred in the Data
communication in the machine.
[Treatment]
‧Please turn off the power supply of your machine and reboot it.
‧If the error occurred after the installation or the version up of the software, you need to re-install
the software.
‧If the treatments above do not work, there is a possibility that MPX board(s) in the machine is
broken. You need to replace it(them) with new ones.
E610002 An error occurred when shutting the ATC slide plate
关闭 ATC 滑板出错。
[Cause]
An error occurred when trying to open the ATC slide plate. The error occurred in the Data
communication in the machine.
[Treatment]
‧Please turn off the power supply of your machine and reboot it.
‧If the error occurred after the installation or the version up of the software, you need to re-install
the software.
‧If the treatments above do not work, there is a possibility that MPX board(s) in the machine is
broken. You need to replace it(them) with new ones.
E610003 A time-out occurred when opening the ATC(L) slide plate
打开 ATC()滑板超时。
[Cause]
A process to open the left ATC slide plate was taken place but the plate did not open within a certain
amount of time. The follows could be the cause.
‧The air is not being supplied properly.
‧The slide plate that slides left and right to open and close the plate in the ATC unit does not work
properly.
‧The sensor which detects the position of the slide plate is not tuned well or broken.
[Treatment]
Please select [Manual Control] from the menu bar, and then select [Control(C )] [Other(O)] [ATC
Control(A)]. Set 'Control Unit' to 'left ATC', and select 'Slide plate Control(A)' from the 'Control Item'
frame' to open/close the slide plate. Please perform one of the treatments below according to the result
you get.
1. Slide plate works properly.
1.1 The 'Slide plate ON sensor' in the 'Status' displaying frame gets ON/OFF. The speed
controller of the Slide plate driving cylinder might be wrung too much toward its minimum limit.
Please loosen the controller.
1.2 The 'Slide plate ON sensor' in the 'Status' displaying frame does not get ON/OFF.
‧There is a possibility that the Slide plate ON sensor was adjusted to out of the Cylinder's movable
range. Please re-adjust the sensor to where it gets ON/OFF.
‧If the treatment1 does not work, there is a possibility that the slide plate ON sensor is broken. It
could be that the wiring came off the connector part, that a contact pin in the connector part is broken,
that the wiring got cut off, or that the sensor itself is broken. Please examine the wiring and connector.
If any of them are broken, you need to replace them with new ones.
‧If the treatment2 does not work, a PCB is broken or the wiring between the PCBs is bad.
2. Slide plate does not work.
‧There is a possibility that a nozzle is not installed in the ATC correctly and that prevent the slide
plate from sliding properly. Please see if nozzles are correctly installed in the ATC.
‧There is a possibility that a component or implement got caught in the sliding part of the slide plate
and that prevents the slide plate from sliding properly. Please see if there is anything on the slide