JUKI贴片机错误代码集合.pdf - 第267页

E620024 “ MTS suppl y key .” “ MTS 供给 组件按钮被按下。 ” E620025 “ MTS onl ine key .” “ MTS 连接 按钮被按下。 ” E620026 “ Safety.B Setup .” “ 保护机 板设置 ” E620027 “ POWEROFF STOP ” “ 关闭动力状态 ” Q620028 “ ServoFree .” “ 未使用 伺服 ” E620029 “ Asy…

100%1 / 464
DATA3 = 4 [EEPROM abnormalityEEPROM 异常)]
Please change drivers(CPU boards).
请更换驱动器(CPU )
DATA3 = 5 [heating(发热)]
Please change drivers. If the error occurs again after the axis moves for a while, please examine the
FAN motor that is under the driver. If nothing is wrong with it, please examine the torque.
请更换驱动器。如果运转一段时间后出现发热现象,请检查驱动器底部的风扇。如果都没
有问题,请检查扭转负荷。
DATA3 = 6 [Encoder abnormality (编码器异常)]
Please examine the wiring of the encoder cables. If anything is wrong with it, then please change
motors.
请检查编码器电缆。如果电缆没有问题,请更换马达。
DATA3 = 7 [CPU abnormality DATA3=7CPU 异常)]
Please change drivers(CPU boards).
请更换驱动器(CPU )
E620016 Stopped. Both heads approach too much.”
停止运转,因为左右 Head 过于接近。
E620017 Slow down.Both heads approach.”
低速运转,因为左右 Head 过于接近。
E620018 Air pressure sensor alarm.”
发现气压下降。
E620019 Feeder bank is down.”
送料器台架下降。
E620020 MTC emergency stop.”
MTC 被紧急停止。
E620021 MTC supply key.”
MTC 供给组件按钮被按下。
E620022 MTC online key.”
MTC 连接按钮被按下。
E620023 MTS emergency stop.”
MTS 被紧急停止。
E620024 MTS supply key.”
MTS 供给组件按钮被按下。
E620025 MTS online key.”
MTS 连接按钮被按下。
E620026 Safety.B Setup.”
保护机板设置
E620027 POWEROFF STOP
关闭动力状态
Q620028 ServoFree.”
未使用伺服
E620029 Asynchronous system failed in Initialization. and was stopped.”
初始化失败,退出异步管理。
E620030 Asynchronous system status error.”
异步处理发生错误。
E620031 Open HistData failed.”
打开过去数据失败。
E620032 Open MSP Data failed.”
打开 MS 参数失败。
E620033 Create IPC failed.”
建立 IPC 失败。
E620034 Create Mutex failed.”
建立互(Mutex)失败。
E620035 Create Thread failed.”
建立线程失败。
E620036 Create Event failed. The machine cannot be correctly driven.”
建立事件失败。机器不能正常运转。
E620037 Open Event failed. Asynchronous system was stopped.”
打开事件失败,退出异步管理。
E620038 The machine type is not specified.Please specify the machine type.”
不是指定的机器种类。
E620039 I/O LibEntry initialization failed.”
I/O LibEntry 初始化失败。
E620040 Safety LibEntry initialization failed.”
Safety LibEntry 初始化失败。
E620041 LibEntry initialization failed.”
LibEntry 初始化失败
E620042 Initialization timer failed.”
更新过去数据时间初始化失败。
E620043 Reading E-Stop Status failed.”
读取紧急停止状态失败。
E620044 Reading XY-Alarm Status failed.”
读取 XY 警报状态失败。
E620045 Reading ZT-Alarm Status failed.”
读取 Zθ警报状态失败。
E620046 Waiting for Asynchonous event failed.”
进入异步事件等待状态失败。
E620047 Getting Asynchronous information failed.”
取得异步情报失败。
E620048 Filtering asynchronous information failed.”
选择处理异步情报失败。
E620049 Asynchronous system i/o error. Cannot clear input flags.”
异步系 I/O 错误,不能删除输入标记。
E620050 Asynchronous system error. Cannot set information.”
异步系统内部处理错误,不能保存输入的情报。
E620051 Exit Worker thread .”
退出工作线程。
E620052 Open SETUP Data failed.”
打开配置数据失败。
E620053 FAN STOP.”