JUKI贴片机错误代码集合.pdf - 第81页
[Cause] Z axis coordinate by HMS could not be learned since it was out of the measurement range (-40mm through +40mm) [Treatment] Pleas e check and see if the m easuring posi tion (XY coordinates ) of HMS is correct or n…
[Cause]
An error occurred during the measurement(SWEEP) by laser.
1): Error code
2): A communication error occurred.
3): An axis error occurred
Other : Please reference [Status list] in [Laser Control] in Manual Control.
[Treatment]
Please reference [Status list] in [Laser Control] in Manual Control.
E316104 “Error has occurred during the nozzle presence check | code:%ld”
“检查喷嘴是否存在时,发生错误。|代码: %ld”
[Cause]
An error occurred during the measurement(ONCE) by laser.
1): Error code.
2): A communication error.
[Treatment]
Please reference [Status list] in [Laser Control] in Manual Control.
E316105 “Error has occurred during the image data obtain. | code:%ld”
“获取图像数据发生错误。|代码: %ld”
[Cause]
An error occurred while getting the Image data by laser.
1): Error code
2): A communication error occurred.
Other : Please reference [Status list] in [Laser Control] in Manual Control.
[Treatment]
Please reference [Status list] in [Laser Control] in Manual Control.
E316106 “Error has occurred during the edge check data learning. | code:%ld”
“获取确定边界数据发生错误。|代码: %ld”
[Cause]
An error occurred while getting the Edge check by laser.
1): Error code.
2): A communication error occurred.
Other : Please reference [Status list] in [Laser Control] in Manual Control.
[Treatment]
Please reference [Status list] in [Laser Control] in Manual Control.
E316107 “Data has not been learned”
“不能获取数据。”
[Cause]
Z axis coordinate by HMS could not be learned since it was out of the measurement range (-40mm
through +40mm)
[Treatment]
Please check and see if the measuring position (XY coordinates) of HMS is correct or not.
E316301 “MTC power off”
“MTC 电源被关闭。”
[Cause]
The power supply of MTC is off.
[Treatment]
Please turn on the power supply of MTC, and make it online.
E316302 “MTC offline”
“MTC 处于脱机状态。”
[Cause]
MTC is not online
[Treatment]
Please make MTS online.
E316303 “MTC is in the supply state”
“MTC 处于补充状态。”
[Cause]
MTC can not be controlled since it is in the Supply (component change) state.
[Treatment]
Please make MTC a normal status.
E316401 “MTS power off”
“MTS 电源被关闭。”
[Cause]
Failed to draw the MTS tray out since the MTS was not ON.
[Treatment]
Please turn on the power supply of MTS.
E316402 “MTS offline”
“MTS 处于脱机状态。”
[Cause]
Failed to draw the MTS tray out since the MTS was not online.
[Treatment]
Please make MTS online.
E316403 “MTS cannot move because of cover opening”
“因主机盖被打开,MTS 不能运转。”
[Cause]
Failed to draw the MTS tray out since the cover of the machine was open.
[Treatment]
Please close the cover.
E316404 “The door of MTS opens”
“MTS 机箱门被打开。”
[Cause]
Failed to draw the MTS tray out since the MTS door was open.
[Treatment]
Please close the MTS door.
E316405 “There is no specified stacker with the tray steps number”
“指定阶层托盘存储箱不存在。”
[Cause]
Failed to draw the MTS tray out since there was no stacker which has the specified number of trays.
[Treatment]
Please set the stacker with specified number of trays.
E316406 “MTS is in the supply state.”
“MTS 处于补充状态。”
E316501 “Error has occurred on axis | code:%ld”
“轴移动发生错误。|代码: %ld”
[Cause]
An error occurred while an axis was traveling.
[Treatment]
E316502 “The initialization error of transportation occurred. Return to home is interrupted. Error code:%ld”
“搬运初始化失败。|中断原点返回。错误代码:%ld”
[Cause]
The initialization error of transportation occurred.
[Treatment]
E316503 “The PWB was detected in the transportation road”
“发现搬运轨道上存在基板。”
[Cause]
A PWB was detected on the conveyor.
[Treatment]