JUKI贴片机错误代码集合.pdf - 第434页

[Cause] Indicates that the line has neither of a 710 nor 720 station on it, despite nozzles 1 to 4 are enabled in the part data. [Deal] Add either of a 710 or 720 station on the l ine during the MSL setup. E3847 No st at…

100%1 / 464
a part data inspection item.
[Deal]
Add a 740,760,2020 or 2040 station on the line during the MSL set
E3841 Verify function is not available on this station.
[Cause]
Indicates that the specified station is none of a 730, 740, 750 and 760 stations, or the verification is
disabled in the unit status during the MSL setup.
[Deal]
Make sure that the specified station is one of a 730, 740, 750 and 760 stations, or the verification is
enabled in the unit status during the MSL setup.
E3842 No station in the line can use verify function.
[Cause]
Indicates that the line has none of a 730, 740, 750,760 and 2000 series stations, despite the
verification is enabled in the unit status during the MSL setup.
[Deal]
Add one of a 730, 740, 750,760 and 2000 series stations on the line during the MSL setup.
E3843 No station in the line has laser centering.
[Cause]
Indicates that the line has none of 730, 740, 750,760 and 2000 series stations, despite the laser
centering is enabled in the part data.
[Deal]
Add one of 730, 740, 750,760, 2000 series and stations on the line during the MSL setup.
E3844 No station in the line has mechanical centering.
[Cause]
Indicates that the line has neither of a 710 nor 720 station on it, despite the mechanical centering is
enabled in the part data.
[Deal]
Add either of a 710 or 720 station on the line during the MSL setup.
E3845 No station in the line can use nozzle No.0.
[Cause]
Indicates that the line has neither of a 710 nor 720 station on it, despite nozzle 0 is enabled in the part
data.
[Deal]
Add either of a 710 or 720 station on the line during the MSL setup.
E3846 No station in the line can use nozzle No. 1 to 4.
[Cause]
Indicates that the line has neither of a 710 nor 720 station on it, despite nozzles 1 to 4 are enabled in
the part data.
[Deal]
Add either of a 710 or 720 station on the line during the MSL setup.
E3847 No station in the line can use nozzle No. 10 to 19.
[Cause]
Indicates that the line has neither of a 710 nor 720 station on it, despite nozzles 10 to 19 are enabled
in the part data.
[Deal]
Add either of a 710 or 720 station on the line during the MSL setup.
E3848 No station in the line can use nozzle No. 100 to 149.
[Cause]
Indicates that the line has none of 730, 740, 750 and 760 stations on it, despite nozzles 100 to 149
are enabled in the part data.
[Deal]
Add one of 730, 740, 750 and stations on the line during the MSL setup.
E3849 No station in the line can use nozzle No. 200 to 249.
[Cause]
Indicates that the line has a 740 and 760 stations on it, despite nozzles 200 to 249 are enabled in the
part data.
[Deal]
Add a 740 and/or 760 stations on the line during the MSL setup.
E3850 No station in the line can accept this nozzle.
[Cause]
The nozzle specified for the line is not located at the specified station.
[Deal]
Allocate the specified nozzle to another station or add the station you want to specify to the line with
the MSL Setup program.
E3851 No station in the line can accept components which height is more than 10mm.
[Cause]
Indicates that the line has none of 730, 740, 750,760,2010,2020 and 2040 stations.
[Deal]
Add one of 730, 740, 750,760,2010,2020 and 2040 stations on the line during the MSL setup.
E3852 No station in the line can accept components which width is more than 20mm.
[Cause]
Indicates that the line does not have one of 720, 740,760 and 2040 stations.
[Deal]
Add one of 720, 740,760 and 2040 stations on the line during the MSL setup.
E3853 Resource of bulk feeder is set to 0.
[Cause]
Indicates that the number of the specified bulk feeder types is set to 0 in the resource table during the
MSL setup.
[Deal]
Specify an appropriate value for the bulk feeder types in the resource table during the MSL setup.
E3854 Pick and place station assignment is different.
[Cause]
Indicates that different stations were specified between the mounting data and the absorption data.
[Deal]
Specify the same station or use the automatic selection.
E3855 The designated station does not support lane 8.
[Cause]
Lane 8 of the stick feeder is unavailable for a 710 or 720 station.
[Deal]
Specify another lane or specify a station capable of using the lane (730,740,750 or 760).
E3856 The designated station does not support No.5 nozzle.
[Cause]
Indicates that a 710 station cannot use nozzle 5.
[Deal]
Specify another nozzle or a station capable of using the lane (720).
E3857 The designated station does not support 44mm and 56mm width tape feeder.
[Cause]
Indicates that 44 or 56 mm is unavailable for a 710 station.
[Deal]
Specify another nozzle type, or use other station types (720, 730, 740,750,760) available for the
specified nozzle type.
E3858 The designated station does not support directed centering method.
[Cause]
The mechanical centering is only available for a 710 or 720 station, the vision centering, a 720,
740,760,2020 or 2040 station, and the laser centering, a 730, 740, 750,760 and 2000 series station.