JUKI贴片机错误代码集合.pdf - 第400页
[Cause] Failed to pick up the Calibrati on jig for VCS. An out-of-compon ent error occurred in the Laser recognition of the Calibrat ion jig for VCS. [Treatment] Please check and see if the Ca libration jig for laser al …
Please check the position of the Calibration jig for laser alignment, which is installed on the
Calibration block. If the position is correct, then something might be wrong with the vision unit.
E906071 “Calibration jig for laser alignment has not been picked up. Check that jig is placed on calibration
jig”
“不能吸取激光校准用校准模具。|请确认一下模具是否置于校准块上面。”
[Cause]
Failed to pick up the Calibration jig for laser alignment. An Out-of-component error occurred in the
Laser recognition of the Calibration jig for laser alignment.
[Treatment]
Please check and see if the Calibration jig for laser alignment is placed on the Calibration block.
E906072 “Calibration jig for laser alignment has not been picked up. Check that jig is placed on jig station”
“不能吸取激光校准用校准模具。|请确认一下模具是否置于模具站点上面。”
[Cause]
Failed to pick up the Calibration jig for laser alignment. An out-of-component error occurred in the
Laser recognition of the Calibration jig for laser alignment.
[Treatment]
Please check and see if the Calibration jig for laser alignment is placed on the Calibration station.
E906073 “Error between the locations of jig placed and calibration block exceeds limit value. Check the MS
parameter”
“模具的贴片位置和校准块位置的误差超过界限值。|请检查一下MS参数。”
[Cause]
After measuring the assemblage position offset of a head, the Calibration jig for laser alignment was
placed on the center of the Calibration block.. The placement position deviated from the Calibration
block by more than 1.
[Treatment]
System error
Please check the MS parameter.
E906074 “Position of calibration jig for laser alignment has irregularities. Check the position of jig”
“激光校准用校准模具的位置有些异常。|请确认一下模具位置。”
[Cause]
The position of the Calibration jig for laser alignment on the Calibration block is irregular.
The center of the recognized mark is more than 0.5mm far from the center of the Calibration block..
[Treatment]
Please place the jig to make the recognized mark 'circular'.
E906075 “Calibration jig for VCS has not been picked up. Check that jig is placed on jig station”
“不能吸取VCS用校准模具。|请确认一下模具是否置于模具站点上面。”
[Cause]
Failed to pick up the Calibration jig for VCS. An out-of-component error occurred in the Laser
recognition of the Calibration jig for VCS.
[Treatment]
Please check and see if the Calibration jig for laser alignment is placed on the Calibration station.
E906101 “Error has occurred when detecting height of measuring plane of laser | code:%ld”
“检测激光测量高度发生错误。|代码: %ld”
[Cause]
An error occurred when measuring the height by laser.
1: Error code
2: The shadow does not get clear when lifting Z axis up.
3: There is not shadow when lowering Z axis down.
4: After detecting a shadow once, Z axis was lifted up but thshadow does not get clear.
5: A communication error occurred.
6: An axis error occurred.
[Treatment]
Something may be wrong with the Laser alignment. Please check the Laser alignment.
E906102 “Error has occurred during laser measurement(ONCE) | code:%ld”
“设置激光参数发生错误。|代码: %ld”
[Cause]
An abnormal matter happened in the Parameter setting of Laser.
1): Error code.
2): A communication error occurred.
[Treatment]
Please contact our technical service dept. for information.
E906103 “Error has occurred during laser measurement(ONCE) | code:%ld”
“激光测量(ONCE)发生错误。|代码: %ld”
[Cause]
An error occurred during the measurement (ONCE) by laser.
1): Error code.
2): A communication error.
[Treatment]
Please contact our technical service dept. for information.
E906104 “Error has occurred during laser measurement (SWEEP) | code:%ld”
“激光测量(SWEEP)发生错误。|代码: %ld “
[Cause]
An error occurred during the measurement(SWEEP) by laser.
1): Error code
2): A communication error occurred.
3): An axis error occurred.
[Treatment]
Please contact our technical service dept. for information.
E906105 “Error has occurred during the component presence check | code: %ld”
“检查组件存在状况发生错误。|代码: %ld”
[Cause]
A communication error occurred during the component presence check.
[Treatment]
Please contact our technical service dept. for information.
E906201 “Error has occurred during acknowledgment of mark”
“标记识别错误。”
[Cause]
An error occurred during the Mark recognition by a vision unit.
[Treatment]
Please check and see if the recognition requirements are correct and if the focus and tone of the
camera are well adjusted. If this error occurs even after checking the requirements and adjustment,
then something might be wrong with vision unit. Please check the vision unit.
E906301 “Error has occurred on axis | code:%ld”
“轴发生错误。|代码: %ld”
[Cause]
An error occurred while an axis was traveling.
[Treatment]
W906401 “1.Vacuum generating power of ejector is beyond regular level.|Ejectors need to be changed.|2.Air is
leaking from the air pipe path.|Air paths need to be inspected.|3.Main air pressure is too low.|Check
the pressure.”
“1.真空发生器的吸引力偏高。|需要更换发生器。|2.发生空气管道漏气。|需要检查空气管
道。|3.发生气压偏低。|需要检查气压。”
W906402 “1.Vacuum generating power of ejector is low.|Ejectors need to be changed.|2.Air is leaking from
the air pipe path.|Air paths need to be inspected.”
“1.真空发生器的吸引力偏低。|需要更换排出器。|2.发生空气管道漏气。|需要检查空气管
道。”
W906403 “1.Stuff in the air filter on the nozzle axis side.|Air filters need to be changed.”