JUKI贴片机错误代码集合.pdf - 第372页

‧Plea se set the measurement mode to the Resistance measurement mode and try again. E690010 “ The measurement is impossible si nce measurement mode is not set to Condenser measurement. | Please switch to the Condenser me…

100%1 / 464
The parameter to control probe is not correct.
[Treatment]
‧Please re-start the application.
‧Please re-install or version-up the application.
‧If the error occurs even after the treatments above were performed, please contact our technical
service dept. for information.
E690006 Probe has to be shut down to measure resistance. | Please shut probe then try again
不关闭探针,就不能测定电阻。|请关闭探针后执行。
[Cause]
In order to measurement resistance, the probe has to be closed.
The probe is not closed.
‧The probe is not closed.
[Treatment]
‧Please close the probe then measure the resistance.
E690007 Probe has to be shut down to measure condenser. | Please shut probe then try again
不关闭探针,就不能测定电容。|请关闭探针后执行。
[Cause]
In order to measurement condenser capacity, the probe has to be closed.
The probe is not closed.
‧The probe is not closed.
[Treatment]
‧Please close the probe then measure the condenser capacity.
E690008 Diode measurement is not available unless probe shuts down. | Please shut probe then try again
不关闭探针,就不能测定电流方向|请关闭探针后执行。
[Cause]
The probe has to be closed to measure diode polarity.
‧The probe is not closed.
[Treatment]
‧Please close the probe then try the measurement.
E690009 The measurement is impossible since measurement mode is not set to Resistance measurement. |
Please switch to the Resistance measurement mode then try again
因为不是测定电阻模式,不能测定电阻。|请切换到测定电阻模式后执行。
[Cause]
In order to measure resistance, the measurement mode has to be the Resistance measurement mode.
‧Measurement mode is not set to the Resistance measurement mode.
[Treatment]
‧Please set the measurement mode to the Resistance measurement mode and try again.
E690010 The measurement is impossible since measurement mode is not set to Condenser measurement. |
Please switch to the Condenser measurement mode then try again
因为不是测定电容模式,不能测定电容。|请切换到测定电容模式后执行。
[Cause]
In order to measure condenser capacity, the measurement mode has to be the Condenser measurement
mode.
‧Measurement mode is not set to the Condenser measurement mode.
[Treatment]
‧Please set the measurement mode to the Condenser measurement mode and try again.
E690011 The measurement is impossible since measurement mode is not set to Diode measurement. | Please
switch to the Diode measurement mode then try again
因为不是测定电流方向模式,不能测定电流方向。|请切换到测定电流方向模式后执行。
[Cause]
In order to measure diode polarity, the measurement mode has to be the Diode measurement mode.
‧Measurement mode is not set to the Diode measurement mode.
[Treatment]
‧Please set the measurement mode to the Diode measurement mode and try again
E690012 The measurement is impossible since the gotten measurement mode is set to Resistance
measurement
因为采取的模式不是测定电阻模式,所以不能测定电阻。
[Cause]
The measurement mode gotten from the tester is not the Resistance measurement.
The specified measurement mode and the measurement mode gotten from the tester are clashing
with each other.
‧The Component Verification is broken.
[Treatment]
‧If the error occurs even after a re-try, please turn off the power supply and re-boot your machine.
‧If the error occurs even after the re-boot, there is a possibility that the Component Verification
unit is broken. Please contact our technical service dept. for information.
E690013 The measurement is impossible since the gotten measurement mode is set to Condenser
measurement
因为采取的模式不是测定电容模式,所以不能测定电容。
[Cause]
The measurement mode gotten from the tester is not the Condenser measurement.
The specified measurement mode and the measurement mode gotten from the tester are clashing
with each other.
The Component Verification is broken.
[Treatment]
‧If the error occurs even after a re-try, please turn off the power supply and re-boot your machine.
‧If the error occurs even after the re-boot, there is a possibility that the Component Verification
unit is broken. Please contact our technical service dept. for information.
E690014 The measurement is impossible since the gotten measurement mode is set to Diode measurement
因为采取的模式不是测定电流方向模式,所以不能测定电流方向。
[Cause]
The measurement mode gotten from the tester is not the Diode measurement.
The specified measurement mode and the measurement mode gotten from the tester are clashing
with each other.
The Component Verification is broken.
[Treatment]
‧If the error occurs even after a re-try, please turn off the power supply and re-boot your machine.
‧If the error occurs even after the re-boot, there is a possibility that the Component Verification
unit is broken. Please contact our technical service dept. for information.
E690015 The resistance when zero-adjusting is abnormal. | Please check if probe short-circuits or not
零位电阻有些异常。|请检查一下探针是否短路。
[Cause]
The resistance that was gotten from the tester when adjusting the resistance is irregular.
‧The probe does not short-circuit.
‧An obstruction that has resistance is caught in the probe.
‧The Component Verification is broken.
[Treatment]
‧Please check and see if the probe short-circuits.
‧If the error occurs when the probe does not have any problems, please turn off the power supply
and re-boot your machine.
‧If the error occurs even after the re-boot, there is a possibility that the Component Verification
unit is broken. Please contact our technical service dept. for information.
E690016 A time-out occurred while reading resistance in
读取电阻超时。
[Cause]
The tester does not start outputting data when starting to measure the resistance.
‧Component Verification is broken.
[Treatment]
‧Please turn off the power supply and re-boot your machine.