[Cause] Failed to draw the MTS tray ou t si nce the MTS door was open. [Treatment] Please close the MTS door. E290000 “ The origin point return is non-completi on. | Please execute the teaching after the origin point ret…
[Treatment]
Please turn on the power supply of MTS.
E249008 “The door of MTS opens”
“MTS 门已打开”
[Cause]
Failed to draw the MTS tray out since the MTS door was open.
[Treatment]
Please close the MTS door.
E249009 ”MTS offline”
“MTS 处于脱机状态”
[Cause]
MTS is not online.
[Treatment]
Please make MTS online.
E249010 “Servo is in the free state. The bank mark recognition is aborted”
[Cause]
The axis could not move since the servo was not locked.
[Treatment]
Please lock the servo using S-FREE switch.
Q249051 “Feeder bank has descended. Do you want to lift the feeder bank up and continue the bank mark
recognition?”
“送料器台架被下降。| 是否升高台架后,继续识别台架标记?”
[Cause]
The feeder bank had been descended when you tried to perform the Bank mark recognition.
[Treatment]
“YES” button will continue the Bank mark recognition process.
“NO” button will completely abort the Bank mark recognition process.
I249070 “Set online for MTS”
“设置的 MTS 没有联线”
[Cause]
Failed to draw the MTS tray out since the MTS was not online.
[Treatment]
Please make MTS online.
I249071 “Please close the door of MTS”
“请关闭 MTS 门”
[Cause]
Failed to draw the MTS tray out since the MTS door was open.
[Treatment]
Please close the MTS door.
E290000 “The origin point return is non-completion. | Please execute the teaching after the origin point
returns”
“没有执行原点返回。|请执行原点返回后,进行示教。”
[Cause]
Home returning has not been complete yet.
[Treatment]
Please press ORIGIN button to perform the Home returning, then try the teaching again.
E290001 “The OCC device is set in unused by the setup. | The teaching in the OCC device cannot be done”
“在设置中,OCC 装置没有被选用。”
[Cause]
OCC device is set to “not use” in the Use unit in Setup.
[Treatment]
If OCC is available, please set it to “use” in the Use unit in Setup. If not, this procedure cannot be
executed.
E290002 “The bad mark reader device is set in unused by the setup. | The teaching in the bad mark reader
device cannot be done”
”在设置中,识别坏板标记装置没有被选用。”
[Cause]
The Bad mark reader device is set to “not use” in the Use unit in Setup.
[Treatment]
If the Bad mark reader device is available, please set it to “use” in the Use unit in Setup. If not, this
procedure cannot be executed.
E290003 “The HMS device is set in unused by the setup. | The teaching in the HMS device cannot be done”
“在设置中,HMS 装置没有被选用。”
[Cause]
The HMS device is set to “not use” in the Use unit in Setup.
[Treatment]
If the HMS device is available, please set it to “use” in the Use unit in Setup. If not, this procedure
cannot be executed.
E290004 “The pick up point in the right feeder bank cannot be the teaching with a left device. Please use a
right device”
“不能以左侧装置示教右侧送料器台架上的吸着坐标。请选用右侧装置。”
[Cause]
This error occurs when trying to teach a feeder pickup coordinate on the right feeder bank to the
machine by using a device on the left side.
[Treatment]
Please use a device on the right side when teaching a feeder pickup coordinate on the right feeder
bank to the machine.
E290005 “The pick up point in the left feeder bank cannot be the teaching with a right device. Please use a left
device”
“不能以右侧装置示教左侧送料器台架上的吸着坐标。请选用左侧装置。”
[Cause]
This error occurs when trying to teach a feeder pickup coordinate on the left feeder bank to the
machine by using a device on the right side.
[Treatment]
Please use a device on the left side when teaching a feeder pickup coordinate on the left feeder bank
to the machine.
E290006 “The memory access error occurred”
“访问内存出错。”
[Cause]
Failed to write the data in or to read the data from the shared memory.
[Treatment]
Please reboot the machine. If the error occurs even after rebooting, please contact our technical
service dept. for information.
E290007 “The Head device is set in unused by the setup”
“在设置中,Head 装置没有被选用。”
[Cause]
The specified head is set to “not use” in the Use unit in Setup.
[Treatment]
If the specified head is available, please set it to “use” in the Use unit in Setup. If not, this procedure
cannot be executed.
E290008 “HW error. Execution is aborted”
“因硬件出错,停止运行。”
[Cause]
A requested action to an axis or other hardware got an error. There may be a possibility of alarm
occurrence, servo free, Emergency STOP, etc.
[Treatment]
Please try Servo Free unlocking, Home returning, etc.