JUKI贴片机错误代码集合.pdf - 第431页
" 作为线数据不匹配 ( %d 警告 ) " [Explanation] Appears if executing the line consist ency check founds an error . E3831 Can not execute data mismatch check. " 不能执行数据匹配检查 ." [Cause] Memory space is not sufficien…
"头不能移动到选取点."
[Cause]
The pick-up position is not set within the area where a head can move.
[Deal]
Change the pick-up position to a new position where a head can move.
E3825 Station which can handle selected needle is not in the line.
"能处理选择针的位置不在线上."
[Cause]
Indicates that the needle specified in the adhesion data is not set for the applicator used on the line.
[Deal]
Look up the MSL setup for the needle setting of the applicator used on the line, or specify another
needle for the adhesion data.
E3826 The number of necessary resources in resource table has been exceeded.
"必须资源的数量在资源表中已经被超过."
[Cause]
Indicates that excessive number of resources are specified for the resource table.
[Deal]
Increase the number of the resources available for the resource table during the MSL setup.
E3827 Data mismatch as a line has completed normally.
"在数据一致性检查中未发现错误."
[Explanation]
The line consistency check has been completed successfully. Now, it is the time for optimizing. We
hope there occurs no error.
E3828 Error list file %s Do you want to see an error list?
"错误表文件 %s想要看错误表吗?"
[Explanation]
Appears when any error was found by the line consistency check. If "Yes" is pressed, the notepad
opens and the contents of the error is printed. If "No" is pressed, the prompt is erased.
E3829 Data mismatch as a line found ( %d errors )
"作为线数据不匹配( %d 错误)"
[Cause]
Appears if the line inconsistency check found an error.
[Deal]
Fix the error and restart the process.
W3830 Data mismatch as a line found ( %d warnings )
"作为线数据不匹配( %d 警告 )"
[Explanation]
Appears if executing the line consistency check founds an error.
E3831 Can not execute data mismatch check.
"不能执行数据匹配检查."
[Cause]
Memory space is not sufficient.
[Deal]
Quit other running applications, then restart it.
E3832 Can not execute NOTEPAD.
"不能激活记事本."
[Cause]
Memory space is not sufficient.
[Deal]
Quit other running applications, then restart it.
E3833 No station exists which can handle IC mark.
"没有位置存在能处理 IC 标记."
[Cause]
Indicates that there is none of 720, 730, 730plus, 740, 750,760 and 2000 series stations on the line,
but the mounting data uses the IC mark.
[Deal]
Add any of a 720, 730, 730plus 740, 750,760 and 2000 series station on the line during the MSL
setup.
E3834 IC mark data is assigned to the station which cannot handle it.
"IC 标记数据被分配在位置上,不能处理."
[Cause]
Appears if the specified station is none of 720, 730, 730plus, 740, 750,760 and 2000 series stations,
or is disabled in the unit status during the MSL setup.
[Deal]
Make sure that the specified station is the one available for the IC mark, or is not disabled in the unit
status during the MSL setup, and restart the process.
When checking the unit status of the MSL setup, check to see if the BOC camera is disabled for 720,
if OCC is disabled for 730, 730plus, 740, 750, and 760, and if OCC-L or OCC-R is disabled for 2010,
2020, 2030, and 2040.
E3835 Station which can handle MTC is not in the line.
" 能处理 MTC 的位置不在线上."
[Cause]
Indicates that none of 720, 730, 740, 750,760,2010,2020 and 2040 stations is set on the line, but the
part data specifies the tray (MTC) for the package style on the line.
[Deal]
Add any of a 720, 730, 740, 750,760,2010,2020 and 2040 station on the line during the MSL setup.
E3836 MTC is assigned to the station which cannot handle it.
"MTC 被分配给的位置不能处理."
[Cause]
Indicates that the specified station is none of 720, 730, 740, 750,760,2010,2020 and 2040 stations, or
it is disabled in the unit status of the MSL setup.
[Deal]
Make sure that the specified station is the one capable of using the MTC, or is not disabled in the
unit status during the MSL setup, and restart the process.
E3837 Standard VCS is not available on this station.
[Cause]
Indicates that the specified station is none 720, 740,760,2020 and 2040 stations, or it is disabled in the
unit status of the MSL setup.
[Deal]
Make sure that the specified station is the one capable of using the MTC, or is not disabled in the
unit status during the standard VCS setup, and restart the process.
E3838 No station in the line can use standard VCS.
[Cause]
Indicates that none of a 720, 740,760,2020 and 2040 stations is set on the line, despite the vision part
is enabled.
[Deal]
Add one of a 720, 740,760,2020 and 2040 stations on the line during the MSL setup.
E3839 Coplanarity function is not available on this station.
[Cause]
Indicates that the specified station is not a 740,760,2020 or 2040 station, or the coplanarity is disabled
in the unit status during the MSL setup.
[Deal]
Make sure that the specified station is a 740,760,2020 or 2040 station, or the coplanarity is enabled
in the unit status during the MSL setup.
E3840 No station in the line can use coplanarity function.
[Cause]
Indicates that there is no 740,760,2020 or 2040 station on the line despite the coplanarity is enabled as