JUKI贴片机错误代码集合.pdf - 第379页

‧If the error occurs even after the re-boot, there is a possib il ity that the Safety board is broken. Please contact our technical serv ice dept. for information. E691003 “ Deleting cue of flush mem ory d oes not get us…

100%1 / 464
unit is broken. Please contact our technical service dept. for information.
E690030 Voltage can not be measured. | Please check if probe shuts down properly
不能测定电压。|请检查探针是否已关闭。
[Cause]
The tester overflowed data when measuring the diode polarity.
‧The object(component) of the measurement is not contacting the probe.
‧The contact between the object(component) of the measurement and the probe is not good.
‧The resistance of the object(component) of the measurement is exceeding the measurement range.
‧The Component Verification is broken.
[Treatment]
‧Please check and see if the object is contacting the probe well. If not, please adjust the position of
the object to contact the probe properly.
‧Please check the object.
If the error occurs when the contact is good, there is a possibility that the Component Verification
unit is broken. Please contact our technical service dept. for information.
E690031 The power supply of the tester cannot be turned on.”
不能打开测试器电源。
E690032 Since air is falling, control of a probe is stopped.”
因为大气压太低,所以停止探针的控制。
E691001 Input/Output buffer status of CCL-48M does not get ready
CCL-48MI/O缓冲区不能达到就绪状态。
[Cause]
The input/output buffer status of the backup table counter(CCL-48M) does not get ready.
‧Backup table counter is broken.
[Treatment]
‧Please turn off the power supply and re-boot your machine.
‧If the error occurs even after the re-boot, there is a possibility that the Safety board is broken.
Please contact our technical service dept. for information.
E691002 Writing-in buffer of flush memory does not get useable
不能使用闪存卡的写入缓冲区。
[Cause]
'Writing-in' buffer did not get useable when checking its status after a 'writing-in' command to flush
memory was issued.
‧Flush memory is broken.
[Treatment]
‧Please turn off the power supply and re-boot your machine.
‧If the error occurs even after the re-boot, there is a possibility that the Safety board is broken.
Please contact our technical service dept. for information.
E691003 Deleting cue of flush memory does not get useable
不能使用闪存卡的删除指令。
[Cause]
'Deleting' cue did not get useable when checking its status after a 'deleting' command to flush memory
was issued.
‧Flush memory is broken.
[Treatment]
‧Please turn off the power supply and re-boot your machine.
‧If the error occurs even after the re-boot, there is a possibility that the Safety board is broken.
Please contact our technical service dept. for information.
E691004 WSM(Write State Machine) of flush memory does not get ready
闪存卡的WSM(Write State Machine)不能达到就绪状态
[Cause]
'WSM' did not get ready when checking its status after a command to flush memory was issued.
‧Flush memory is broken.
[Treatment]
‧Please turn off the power supply and re-boot your machine.
‧If the error occurs even after the re-boot, there is a possibility that the Safety board is broken.
Please contact our technical service dept. for information.
E691005 Write-in voltage range error occurred in flush memory control
闪存卡控制中发生写入电压范围错误。
[Cause]
An error occurred while checking the 'Write-in' voltage status after a command to flush memory was
issued.
The process was aborted since the 'write-in' voltage is too low.
‧Flush memory is broken.
[Treatment]
‧Please turn off the power supply and re-boot your machine.
‧If the error occurs even after the re-boot, there is a possibility that the Safety board is broken.
Please contact our technical service dept. for information.
E691006 Write-in error occurred in flush memory control
闪存卡控制中发生设备保护错误。
[Cause]
An error occurred while checking the 'device protecting' status after a command to flush memory was
issued.
The process was aborted since the master lock bit, block lock bit, and RP# lock were detected.
‧Flush memory is broken.
[Treatment]
‧Please turn off the power supply and re-boot your machine.
‧If the error occurs even after the re-boot, there is a possibility that the Safety board is broken.
Please contact our technical service dept. for information.
E691007 Write-in error occurred in flush memory control
闪存卡控制中发生写入错误。
[Cause]
An error occurred while checking the 'Write-in' status after a command to flush memory was issued.
An error occurred while writing data in.
‧Flush memory is broken.
[Treatment]
‧Please turn off the power supply and re-boot your machine.
‧If the error occurs even after the re-boot, there is a possibility that the Safety board is broken.
Please contact our technical service dept. for information.
E691008 Command sequence error occurred in flush memory control
闪存卡控制中发生指令次序错误。
[Cause]
An error occurred while checking the status after a command to flush memory was issued.
A command sequence error occurred.
‧Flush memory is broken.
[Treatment]
‧Please turn off the power supply and re-boot your machine.
‧If the error occurs even after the re-boot, there is a possibility that the Safety board is broken.
Please contact our technical service dept. for information.
E691009 Lock Bit Set error occurred n flush memory control
闪存卡控制中发生Lock Bit Set错误。
[Cause]
An error occurred while checking the 'lock bit set' status after a command to flush memory was
issued.
An error occurred while setting the master/block lock bit.
‧Flush memory is broken.
[Treatment]
‧Please turn off the power supply and re-boot your machine.
‧If the error occurs even after the re-boot, there is a possibility that the Safety board is broken.