JUKI贴片机错误代码集合.pdf - 第27页
[Cause] Home returning has not been complete yet. [Treatment] Please hit the ORIGIN button t o perform the Home returning, a nd try the process again. E240014 “ The Left OCC device is set i n unused by the setup ” “ 不能使用…
Something was wrong with the characters when you hit Enter key to define characters.
[Treatment]
Please re-enter characters
E240008 “There is no data previous”
“前面没有数据。”
[Cause]
This error occurs when there is no data ahead to trace.
[Treatment]
Check only
E240009 “There is no data next”
“后面没有数据。”
[Cause]
This error occurs when there is no data behind to trace.
[Treatment]
Check only
E240010 “Specified device cannot be used”
“指定设备不能使用。”
[Cause]
The specified device is set to “not use” in the Use unit in Setup.
[Treatment]
If the device is available, please set it to “use” in the Use unit in Setup. If not, this procedure cannot
be executed.
E240011 “The station is different”
“站点不同。”
[Cause]
This error occurs when the side the HOD device is on is wrong when teaching.
[Treatment]
Please check and see which device (left or right) to use.
E240012 “Specified position not move”
“不能移到指定坐标。”
[Cause]
You could not move the axis to the specified position since the axis went out of its movable range.
[Treatment]
Please check and see if the coordinates are correct.
E240013 “The origin point return is non-completion”尚未结束返回原点。”
[Cause]
Home returning has not been complete yet.
[Treatment]
Please hit the ORIGIN button to perform the Home returning, and try the process again.
E240014 “The Left OCC device is set in unused by the setup”
“不能使用左 OCC。”
[Cause]
The Left OCC device is set to “not use” in the Use unit in Setup.
[Treatment]
If the device is available, please set it to “use” in the Use unit in Setup. If not, this procedure cannot
be executed.
E240015 “The Right OCC device is set in unused by the setup”
“不能使用右 OCC。”
[Cause]
The Right OCC device is set to “not use” in the Use unit in Setup.
[Treatment]
If the device is available, please set it to “use” in the Use unit in Setup. If not, this procedure cannot
be executed.
E240016 “The HMS device is set in unused by the setup”
“不能使用 HMS。”
[Cause]
The HMS device is set to “not use” in the Use unit in Setup.
[Treatment]
If the device is available, please set it to “use” in the Use unit in Setup. If not, this procedure cannot
be executed.
E240017 “The SOT direction inspection not execute.”
不能执行 SOT 方向检查。”
E240018 “The verification inspection not execute.”
“不能执行数值检查。”
E240019 “Area fiducial mark recognition error [ L side PWB / %d point]”
“基板基准标记识别错误[ 左侧基板 / 第%d 个点] “
E240020 “Area fiducial mark recognition error [ R side PWB / %d point]”
“基板基准标记识别错误[ 右侧基板 / 第%d 个点] “
E240021 “Device selection is mistake.”
“选择设备出错。 “
E240022 “The mark recognition error(FCS) [ %d point]”
“标记识别错误(FCS)[第%d 个点] “
I240400 “There were %s mm difference with the measurement result.Please confirm.”
“与测量结果有%s mm 之差。请确认一下。”
I240401 “Not measurement.Please confirm.”
“不能测量。请确认一下。”
Q240500 “End tracking?”
“是否退出跟踪?”
[Cause]
You are asked if to end the tracking process.
[Treatment]
If you want to end the process, press 'Yes'. If not, press 'No'.
Q240501 “The position cannot be corrected. |Please push 'No' when you discontinue 'Yes' when correction is
not considered.”
“存在不能执行坐标校正的电路。|忽视校正继续执行,请按[是]﹔停止执行,请按[否]。”
Q240502 “Is the measurement result reflected in the pickup data?|Please push 'No' when not reflect 'Yes' when
reflect.|Please push 'Cancel' when stop.”
“是否把测量结果反映到吸着数据?|如果反映,请按[是]﹔如果不反映,请按[否]。|如果
停止跟踪,请按[取消]。”
Q240503 “Is the tracking position a correct place? |Please do 'Yes' when correct and do teaching pushing 'No'
when the mistake is found.||Please push 'Cancel' when stop.”
“跟踪位置是否正确?|如果正确,请按[是]﹔如果修正坐标,请按[否]。|如果停止跟踪,
请按[取消]。”
Q240504 “The position cannot be corrected. |Please push 'No' when you discontinue 'Yes' when correction is
not considered.”
“ 存在没有进行坐标校正的贴片点|如果不想校正,继续执行,请按[是]﹔如果要停止,请
按[否]。 “
E241000 “Memory allocation error”
“分配内存错误”
[Cause]
Failed to save the work area necessary to run a program or to create a window due to the shortage of
memory