[Treatment] 1 The PWB was on the position where it is det ected by STOP s ensor on the center station on the Entrance side when the error occurred. The PWB can not move for it got caught on t he conveyor for some reason.…
following cases do not match your machine.
‧ A PWB with thickness of 0.3mm or less. Or a PWB with thickness of 4mm or more.
2 If the belt was moving for a while after the PWB touched the stopper when the error occurred.
The STOP sensor is not detecting the PWB. Please select [Manual Control] from the menu bar, and
then select [Control(C)] [Conveyor(C)] [Independent Control of Conveyor(I)] to see the status of
STOP sensor in the 'Status' frame.
1)The sensitivity of the STOP sensor may be too low. Please re-adjust the sensitivity of the sensor,
using the volume control knob attached to the sensor.
2) If the treatment1 does not work, there is a possibility that the STOP sensor is broken. It could be
that the wiring came out of the connector part, that a contact pin in the connector part is broken, that
wiring got cut off, or that sensor itself is broken. Please examine the wiring and the connector. If any
of them are broken, you need to replace them with the new ones.
3) If the treatment2 does not work, PCB is broken or the wiring between the PCBs is bad.
E650235 “PWB Conveying Error :| C.OUT sensor ON detection time out error.”
“传送基板错误 :|C.OUT传感器 ON超时。”
E650236 “PWB Conveying Error :| C.OUT sensor ON detection error at Center stopper ON.”
“传送基板错误 :|中心STOP ON时,发现C.OUT传感器ON错误。”
E650237 “PWB Conveying Error :| STOP sensor ON detection error at Center stopper ON.”
“传送基板错误 :|中心STOP ON时,发现STOP传感器ON错误。”
E650238 “PWB Conveying Error :| When the PWB Vacuume is controlled. | it is Vacuume Sensor ON
detection time out.”
“传送基板错误 :|基板吸取被控制时,真空传感器 ON超时。”
E650239 “PWB Conveying Error :| When the PWB Vacuume is controlled. | it is Vacuume Sensor OFF
detection time out.”
“传送基板错误 :|基板吸取被控制时,真空传感器 OFF超时。”
E650240 “PWB Conveying Error :| Setting the Vacuum Table use is defferent | from setting the machine
setup.”
“传送基板错误 :|真空台使用设置与机器设置不同。”
E650242 “PWB Conveying Error : PWB conveying error of the center station on the Entrance side. The
process is forcibly terminated. Please remove on the conveying route”
“传送基板错误 :|STOP1传感器OFF超时。”
[Cause]
This error occurs if the STOP sensor on the center station on the Entrance side got OFF then ON
again, but it does not get OFF even if a certain amount of time has passed since it got ON again when
conveying a PWB on the center station on the Entrance side to the center station on the Exit side.
[Treatment]
1 The PWB was on the position where it is detected by STOP sensor on the center station on the
Entrance side when the error occurred.
The PWB can not move for it got caught on the conveyor for some reason.
1) The conveyor width is not matching the PWB width. Please re-adjust the conveyor width.
2) The PWB you are trying to convey does not match the specifications of your machine. The
following cases do not match your machine.
‧A PWB with thickness of 0.3mm or less. Or a PWB with thickness of 4mm or more.
‧A PWB with mass of 2kg or more.
2 The PWB was NOT on the position where it is detected by STOP sensor on the center station
on the Entrance side when the error occurred.
If the STOP sensor does not get OFF when a PWB is properly being conveyed, there is a possibility
that the sensor is detecting something else. Please select [Manual Control] from the menu bar, and
then select [Control(C)] [Conveyor(C)] [Independent Control of Conveyor(I)] to see the status of
STOP sensor on the center station on the Entrance side in the 'Status' frame.
1) The sensitivity of STOP sensor may be too high. Please adjust it, using the volume control knob
attached to the sensor.
2) If the treatment1 does not work, there is a possibility that the STOP sensor is broken, It could be
that the wiring came off the connector part, that a contact pin in the connector part is broken, that
wiring got cut off, or that sensor itself is broken. Please examine the wiring and the connector. If any
of them are broken, you need to replace them with new ones.
3)If the treatment2 does not work, a PCB is broken or the wiring between the PCBs is bad.
E650243 “PWB Conveying Error : PWB conveying error of the center station on the Entrance side. The
process is forcibly terminated. Please remove on the conveying route”
“传送基板错误 :|C.OUT1传感器OFF超时。”
[Cause]
This error occurs if the C-OUT sensor on the center station on the Entrance side got OFF then ON
again, but it does not get OFF even if a certain amount of time has passed since it got ON again when
conveying a PWB on the center station on the Entrance side to the center station on the Exit side.
[Treatment]
1 The PWB was on the position where it is detected by C-OUT sensor on the center station on
the Entrance side when the error occurred.
The PWB can not move for it got caught on the conveyor for some reason.
1) The conveyor width is not matching the PWB width. Please re-adjust the conveyor width.
2) The PWB you are trying to convey does not match the specifications of your machine. The
following cases do not match your machine.
‧A PWB with thickness of 0.3mm or less. Or a PWB with thickness of 4mm or more.
‧A PWB with mass of 2kg or more.
2 The PWB was NOT on the position where it is detected by C-OUT sensor on the center station
on the Entrance side when the error occurred.
If the C-OUT sensor does not get OFF when a PWB is properly being conveyed, there is a possibility
that the sensor is detecting something else. Please select [Manual Control] from the menu bar, and
then select [Control(C)] [Conveyor(C)] [Independent Control of Conveyor(I)] to see the status of
STOP sensor on the center station on the Entrance side in the 'Status' frame.
1) The sensitivity of C-OUT sensor may be too high. Please adjust it, using the volume control knob
attached to the sensor.
2) If the treatment1 does not work, there is a possibility that the C-OUT sensor is broken, It could be
that the wiring came off the connector part, that a contact pin in the connector part is broken, that
wiring got cut off, or that sensor itself is broken. Please examine the wiring and the connector. If any
of them are broken, you need to replace them with new ones.
3) If the treatment2 does not work, a PCB is broken or the wiring between the PCBs is bad.
E650244 “PWB Conveying Error : PWB conveying time out error of the center station on the Entrance side.
The process is forcibly terminated. Please remove on the conveying route”
“传送基板错误 :|在入口侧中心缓冲区,基板移动超时。”
[Cause]
This error occurred because the STOP sensor on the center station on the Entrance side did not get
ON even though a certain amount of time has passed since the WAIT sensor on the Input buffer got
OFF when conveying a PWB on the Input buffer to the center station on the Entrance side. Usually,
this error occurs when a PWB can not go through the INPUT buffer for some reason.
[Treatment]
1 The PWB was on the position where it is NOT detected by WAIT sensor or STOP sensor on
the center station on the Entrance side when the error occurred.
The PWB can not move for it got caught on the conveyor for some reason.
1) The conveyor width is not matching the PWB width. Please re-adjust the conveyor width.
2) The PWB you are trying to convey does not match the specifications of your machine. The
following cases do not match your machine.
‧A PWB with thickness of 0.3mm or less. Or a PWB with thickness of 4mm or more.
‧A PWB with mass of 2kg or more.
2 If the belt was moving for a while after the PWB touched the stopper on the center station on
the Entrance side when the error occurred.
The STOP sensor on the center station on the Entrance side is not detecting the PWB. Please select
[Manual Control] from the menu bar, and then select [Control(C)] [Conveyor(C)] [Independent
Control of Conveyor(I)] to see the status of STOP sensor in the 'Status' frame.
1) The sensitivity of the STOP sensor may be too low. Please re-adjust the sensitivity of the sensor,
using the volume control knob attached to the sensor.
2) If the treatment1 does not work, there is a possibility that the STOP sensor is broken. It could be