JUKI贴片机错误代码集合.pdf - 第109页
[Cause] An error occurred in DTS. [Treatment] This is a DTS internal error. Pl ease take a not e of the error n umber and contact our technical service dept. for information. E501201 “ DTS stat us got an error. The proce…
E501102 “MTS cannot move because of cover opening”
“MTS 不能移动,因为机盖被打开。”
[Cause]
MTS cover was open when starting a production.
[Treatment]
Please close the MTS cover and press OK button. Pressing Cancel button will have you back to the
status that is before pressing START key.
E501103 “The door of MTS opens”
“MTS 的门被打开。”
[Cause]
MTS door was open when starting a production.
[Treatment]
Please close the MTS door and press OK button. Pressing Cancel button will have you back to the
status that is before pressing START key.
E501104 “MTS is Door Open Condition.|Please Close Door”
“MTS 的门被打开,|请关闭门。”
E501105 “MTS is Cover Open Condition.|Please Close Cover”
“MTS 机盖被打开,|请关闭机盖。”
E501106 “MTS is Error Condition”
“MTS 发生错误。”
E501107 “MTS is Change Component Condition.|Please Release the Change Condition”
“MTS 处于组件交换状态,|请解除组件交换状态。”
E501108 “Component exists on the MTS Shuttle.|Please Remove Component from Shuttle”
“MTS 滑梭上存在组件,|请取下组件。”
E501109 “Because MTS is Change Component Condition, |home position return cannot be done.|Please
Release the Change Condition”
“因 MTS 处于组件交换状态,不能进行返回原点。|请解除组件交换状态。”
E501110 “There is no MTS Component in the production program.”
“生产程序内不存在 MTS 组件。”
E501111 “MTS failed to return to the ORIGIN.|Would you like to have MTS return to Home Position?”
“MTS 返回原点失败,|是否重新执行返回原点?”
E501200 “Communication error of DTS occurred”
“DTS 通讯出错。”
[Cause]
An error occurred in DTS.
[Treatment]
This is a DTS internal error. Please take a note of the error number and contact our technical service
dept. for information.
E501201 “DTS status got an error. The process can not be performed”
“DTS 发生错误,|不能执行处理。”
[Cause]
This error occurs if DTS is in an error status when starting a production.
[Treatment]
Please turn off the power supply of DTS and examine it.
E501202 “DTS' cover is open. Please close the cover”
“DTS 机盖被打开,|请关闭机盖。”
[Cause]
This error occurs if DTS cover is open when starting a production.
[Treatment]
Please close the DTS door and press OK button. Pressing Cancel button will have you back to the
status that is before pressing START key.
E501203 “DTS is not in the executable status. Would you like to have DTS return to Home position?”
“DTS 未完成返回原点,|进行返回原点。”
[Cause]
This error occurs if DTS Home returning has not been complete when starting a production.
[Treatment]
OK button : Performs DTS Home returning.
Cancel button : Will have you back to the status that is before pressing START key.
E501204 “DTS is not in the executable status. Would you like to have DTS return to Home Position?”
“DTS 处于不能执行状态,|是否执行返回原点?”
[Cause]
This error occurs if DTS is in the executable status when starting a production.
[Treatment]
OK button : Performs Home returning.
Cancel button : Will have you back to the status that is before pressing START key.
E501205 “DTS is in the supplying status. Please release DTS from the status”
“DTS 处于补充状态,|请解除补充状态。”
[Cause]
This error occurs if DTS is in the supplying status when starting a production.
[Treatment]
Please disable the supply status of DTS and press OK button. Pressing Cancel button will have you
back to the status that is before pressing START key.
E501300 “No tracing data”
“无跟踪数据。”
[Cause]
This error occurs if there is not data to trace on the specified station when executing tracing.
[Treatment]
Please press OK button to continue the process.
E501400 “[Vision] Memory access error”
“[图像]访问内存失败。”
[Cause]
There is not enough memory.
[Treatment]
Please re-start the application.
E501401 “[Vision] Failed to collect System condition data”
“[图像]收集系统条件失败。”
[Cause]
The system information is wrong.
[Treatment]
Please re-boot your machine.
E501402 “[Vision] Failed to collect Mark recognition condition data”
“[图像]标记数据不正确。”
[Cause]
The entered mark data is not correct.
[Treatment]
Please go to the Production Program Editor and check the mark data.
E501403 “[Vision] Failed to collect Component recognition condition data”
“[图像]第%d 号组件的图像(或其它)数据不正确|请检查组件图像数据。”
[Cause]
The entered vision data is not correct.
[Treatment]
Please go to the Production Program Editor and check the mark data.
E501404 “[Vision] Failed to transmit System condition data to the Vision board”
“[图像]传送系统条件数据到图像卡失败。”