[Cause] An assemblage position offset of a measured head exceeded the l imit value. The limit is: -9.9999 through 9.9999 [Treatment] System error Please check the MS parameter. E906021 “ Return to home has not yet been c…

100%1 / 464
I904012 It failed to upgrade.”
版本升级失败。
I904013 The program data on I/O CPU has successfully been deleted.”
I/O CPU程序数据删除完毕。
I904014 Failed to delete the program data on I/O CPU.”
删除I/O CPU程序数据失败。
I904015 The program data on B/F CPU has successfully been deleted.”
B/F CPU程序数据删除完毕。
I904016 Failed to delete the program data on B/F CPU.”
删除B/F CPU程序数据失败。
I904017 Gauge Block is set on R1.|R1 moves to jig installing position by selecting 'OK'.”
测量器被安装在R1|向取下它的位置移动。
I904030 Juki vision system is %s.”
图像处理装置的版本是%s
I904040 Succeeded in the format of the flash memory of Juki vision system.
图像处理装置闪存卡的格式化结束
I904041 Failed in the format of the flash memory of Juki vision system.
图像处理装置闪存卡的格式化失败
E906001 Memory allocation error
内存分配错误。
[Cause]
The working space can not be saved.
[Treatment]
Please increase some more memory available to save the working space.
E906002 Shared memory open error
打开共享内存错误。
[Cause]
The shared memory could not be open.
[Treatment]
Please shut down the your machine and re-start it.
E906011 Measurement result exceeds limit value. Check the MS parameter
测量结果超过界限。|请检查一下MS参数。
[Cause]
An assemblage position offset of a measured head exceeded the limit value. The limit is: -9.9999
through 9.9999
[Treatment]
System error
Please check the MS parameter.
E906021 Return to home has not yet been completed
尚未结束返回原点。
[Cause]
The axis has not yet been returned to home.
[Treatment]
Please perform the Return to home with ORIGIN switch.
E906022 Servo is in the free state
伺服处于未使用状态。
[Cause]
The axis could not move since the servo is not locked.
[Treatment]
Please lock the servo with S-FREE switch.
E906031 Selected device is not install. Please reselect other device on HOD
没有安装被选设备。|请重新选择其它设备。
[Cause]
You could not go into the teaching mode since the device selected by HOD has not been installed.
[Treatment]
Please reselect the device which is currently installed.
E906041 There is no installed head
不存在可用Head
[Cause]
You could not specify a head since there is no head available.
[Treatment]
Please set to use in the Use unit setting in Machine Setup.
E906042 There is no installed VCS
不存在可用VCS
[Cause]
You could not specify VCS since no VCS has been installed or there is no VCS available.
[Treatment]
Your request is not available on the machine that do not have VCS. If your machine has VCS, please
set the VCS to Use in the Use unit setting in Machine Setup.
E906043 %s is disable. Selected unit can not measure
%s是无效设备。|被选单元不能测量。
[Cause]
The selected head is set to not use in the Use unit setting in Machine Setup.
[Treatment]
Please set the head to use in the Use unit setting in Machine Setup.
E906051 No nozzle 501 or 502 are present in ATC. Add either nozzle using ATC setup
500, 501号及502号吸嘴没有安装在ATC|请利用机器设置的ATC吸嘴分配,设置吸嘴。
[Cause]
501 nozzle and 502 nozzle have not been allocated to ATC. Please allocated a nozzle using the ATC
nozzle allocation in Machine Setup.
[Treatment]
Please assign 501 nozzle or 502 nozzle to ATC in the ATC nozzle allocation in Machine Setup.
E906052 No nozzle 508 or 507 are present in ATC. Add either nozzle using ATC setup
508号及507号吸嘴没有安装在ATC|请利用机器设置的ATC吸嘴分配,设置吸嘴。
[Cause]
508 nozzle and 507 nozzle have not been allocated to ATC. Please allocated a nozzle using the ATC
nozzle allocation in Machine Setup.
[Treatment]
Please assign 507 nozzle or 508 nozzle to ATC in the ATC nozzle allocation in Machine Setup.
E906061 Mark on calibration jig for laser alignment has not been acknowledged. Check the position of jig
不能识别激光校准用校准模具的标记。|请确认一下模具位置。
[Cause]
The mark on the Calibration jig for laser alignment could not be recognized. The position at where
the Calibration jig has been set may be wrong or something is wrong with VCS.
[Treatment]
Please check the jig position and see if the jig is set to be able to see the first mark and second mark
illuminations of the Calibration block from the two holes on the jig. If the jig position is correct, then
something may be wrong with VCS.
E906062 Mark on calibration jig for laser alignment has not been acknowledged
不能识别激光校准用校准模具的标记。
[Cause]
The mark on the Calibration jig for laser alignment could not be recognized. The position at where
the Calibration jig has been installed may be wrong or something is wrong with the vision unit.
[Treatment]