JUKI贴片机错误代码集合.pdf - 第371页

The parameter to control probe is not correct. [Treatment] ‧Plea se re-start the application. ‧Please re-install or version-up the application. ‧If the error occurs even afte r the treat ments above were perf ormed, plea…

100%1 / 464
E690001 CVS is not installed
未设置 CVS
[Cause]
CVS is not installed on the machine.
[Treatment]
‧If CVS is actually installed on your machine, please enable the unit in the MS parameter option.
E690002 Impossible to switch to Resistance Measurement mode since the probe has not shut down. | Please
shut the probe down then try again
因探针没有被关闭,不能切换到测定电阻模式。|请关闭探针后再执行。
[Cause]
In order to set measurement mode to the Resistance mode, the probe has to be closed to adjust
resistance.
‧The probe is not closed.
[Treatment]
‧Please close the probe then set the measurement mode.
E690003 Impossible to switch to Condenser Measurement mode since the probe has not shut down. | Please
shut the probe down then try again
因探针没有被打开,不能切换到测定电容模式。|请打开探针后再执行。
[Cause]
In order to set measurement mode to the Condenser mode, the probe has to be closed to adjust
capacity.
‧The probe is not closed.
[Treatment]
‧Please close the probe then set the measurement mode.
E690004 The measurement mode is not correct
测定模式不正确。
[Cause]
The measurement mode parameter is not correct.
[Treatment]
‧Please re-start the application.
‧Please re-install or version-up the application.
If the error occurs even after the treatments above were performed, please contact our technical
service dept. for information.
E690005 Parameter to control probe is not correct
控制探针参数不正确。
[Cause]
The parameter to control probe is not correct.
[Treatment]
‧Please re-start the application.
‧Please re-install or version-up the application.
‧If the error occurs even after the treatments above were performed, please contact our technical
service dept. for information.
E690006 Probe has to be shut down to measure resistance. | Please shut probe then try again
不关闭探针,就不能测定电阻。|请关闭探针后执行。
[Cause]
In order to measurement resistance, the probe has to be closed.
The probe is not closed.
‧The probe is not closed.
[Treatment]
‧Please close the probe then measure the resistance.
E690007 Probe has to be shut down to measure condenser. | Please shut probe then try again
不关闭探针,就不能测定电容。|请关闭探针后执行。
[Cause]
In order to measurement condenser capacity, the probe has to be closed.
The probe is not closed.
‧The probe is not closed.
[Treatment]
‧Please close the probe then measure the condenser capacity.
E690008 Diode measurement is not available unless probe shuts down. | Please shut probe then try again
不关闭探针,就不能测定电流方向|请关闭探针后执行。
[Cause]
The probe has to be closed to measure diode polarity.
‧The probe is not closed.
[Treatment]
‧Please close the probe then try the measurement.
E690009 The measurement is impossible since measurement mode is not set to Resistance measurement. |
Please switch to the Resistance measurement mode then try again
因为不是测定电阻模式,不能测定电阻。|请切换到测定电阻模式后执行。
[Cause]
In order to measure resistance, the measurement mode has to be the Resistance measurement mode.
‧Measurement mode is not set to the Resistance measurement mode.
[Treatment]
‧Please set the measurement mode to the Resistance measurement mode and try again.
E690010 The measurement is impossible since measurement mode is not set to Condenser measurement. |
Please switch to the Condenser measurement mode then try again
因为不是测定电容模式,不能测定电容。|请切换到测定电容模式后执行。
[Cause]
In order to measure condenser capacity, the measurement mode has to be the Condenser measurement
mode.
‧Measurement mode is not set to the Condenser measurement mode.
[Treatment]
‧Please set the measurement mode to the Condenser measurement mode and try again.
E690011 The measurement is impossible since measurement mode is not set to Diode measurement. | Please
switch to the Diode measurement mode then try again
因为不是测定电流方向模式,不能测定电流方向。|请切换到测定电流方向模式后执行。
[Cause]
In order to measure diode polarity, the measurement mode has to be the Diode measurement mode.
‧Measurement mode is not set to the Diode measurement mode.
[Treatment]
‧Please set the measurement mode to the Diode measurement mode and try again
E690012 The measurement is impossible since the gotten measurement mode is set to Resistance
measurement
因为采取的模式不是测定电阻模式,所以不能测定电阻。
[Cause]
The measurement mode gotten from the tester is not the Resistance measurement.
The specified measurement mode and the measurement mode gotten from the tester are clashing
with each other.
‧The Component Verification is broken.
[Treatment]
‧If the error occurs even after a re-try, please turn off the power supply and re-boot your machine.
‧If the error occurs even after the re-boot, there is a possibility that the Component Verification
unit is broken. Please contact our technical service dept. for information.
E690013 The measurement is impossible since the gotten measurement mode is set to Condenser
measurement
因为采取的模式不是测定电容模式,所以不能测定电容。
[Cause]
The measurement mode gotten from the tester is not the Condenser measurement.
The specified measurement mode and the measurement mode gotten from the tester are clashing