JUKI贴片机错误代码集合.pdf - 第128页

I508501 “ The position where each statio n is restarted is an installing p osition not install ed at a set statio n. |The restart production cannot be done. Please put the data again or clear the restart data .” “ 各站台的重新…

100%1 / 464
[Cause]
This message appears if the MTS door is open when starting a production.
[Treatment]
Please close the MTS door and press OK button. Pressing Cancel button will have you back to the
status that is before pressing START key.
E508200 Remove the component from %s
请取下%s 上的组件。
[Cause]
This message appears when starting a production after a request of taking a protective component off
is issued and the head is moved to the component disposal position.
[Treatment]
Please take the component off the head and press OK button.
E508300 The cause of the pause is not out of component. Measurement cannot be performed
不是因无组件而暂停,|不能执行测量
[Cause]
This message appears when a measurement functionality gets called by pressing F5 key while pausing
and the components are not running out.
[Treatment]
Please press OK button.
I508310 The cause of the pause is not out of component.|Inspection can not be performed.”
不是因无组件而暂停,|不能执行检查
I508320 The cause of the pause is not out of component.|Inspection can not be performed.”
不是因无组件而暂停,|不能执行检查
I508400 There is no component to be measured its height.”
测量组件高度的对象组件不存在。
I508410 There is no component which execute the verification inspection.”
数值检查所需的对象组件不存在。
I508420 There is no component which execute the SOT direction inspection.”
SOT 方向检查的对象组件不存在。
I508500 The position where a %s is restarted is the place data only in a %s. |The restart production cannot be
done. |Please put the data again or clear the restart data.”
%s 的重新开始位置是只对应%s 的贴片数据。|不能进行重新生产|请重新输入数据,或
删除重新开始数据。
I508501 The position where each station is restarted is an installing position not installed at a set station. |The
restart production cannot be done. Please put the data again or clear the restart data.”
各站台的重新开始位置,在设置站台中,不进行贴片的位置。不能进行重新生产。|请重
新输入数据,或删除重新开始数据。
I508600 Because the production program is edited, the thing to do Resume the product cannot be done though
Resume the product file exists. |Resume the product file is deleted.”
虽然存在继续生产文件,但是正在编辑生产程序,不能进行继续生产。|删除文件。
I508700 It is a production program where all the installing points cannot be installed.|Down-loaded the
production programs are produced in the idling mode.”
这个生产程序不能贴片全部的贴片点,|被下载的生产程序以通过方式进行生产。
I508710 Remove the nozzle from %s.”
%s 取出吸嘴。
Q509000 %s is re-set.|Would you like to continue the process?
重新设置当前显示的设备驱动情报|是否继续?
Q509001 The data with its button currently checked is re-set.|Would you like to continue the process?
重新设置当前被选的复选框内容,|否继续?
Q509002 All the Warning levels of Operation Information on each nozzle are re-set.|Would you like to
continue the process?
重新设置各吸嘴驱动情况的警告级别,|是否继续?
I509003 Button No Check
没有选择复选框。
Q509100 The selcted area of data is re-set.|Would you like to continue the process?
重新设置被选范围内容,|是否继续?
Q509101 All the displayed operation Information on each nozzle are re-set.|(Warning level and Error level
are not included).|Would you like to continue the process?
重新设置当前显示的各吸嘴驱动情|(不包括警告级别和错误级别)|是否继续?
Q509102 All the displayed operation Information on each head are re-set.|(Warning level and Error level are
not included).|Would you like to continue the process?
重新设置当前显示的各吸嘴驱动情|(不包括警告级别和错误级别)|是否继续?
I509200 Warning level is over the error level.|ATC : The warning level of %s can not be set.”
警告级别高于错误级别。|ATC : 不能设置%s 的警告级别。
I509201 The error level is less than the warning level.|ATC : The error level of %s can not be set.”
错误级别低于警告级别。|ATC : 不能设置%s 的错误级别。
I509210 error level is over the Warning level.|The warning level of %s can not be set.”
警告级别高于错误级别。|不能设置%s 的警告级别。
I509211 The warning level is less than the error level.|The error level of %s can not be set.”
错误级别低于警告级别。|不能设置%s 的错误级别。
Q509300 Number of picked components is over the error level.|Number of picked components  %d error
level  %d|Would you like to set the data?
ATC 交换次数超过错误级别。|ATC 交换次数:%d 错误级别:%d|是否设置资料?
Q509301 Number of placed components is over the Number of picked components.|Number of placed
components  %d Number of picked components  %d|Would you like to set the data?
总贴片数超过总吸取数。|总贴片数:%d 总吸取数:%d|是否设置资料?
Q509302 Number of placed components is over the Number of picked components.|Number of placed
components  %d Number of picked components  %d|Would you like to set the data?
交换吸嘴次数超过总吸取数。|交换吸嘴次数:%d 总吸取数:%d|是否设置资料?
E510001 The error occurred by the XY axis
XY 轴发生错误。
[Cause]
Something was wrong with XY axes movement.
[Treatment]
Please perform the Home returning.
E510002 The error occurred by the Z axis
Z 轴发生错误。
[Cause]
Something was wrong with XY axes movement.
[Treatment]
Please perform the Home returning.
E510003 The error occurred by the Theta axis
θ轴发生错误。
[Cause]
Something was wrong with the Theta axis movement.
[Treatment]
Please perform the Home returning.
E510004 The error occurred by the axis