JUKI贴片机错误代码集合.pdf - 第283页
Please re-boot your machine. Please contact our technical serv ice dept. for information. E630219 “ Vision Syst em: It is unprescribed ERR code. ERR19 code ” “ 图像处理硬件错误 : 19 ” [Cause] Unprescribed error respons e was sen…
Please re-write the program in the IMGCPU.
Please re-boot your machine.
E630215 “Vision System: It is unprescribed ERR code. ERR15 code”
“图像处理硬件错误:|系统服务作业(System Service Task)发生超时”
[Cause]
Unprescribed error response was sent back from VCS.
Some program versions are clashing with each other.
[Treatment]
Please re-install or version up the application.
Please re-boot your machine.
Please contact our technical service dept. for information.
E630216 “Vision System: It is unprescribed ERR code. ERR16 code”
“图像处理硬件错误: 16”
[Cause]
Unprescribed error response was sent back from VCS.
Some program versions are clashing with each other.
[Treatment]
Please re-install or version up the application.
Please re-boot your machine.
Please contact our technical service dept. for information.
E630217 “Vision System: It is unprescribed ERR code. ERR17 code”
“图像处理硬件错误: 17”
[Cause]
Unprescribed error response was sent back from VCS.
Some program versions are clashing with each other.
[Treatment]
Please re-install or version up the application.
Please re-boot your machine.
Please contact our technical service dept. for information.
E630218 “Vision System: It is unprescribed ERR code. ERR18 code”
“图像处理硬件错误: 18”
[Cause]
Unprescribed error response was sent back from VCS.
Some program versions are clashing with each other.
[Treatment]
Please re-install or version up the application.
Please re-boot your machine.
Please contact our technical service dept. for information.
E630219 “Vision System: It is unprescribed ERR code. ERR19 code”
“图像处理硬件错误: 19”
[Cause]
Unprescribed error response was sent back from VCS.
Some program versions are clashing with each other.
[Treatment]
Please re-install or version up the application.
Please re-boot your machine.
Please contact our technical service dept. for information.
E630220 “Vision system hardware error: 20”
“图像处理硬件错误: 20”
E630300 “ViLib Thread: Other illogical matter occurred”
“图像<->ViLib I/F 错误:|发生其它不合理现象”
[Cause]
An unexpected error occurred in the vision device driver.
[Treatment]
Please re-boot your machine.
E630301 “ViLib Thread: Turnaround time-out occurred”
“图像<->ViLib I/F 错误:|应答超时”
[Cause]
There is no response from VCS.
[Treatment]
Please re-boot your machine.
E630999 “Vision Recognized error:| Other errors (detais unknown).”
“图像识别错误:|其它错误(未知详细错误)”
E631010 “ViRecog Error: No mark can be found. Please examine the PWB”
“标记识别错误:检查错误”
[Cause]
The actual mark coordinates are different from that in the data.
There is no mark on the board.
The ref. pin is not in the ref. hole properly.
A wrong board was loaded.
The light is not ON.
[Treatment]
Please re-teach the marks to the machine.
Please re-load a PWB.
Please re-load the production program.
Please examine if the light gets ON properly.
E631011 “ViRecog Error: The mark is touching the frame. Please examine Mark data”
“标记识别错误:标记不在窗口内”
[Cause]
The actual mark coordinates are different from that in the data.
The ref. pin is not in the ref. hole properly.
A wrong board was loaded.
[Treatment]
Please re-teach the marks to the machine.
Please re-load a PWB.
Please re-load the production program.
Please examine if the light gets ON properly.
E631012 “ViRecog Error: The consistency of the marks is too low. Please examine the PWB”
“标记识别错误:一致性错误”
[Cause]
The actual mark coordinates are different from that in the data.
There is no mark on the board.
The marks are critically dirty.
The ref. pin is not in the ref. hole properly.
A wrong board was loaded.
The light is not ON.
[Treatment]
Please examine the board.
Please re-load a PWB.
Please examine the marks.
Please re-teach the marks to the machine.
Please re-load the production program.
Please examine if the light gets ON properly.
E631013 “ViRecog Error: Other mark recognition error occurred. Please examine the mark data”
“标记识别错误:其它错误”
[Cause]
The actual mark coordinates are different from that in the data.
There is no mark on the board.