JUKI贴片机错误代码集合.pdf - 第381页

Please contact our technical serv ice dept. for information. E691010 “ Lock Bit Clear error occurre d in flush memory cont rol ” “ 闪存卡控制中发生 Lock Bit Cl ear 错误。 ” [Cause] An error occurred while checking the 'lock bi…

100%1 / 464
issued.
The process was aborted since the master lock bit, block lock bit, and RP# lock were detected.
‧Flush memory is broken.
[Treatment]
‧Please turn off the power supply and re-boot your machine.
‧If the error occurs even after the re-boot, there is a possibility that the Safety board is broken.
Please contact our technical service dept. for information.
E691007 Write-in error occurred in flush memory control
闪存卡控制中发生写入错误。
[Cause]
An error occurred while checking the 'Write-in' status after a command to flush memory was issued.
An error occurred while writing data in.
‧Flush memory is broken.
[Treatment]
‧Please turn off the power supply and re-boot your machine.
‧If the error occurs even after the re-boot, there is a possibility that the Safety board is broken.
Please contact our technical service dept. for information.
E691008 Command sequence error occurred in flush memory control
闪存卡控制中发生指令次序错误。
[Cause]
An error occurred while checking the status after a command to flush memory was issued.
A command sequence error occurred.
‧Flush memory is broken.
[Treatment]
‧Please turn off the power supply and re-boot your machine.
‧If the error occurs even after the re-boot, there is a possibility that the Safety board is broken.
Please contact our technical service dept. for information.
E691009 Lock Bit Set error occurred n flush memory control
闪存卡控制中发生Lock Bit Set错误。
[Cause]
An error occurred while checking the 'lock bit set' status after a command to flush memory was
issued.
An error occurred while setting the master/block lock bit.
‧Flush memory is broken.
[Treatment]
‧Please turn off the power supply and re-boot your machine.
‧If the error occurs even after the re-boot, there is a possibility that the Safety board is broken.
Please contact our technical service dept. for information.
E691010 Lock Bit Clear error occurred in flush memory control
闪存卡控制中发生Lock Bit Clear错误。
[Cause]
An error occurred while checking the 'lock bit clear' status after a command to flush memory was
issued.
An error occurred while clearing the lock bit.
‧Flush memory is broken.
[Treatment]
‧Please turn off the power supply and re-boot your machine.
‧If the error occurs even after the re-boot, there is a possibility that the Safety board is broken.
Please contact our technical service dept. for information.
E691011 The check word for the common data of flush memory is abnormal
闪存卡的共通数据的字节校验法(Check Word)错误。
[Cause]
The type of the common data that is saved in the flush memory is irregular.
‧The common data is not saved in the flush memory.
‧Flush memory is broken.
[Treatment]
‧Please re-start the application.
‧Please re-install or version up the application.
‧If the error occurs even after the treatments above were performed, please contact our technical
service dept. for information.
E691012 The checksum for the common data of flush memory is abnormal
闪存卡的共通数据的和数校验法(Check sum)错误。
[Cause]
The common data that is saved in the flush memory is irregular.
‧The common data of flush memory is broken.
‧Flush memory is broken.
[Treatment]
‧Please re-start the application.
‧Please re-install or version up the application.
‧If the error occurs even after the treatments above were performed, please contact our technical
service dept. for information.
E691013 The data version for the common data of flush memory is abnormal
闪存卡的共通数据的数据版本错误
[Cause]
The version of the common data that is saved in the flush memory and the version of the application
are clashing with each other.
‧The application was versioned up.
[Treat]
E691014 The data length for the common data of flush memory is abnormal
闪存卡的共通数据的数据长度错误
[Cause]
The data length of the common data that is saved in the flush memory is irregular.
‧The common data of flush memory is broken.
‧Flush memory is broken.
[Treatment]
‧Please re-start the application.
‧Please re-install or version up the application.
‧If the error occurs even after the treatments above were performed, please contact our technical
service dept. for information.
E691015 The data kind for the common data is abnormal
共通数据的数据种类错误。
[Cause]
Data type parameter is invalid.
[Treatment]
‧Please re-start the application.
‧Please re-install or version up the application.
‧If the error occurs even after the treatments above were performed, please contact our technical
service dept. for information.
E691016 A system error occurred.|The machine type is illegal.”
发生系统错误。|机器类型错误。
E692001 A system error occurred.|The command cannot be executed.”
发生系统错误。|不能执行命令。
E692002 A system error occurred.|There is no response.”
发生系统错误。|没有响应。
E692003 A system error occurred.|The command flag is illegal.”
发生系统错误。|非法命令标记。
E692004 A system error occurred.|The command is illegal.”
发生系统错误。|非法命令。