unit is broken. Ple ase contact our technical service dept. for information. E690030 “ Voltage can not be measured. | Please check if probe shuts down properly ” “ 不能测定电压。 | 请检查探针是否已关 闭。 ” [Cause] The tester overflowed d…
“测定的电压(单位)有些异常。”
[Cause]
The unit for the voltage gotten from the tester is irregular.
‧The object(component) of the measurement is not contacting the probe well.
‧Component Verification is broken.
[Treatment]
‧Please check and see if the object is contacting the probe well. If not, please adjust the position of
the object to contact the probe properly.
‧If the error occurs when the contact is good, there is a possibility that the Component Verification
unit is broken. Please contact our technical service dept. for information.
E690028 “Resistance can no be measured. | Please check if probe shuts down properly”
“不能测定电阻。|请检查探针是否已关闭。”
[Cause]
The tester overflowed data when measuring the resistance.
‧The object(component) of the measurement is not contacting the probe.
‧The contact between the object(component) of the measurement and the probe is not good.
‧The resistance of the object(component) of the measurement is exceeding the measurement range.
‧The Component Verification is broken.
[Treatment]
‧Please check and see if the object is contacting the probe well. If not, please adjust the position of
the object to contact the probe properly.
‧Please check the object.
‧If the error occurs when the contact is good, there is a possibility that the Component Verification
unit is broken. Please contact our technical service dept. for information.
E690029 “Volume can not be measured. | Please check if probe shuts down properly”
“不能测定电容。|请检查探针是否已关闭。”
[Cause]
The tester overflowed data when measuring the condenser capacity.
‧The object(component) of the measurement is not contacting the probe.
‧The contact between the object(component) of the measurement and the probe is not good.
‧The resistance of the object(component) of the measurement is exceeding the measurement range.
‧The Component Verification is broken.
[Treatment]
‧Please check and see if the object is contacting the probe well. If not, please adjust the position of
the object to contact the probe properly.
‧Please check the object.
‧If the error occurs when the contact is good, there is a possibility that the Component Verification
unit is broken. Please contact our technical service dept. for information.
E690030 “Voltage can not be measured. | Please check if probe shuts down properly”
“不能测定电压。|请检查探针是否已关闭。”
[Cause]
The tester overflowed data when measuring the diode polarity.
‧The object(component) of the measurement is not contacting the probe.
‧The contact between the object(component) of the measurement and the probe is not good.
‧The resistance of the object(component) of the measurement is exceeding the measurement range.
‧The Component Verification is broken.
[Treatment]
‧Please check and see if the object is contacting the probe well. If not, please adjust the position of
the object to contact the probe properly.
‧Please check the object.
If the error occurs when the contact is good, there is a possibility that the Component Verification
unit is broken. Please contact our technical service dept. for information.
E690031 “The power supply of the tester cannot be turned on.”
“不能打开测试器电源。”
E690032 “Since air is falling, control of a probe is stopped.”
“因为大气压太低,所以停止探针的控制。”
E691001 “Input/Output buffer status of CCL-48M does not get ready”
“CCL-48M的I/O缓冲区不能达到就绪状态。”
[Cause]
The input/output buffer status of the backup table counter(CCL-48M) does not get ready.
‧Backup table counter is broken.
[Treatment]
‧Please turn off the power supply and re-boot your machine.
‧If the error occurs even after the re-boot, there is a possibility that the Safety board is broken.
Please contact our technical service dept. for information.
E691002 “Writing-in buffer of flush memory does not get useable”
“不能使用闪存卡的写入缓冲区。”
[Cause]
'Writing-in' buffer did not get useable when checking its status after a 'writing-in' command to flush
memory was issued.
‧Flush memory is broken.
[Treatment]
‧Please turn off the power supply and re-boot your machine.
‧If the error occurs even after the re-boot, there is a possibility that the Safety board is broken.
Please contact our technical service dept. for information.
E691003 “Deleting cue of flush memory does not get useable”
“不能使用闪存卡的删除指令。”
[Cause]
'Deleting' cue did not get useable when checking its status after a 'deleting' command to flush memory
was issued.
‧Flush memory is broken.
[Treatment]
‧Please turn off the power supply and re-boot your machine.
‧If the error occurs even after the re-boot, there is a possibility that the Safety board is broken.
Please contact our technical service dept. for information.
E691004 “WSM(Write State Machine) of flush memory does not get ready”
“闪存卡的WSM(Write State Machine)不能达到就绪状态。”
[Cause]
'WSM' did not get ready when checking its status after a command to flush memory was issued.
‧Flush memory is broken.
[Treatment]
‧Please turn off the power supply and re-boot your machine.
‧If the error occurs even after the re-boot, there is a possibility that the Safety board is broken.
Please contact our technical service dept. for information.
E691005 “Write-in voltage range error occurred in flush memory control”
“闪存卡控制中发生写入电压范围错误。”
[Cause]
An error occurred while checking the 'Write-in' voltage status after a command to flush memory was
issued.
The process was aborted since the 'write-in' voltage is too low.
‧Flush memory is broken.
[Treatment]
‧Please turn off the power supply and re-boot your machine.
‧If the error occurs even after the re-boot, there is a possibility that the Safety board is broken.
Please contact our technical service dept. for information.
E691006 “Write-in error occurred in flush memory control”
“闪存卡控制中发生设备保护错误。”
[Cause]
An error occurred while checking the 'device protecting' status after a command to flush memory was