Please re-teach the ma rks to the machine. Please re-load the production program. Please re-start the applic ation. Please re-boot your machine. E630121 “ Vision System: The cabin et file already exists ” [Cause] There i…

100%1 / 464
Some program versions are clashing with each other.
[Treatment]
Please re-install or version up the application.
Please re-boot your machine.
Please contact our technical service dept. for information.
E630117 Vision System: It is unprescribed NAK code. NAK17 code
图像处理装置错误:|不标准的 NAK 代码。 NAK 的代码是 17
[Cause]
Unprescribed response was sent back from VCS.
Some program versions are clashing with each other.
[Treatment]
Please re-install or version up the application.
Please re-boot your machine.
Please contact our technical service dept. for information.
E630118 Vision System: It is unprescribed NAK code. NAK18 code
图像处理装置错误:|不标准的 NAK 代码。 NAK 的代码是 18
[Cause]
Unprescribed response was sent back from VCS.
Some program versions are clashing with each other.
[Treatment]
Please re-install or version up the application.
Please re-boot your machine.
Please contact our technical service dept. for information.
E630119 Vision System: It is unprescribed NAK code. NAK19 code
图像处理装置错误:|不标准的 NAK 代码。 NAK 的代码是 19
[Cause]
Unprescribed response was sent back from VCS.
Some program versions are clashing with each other.
[Treatment]
Please re-install or version up the application.
Please re-boot your machine.
Please contact our technical service dept. for information.
E630120 Vision System: There is no cabinet file
[Cause]
There is a mistake in the Sequence control in the User defined template.
[Treatment]
Please re-teach the marks to the machine.
Please re-load the production program.
Please re-start the application.
Please re-boot your machine.
E630121 Vision System: The cabinet file already exists
[Cause]
There is a mistake in the Sequence control in the User defined template.
[Treatment]
Please re-teach the marks to the machine.
Please re-load the production program.
Please re-start the application.
Please re-boot your machine.
E630122 Vision System: Failed to open the cabinet file
[Cause]
There is a mistake in the Sequence control in the User defined template.
[Treatment]
Please re-teach the marks to the machine.
Please re-load the production program.
Please re-start the application.
Please re-boot your machine.
E630123 Vision System: An error of reading the cabinet file
[Cause]
There is a mistake in the Sequence control in the User defined template.
[Treatment]
Please re-teach the marks to the machine.
Please re-load the production program.
Please re-start the application.
Please re-boot your machine.
E630124 Vision System: An error of writing the cabinet file
[Cause]
There is a mistake in the Sequence control in the User defined template.
[Treatment]
Please re-teach the marks to the machine.
Please re-load the production program.
Please re-start the application.
Please re-boot your machine.
E630125 Vision System: A data error of the cabinet file
[Cause]
There is a mistake in the Sequence control in the User defined template.
[Treatment]
Please re-teach the marks to the machine.
Please re-load the production program.
Please re-start the application.
Please re-boot your machine.
E630200 Vision System: A bass error occurred. Hardware abnormality
图像处理 CPU 错误:|总线错误
[Cause]
IMGCPU is broken.
The program could not be written in the IMGCPU properly.
[Treatment]
Please change IMGCPUs.
Please re-write the program in the IMGCPU.
Please re-boot your machine.
E630201 Vision System: An address error occurred. Hardware abnormality
图像处理 CPU 错误:|地址错误
[Cause]
IMGCPU is broken.
The program could not be written in the IMGCPU properly.
[Treatment]
Please change IMGCPUs.
Please re-write the program in the IMGCPU.
Please re-boot your machine.
E630202 Vision System: A spurious interruption error occurred. Hardware abnormality
图像处理 CPU 错误:|逻辑错误(Spurious)
[Cause]
IMGCPU is broken.
The program could not be written in the IMGCPU properly.
[Treatment]
Please change IMGCPUs.
Please re-write the program in the IMGCPU.
Please re-boot your machine.
E630203 Vision System: It is unprescribed ERR code. ERR3 code