JUKI贴片机错误代码集合.pdf - 第29页

[Treatment] Please increase some memory av ailable by exiting unnecessary ap plications. E241001 “ Specified devi ce cannot be used ” “ 不能使用指定设备 ” [Cause] You could not go int o the teach ing mode since the device select…

100%1 / 464
选择设备出错。
E240022 The mark recognition error(FCS) [ %d point]
标记识别错误(FCS)[%d 个点]
I240400 There were %s mm difference with the measurement result.Please confirm.”
与测量结果有%s mm 之差。请确认一下。
I240401 Not measurement.Please confirm.”
不能测量。请确认一下。
Q240500 End tracking?
是否退出跟踪?
[Cause]
You are asked if to end the tracking process.
[Treatment]
If you want to end the process, press 'Yes'. If not, press 'No'.
Q240501 The position cannot be corrected. |Please push 'No' when you discontinue 'Yes' when correction is
not considered.”
存在不能执行坐标校正的电路。|忽视校正继续执行,请按[]﹔停止执行,请[]
Q240502 Is the measurement result reflected in the pickup data?|Please push 'No' when not reflect 'Yes' when
reflect.|Please push 'Cancel' when stop.”
是否把测量结果反映到吸着数据?|如果反映,请按[]﹔如果不反映,请按[]|如果
停止跟踪,请按[取消]
Q240503 Is the tracking position a correct place? |Please do 'Yes' when correct and do teaching pushing 'No'
when the mistake is found.||Please push 'Cancel' when stop.”
跟踪位置是否正确?|如果正确,请按[]﹔如果修正坐标,请按[]|如果停止跟踪,
请按[取消]
Q240504 The position cannot be corrected. |Please push 'No' when you discontinue 'Yes' when correction is
not considered.”
存在没有进行坐标校正的贴片点|果不想校正,继续执行,请按[]﹔如果要停止,
[]
E241000 Memory allocation error
分配内存错误
[Cause]
Failed to save the work area necessary to run a program or to create a window due to the shortage of
memory
[Treatment]
Please increase some memory available by exiting unnecessary applications.
E241001 Specified device cannot be used
不能使用指定设备
[Cause]
You could not go into the teaching mode since the device selected by HOD is not installed or is set to
not use.
[Treatment]
Please check the installation setting (an option of MS parameter) or the use setting (Use unit of
Machine Setup) of the selected device, and reselect a device available.
E241002 The station is different
站点不同
[Cause]
You could not go into the teaching mode since the device selected by HOD and the Pick data specify
different stations to use.
[Treatment]
Please reselect a correct device.
E241003 Specified position not move
不能移到指定坐标
[Cause]
You could not go into the teaching mode since you could not move to the specified position with the
device selected by HOD.
[Treatment]
Please reselect a device that is available to move to the specified position.
E241004 The input value is illegal (%s)
数据输入错误。(%s)
[Cause]
This is a program error. The specified value in the dialog became an illegal value.
‧ : A dialog item that is a cause of the error.
[Treatment]
Please close the dialog and try again. If the error occurs again even after the retry, please contact our
technical service dept. for information.
E241005 Index of component data has irregularities (%d)
组件索引错误。(%d)
[Cause]
The index number of the Component data is illegal. There is a possibility that the production program
is broken.
‧ : The index number of the Component data.
[Treatment]
Please examine the production program.
E241006 Measured component height has irregularities.(%s)
组件高度的测量结果错误。(%s)
E241007 Supply of the component is no TAPE.”
不属于带状元件。
E241008 Supply of the component is not assign
没有设置组件姿势。
[Cause]
'Component package' has not been set in the Component data.
[Treatment]
Please set 'Component package' in the Component data.
E241009 Centering of the component is no laser
不属于激光定中心组件。
[Cause]
'Centering method' has not been set to Laser centering in the Component data.
[Treatment]
Please set 'Centering method' to Laser centering in the Component data.
E241010 Centering of the component is not assign
没有设置定中心方式。
[Cause]
'Centering method' has not been set in the Component data.
[Treatment]
Please specify 'Centering method' in the Component data.
E241011 No pick data
吸取数据不存在。
[Cause]
There is no Pick data that is linked to the Component data.
[Treatment]
Please examine the production program.
E241012 There is no pick head.”
吸取头不存在。