JUKI贴片机错误代码集合.pdf - 第131页

E510010 “ Failed in the mail check ” “ 检查邮件失败。 ” [Cause] The software did not g et started properly. [Treatment] Please turn off the power supply of t he machine and reboot it. E510011 “ Failed in the mail rec eption ” “…

100%1 / 464
轴发生错误。
[Cause]
Something was wrong with axis movement.
[Treatment]
Please perform the Home returning.
E510005 The command error occurred
发生命令错误。
[Cause]
An UN-recognizable command was issued.
[Treatment]
A wrong version has been installed.
Please install the latest software.
E510006 Failed in the opening of the master schedule
打开主调度程序失败。
[Cause]
The software did not get started properly.
[Treatment]
Please turn off the power supply of the machine and reboot it.
E510007 Failed in create of the mail of the scheduler
创建调度程序邮件失败。
[Cause]
The software did not get started properly.
[Treatment]
Please turn off the power supply of the machine and reboot it.
E510008 Failed in the opening of the mail of the application-manager
打开程序管理邮件失败。
[Cause]
The software did not get started properly.
[Treatment]
Please turn off the power supply of the machine and reboot it.
E510009 Failed in the mail transmission to the application-manager
往程序管理发送邮件失败。
[Cause]
The software did not get started properly.
[Treatment]
Please turn off the power supply of the machine and reboot it.
E510010 Failed in the mail check
检查邮件失败。
[Cause]
The software did not get started properly.
[Treatment]
Please turn off the power supply of the machine and reboot it.
E510011 Failed in the mail reception
接收邮件失败。
[Cause]
The software did not get started properly.
[Treatment]
Please turn off the power supply of the machine and reboot it.
E510012 Failed in the opening of the mail of the production-control
打开生产管理邮件失败。
[Cause]
The software did not get started properly.
[Treatment]
Please turn off the power supply of the machine and reboot it.
E510013 Failed in the transmission of the mail to the production-control
往生产管理发送邮件失败。
[Cause]
The software did not get started properly.
[Treatment]
Please turn off the power supply of the machine and reboot it.
E510014 Failed in the opening of the command of the Trans-driver
打开传送驱动命令失败。
[Cause]
The software did not get started properly.
[Treatment]
Please turn off the power supply of the machine and reboot it.
E510015 Failed in the transmission of the command to the Trans-driver
往传送驱动器发送命令失败。
[Cause]
The software did not get started properly.
[Treatment]
Please turn off the power supply of the machine and reboot it.
E510016 Failed in the reception of the response from the Trans-driver
接收传送驱动器应答失败。
[Cause]
The software did not get started properly.
[Treatment]
Please turn off the power supply of the machine and reboot it.
E510017 Failed in the opening of the command of the sub-scheduler
打开次调度程序失败。
[Cause]
The software did not get started properly.
[Treatment]
Please turn off the power supply of the machine and reboot it.
E510018 Failed in the transmission of the command to the sub-scheduler
往次调度程序发送命令失败。
[Cause]
The software did not get started properly.
[Treatment]
Please turn off the power supply of the machine and reboot it.
E510019 Failed in the reception of the response from the sub-scheduler
接收次调度程序应答失败。
[Cause]
The software did not get started properly.
[Treatment]
Please turn off the power supply of the machine and reboot it.
E510020 Failed in the opening of the command of the XY-robot
打开 XY-Robot 命令失败。
[Cause]
The software did not get started properly.
[Treatment]
Please turn off the power supply of the machine and reboot it.
E510021 Failed in the transmission of the command to the XY-robot
XY-Robot 发送命令失败。
[Cause]
The software did not get started properly.
[Treatment]
Please turn off the power supply of the machine and reboot it.