JUKI贴片机错误代码集合.pdf - 第70页

“ XY 轴发生错误。 ” [Cause] An error occurred while XY axes were traveling. [Treatment] Please contact our technical serv ice dept. for information. E301057 “ An error on Z axis occurred ” “ Z 轴发生错误。 ” [Cause] An error occurre…

100%1 / 464
In 2030, Vacuum Calibration unit can be set only for R1 through R4.
[Treatment]
Please set to ATC of R1 through R4.
E301051 Vacuum Calibration can be et only for small-diameter nozzles. | (Settable range : 1 - %d)
对于该 ATC 不能设置真空校准。
[Cause]
The Vacuum Calibration unit can not be set other ATC than the ATC of small nozzles.
|The maximum settable ATC number
[Treatment]
Please set the unit for the ATC of small nozzles.
E301052 Any heads have not been specified
没有指定 Head
[Cause]
You did not specify a head to be measured.
[Treatment]
Please specify a head to measure.
E301053 The Changer table can not be installed on the rear side since MTC/MTS have been selected
MTC/MTS 已被选择,不能把送料器台车安装在后侧。
[Cause]
You can not use the changer table on the rear side when MTC or MTS is set to use.
[Treatment]
Please disable MTC or MTS when you use the changer table on the rear side.
E301054 MTC/MTS can not be connected to 2000 series machines at the same time
不能同时连接 MTC MTS
[Cause]
MTC and MTS can not be set at the same time.
[Treatment]
Please disable one of them.
E301055 An error on axes occurred
轴发生错误。
[Cause]
An error occurred while axes were traveling.
[Treatment]
Please contact our technical service dept. for information.
E301056 An error on XY axes occurred
XY 轴发生错误。
[Cause]
An error occurred while XY axes were traveling.
[Treatment]
Please contact our technical service dept. for information.
E301057 An error on Z axis occurred
Z 轴发生错误。
[Cause]
An error occurred while Z axis was traveling.
[Treatment]
Please contact our technical service dept. for information.
E301058 Specified 508 nozzle has not been assigned yet. Please execute nozzle assignment
没有安装指定的 508 吸嘴。|请安装吸嘴。
[Cause]
508 nozzle is necessary to auto-teach MTC shuttle pick position to the machine, but the 508 nozzle
has not been assigned yet..
[Treatment]
Please assign the 508 nozzle, then try auto-teaching.
E301059 It was impossible to learn the height. | Please check out the vacuum value
不能取得高度。|请检查一下真空值。
[Cause]
An abnormal matter happened while learning the height by vacuum.
[Treatment]
Please check and see if the vacuum pressure is correct.
E301060 DTS/MTS can not be connected to 2000 series machines at the same time
不能同时连接 DTS MTS
[Cause]
DTS and MTS can not be set at the same time.
[Treatment]
Please disable one of them.
E301061 Feeder float detector can not be set only out position
传送带浮动传感器不能只安装在外侧。
[Cause]
You can not use the outer feeder float detectors only.
[Treatment]
Please use the inner feeder float detectors only or use all the detectors at once.
E301062 There is no head that can move to specified position.”
不存在可以移到指定位置的吸嘴。
W301063 Selected MTC/MTS is not connected.”
已被选用的 MTC/MTS 处于脱机状态。
E301064 MTS is in the supply state.”
MTS 处于补充状态。
E301065 %s ||Specified nozzle data has not been registered.|Please register nozzle data.”
%s ||吸嘴信息没有注册。|请注册吸嘴信息。
E301066 The nozzle no. is invalid.”
无效的吸嘴号。
E301067 A drive can not be access.|Please check the FD
不能访问 A 驱动器。|请确认一下软盘。
E301068 Because the right head is disable, it can not be measured.”
因为 Head 处于不使用状态,所以不能进行测量。
E301069 Input value exceeds predetermined data range.”
输入数据超过范围。
E301070 It can not be set the small nozzle on a large ATC.”
大型 ATC 上不能安装小型吸嘴。
E301071 The SemiAuto Trash box is not at the abandonment position.|Please set the SemiAuto Trash box at
the abandonment position.”
半自动废弃盒不在废弃位置。|请把半自动废弃盒设置在废弃位置。
E301072 The production program has not read.”
不能读取生产程序。
E301073 An error occurred while BOC alignment.”
BOC 校准发生错误。
E301074 An error occurred while BOC Mark Correct.”
BOC 标记校正发生错误。
W301075 Because the nozzle data[ %s ] is initial data, it can not be delete.”
因为被选吸嘴的信息[ %s ]是初始数据,不能删除。
W301076 Input value exceeds the simultaneous BOC mark recognition limit.|Please check out the Y value.”
输入值超过了同时识别 BOC 标记的范围。|请检查一下 Y 坐标值。