JUKI贴片机错误代码集合.pdf - 第366页
“ 基板固定错误 : | 出口侧中心缓冲区没有被选用。 ” W650701 “ Reclamp error :| There is no PWB on the STOP sensor. | Please c onfirm the position of the PWB .” “ 重新固定错误 : | 在停止传感器上面,没有发现基板。 | 请确认一下基板位置 。 ” E650702 “ Recl amp error :| The poin…
occurred.
If the OUT sensor does not get OFF when a PWB is properly being conveyed, there is a possibility
that the sensor is detecting something else. Please select [Manual Control] from the menu bar, and
then select [Control(C)] [Conveyor(C)] [Independent Control of Conveyor(I)] to see the status of
OUT sensor in the 'Status' frame.
1) If there is anything that OUT sensor reacts to underneath the OUT sensor, please remove it from
under the sensor or change the position of the sensor.
2) If the treatment1 does not work, please re-adjust the sensitivity of the sensor, using the volume
control knob attached to the sensor.
3) If the treatment2 does not work, there is a possibility that the OUT sensor is broken. It could be
that the wiring came off the connector part, that a contact pin in the connector part is broken, that
wiring got cut off, or that the sensor itself is broken. Please examine the wiring and the connector. If
any of them are broken, you need to replace them with new ones.
4) If the treatment3 does not work, a PCB is broken or the wiring between the PCBs is bad.
E650366 “Idle PWB Conveying Error :| Shutter time out error of Output buffer. | Please remove it.”
“传送基板(通过)错误 :|出口快门超时。”
E650367 “Idle PWB Conveying Error :| PWB conveying error of Output buffer. | Please remove it.”
“传送基板(通过)错误 :|出口缓冲区的基板搬入出错。”
W650401 “Clamp error :| Backup plate stopper is ON. | Please Turn Off Backup plate stopper.”
“基板固定错误 :|支撑台停止挡销被打开。|请关闭支撑台停止挡销。”
W650402 “Clamp error :| Backup plate stopper is specification not used.”
“基板固定错误 :|支撑台停止挡销没有被选用。”
W650421 “Clamp error :| Backup plate stopper is ON. | Please Turn Off Backup plate stopper.”
“基板固定错误 :|入口侧中心缓冲区的支撑台停止挡销被打开。|请关闭支撑台停止挡销。”
W650422 “Clamp error :| Backup plate stopper is specification not used.”
“基板固定错误 :|入口侧中心缓冲区的支撑台停止挡销没有被选用。”
W650423 “Clamp error :| In buffer is specification not used.”
“基板固定错误 :|入口侧中心缓冲区没有被选用。”
W650441 “Clamp error :| Backup plate stopper is ON. | Please Turn Off Backup plate stopper.”
“基板固定错误 :|出口侧中心缓冲区的支撑台停止挡销被打开。|请关闭支撑台停止挡销。”
W650442 “Clamp error :| Backup plate stopper is specification not used.”
“基板固定错误 :|出口侧中心缓冲区的支撑台停止挡销没有被选用。”
W650443 “Clamp error :| Out buffer is specification not used.”
“基板固定错误 :|出口侧中心缓冲区没有被选用。”
W650701 “Reclamp error :| There is no PWB on the STOP sensor. | Please confirm the position of the PWB.”
“重新固定错误 :|在停止传感器上面,没有发现基板。|请确认一下基板位置。”
E650702 “Reclamp error :| The point of the PWB was not able to be detected.”
“重新固定错误 :|未查出基板前沿。”
E650703 “Reclamp error :| The point of the PWB was not able to be detected.”
“重新固定错误 :|未查出基板前沿。”
E650704 “Reclamp error :| The PWB is being clamped. | It is not possible to clamp again.”
“重新固定错误 :|基板处于固定状态。|不能重新固定。”
W650711 “Reclamp Error :| PWB was detected with the C.OUT sensor. | Please move PWB to the OUT
buffer”
“重新固定错误 :|C.OUT传感器发现基板。|请移走出口缓冲区的基板 “
W650731 “Reclamp error :| In buffer is no PWB on the STOP sensor. | Please confirm the position of the
PWB.”
“重新固定错误 :|入口侧中心缓冲区的停止传感器上,不存在基板。|请确认一下基板位置。”
E650732 “Reclamp error :| The point of the In buffer PWB was not able to be detected.”
“重新固定错误 :|未查出入口侧中心缓冲区的基板前沿。”
E650733 “Reclamp error :| The point of the In buffer PWB was not able to be detected.”
“重新固定错误 :|未查出入口侧中心缓冲区的基板前沿。”
E650734 “Reclamp error :| The PWB is being clamped. | It is not possible to clamp again.”
“重新固定错误 :|入口侧中心缓冲区的基板处于固定状态。|不能重新固定。”
W650761 “Reclamp error :| Out buffer is no PWB on the STOP sensor. | Please confirm the position of the
PWB.”
“重新固定错误 :|出口侧中心缓冲区的停止传感器上,不存在基板。|请确认一下基板位置。”
E650762 “Reclamp error :| The point of the Out buffer PWB was not able to be detected.”
“重新固定错误 :|未查出出口侧中心缓冲区的基板前沿。”
E650763 “Reclamp error :| The point of the Out buffer PWB was not able to be detected.”
“重新固定错误 :|未查出出口侧中心缓冲区的基板前沿。”
E650764 “Reclamp error :| The PWB is being clamped. | It is not possible to clamp again.”
“重新固定错误 :|出口侧中心缓冲区的基板处于固定状态。|不能重新固定。”
W650791 “Reclamp error :| There is not enough distance in the operation of the re-clamping.”
“重新固定错误 :|重新固定动作所需的移动距离不够长。”
W650792 “Reclamp error :| The state of the WAIT sensor changed when the re-clamping operated.”
“重新固定错误 :|重新固定动作时,等待传感器状态已变更。”
E651001 “Returning to ORIGIN has not been done”
“未完成返回原点。”
[Cause]
Returning to ORIGIN of Auto. PWB Width Alignment control has not been complete.
‧In order to adjust the Auto. PWB Width Alignment control, ORIGIN returning has to be done.
[Treatment]
‧Please complete the ORIGIN returning by pressing the ORIGIN button.
E651002 “An error occurred when returning to ORIGIN”
“返回原点发生错误。”
[Cause]
An error occurred while Auto. PWB Width Alignment control was returning to its ORIGIN.
[Treatment]
lease turn off the power supply of your machine and re-boot it. If the error occurs even after the
re-boot, please contact our technical service dept. for information.
E651003 “There is no need to move”
“没有必要移动。”
[Cause]
There is no need to adjust the Auto. PWB Width Alignment control since the board width got to the
required width already.
[Treatment]
E651004 “The traveling movement has discontinued due to Backup pin detection”
“被支撑台针检查而停止。”
[Cause]
The traveling movement got discontinued since the backup pin detecting sensor detected something
while the movement.
‧A backup pin was detected.
‧A conveying unit (Stopper pin unit, STOP C-OUT sensor unit, Outer shape X pusher unit)
interferes.
‧The installation position of the Backup pin detecting sensor is wrong.
‧The Backup pin detecting sensor is broken.
[Treatment]
‧If a cause of the abortion is a detected backup pin, please adjust a position of the backup pin.
‧If a cause of the abortion is an interference with a conveying unit, please adjust a position of the