JUKI贴片机错误代码集合.pdf - 第130页
“ 轴发生错误。 ” [Cause] Something was wrong with axis movement. [Treatment] Please perform the Home returning. E510005 “ The command error occurred ” “ 发生命令错误。 ” [Cause] An UN-recognizable command was issued. [Treatment] A wr…
“错误级别低于警告级别。|ATC : 不能设置%s 的错误级别。”
I509210 “error level is over the Warning level.|The warning level of %s can not be set.”
“警告级别高于错误级别。|不能设置%s 的警告级别。”
I509211 “The warning level is less than the error level.|The error level of %s can not be set.”
“错误级别低于警告级别。|不能设置%s 的错误级别。”
Q509300 “Number of picked components is over the error level.|Number of picked components %d error
level %d|Would you like to set the data?”
“ATC 交换次数超过错误级别。|ATC 交换次数:%d 错误级别:%d|是否设置资料?”
Q509301 “Number of placed components is over the Number of picked components.|Number of placed
components %d Number of picked components %d|Would you like to set the data?”
“总贴片数超过总吸取数。|总贴片数:%d 总吸取数:%d|是否设置资料?”
Q509302 “Number of placed components is over the Number of picked components.|Number of placed
components %d Number of picked components %d|Would you like to set the data?”
“ 交换吸嘴次数超过总吸取数。|交换吸嘴次数:%d 总吸取数:%d|是否设置资料?”
E510001 “The error occurred by the XY axis”
“XY 轴发生错误。”
[Cause]
Something was wrong with XY axes movement.
[Treatment]
Please perform the Home returning.
E510002 “The error occurred by the Z axis”
“Z 轴发生错误。”
[Cause]
Something was wrong with XY axes movement.
[Treatment]
Please perform the Home returning.
E510003 “The error occurred by the Theta axis”
“θ轴发生错误。”
[Cause]
Something was wrong with the Theta axis movement.
[Treatment]
Please perform the Home returning.
E510004 “The error occurred by the axis”
“轴发生错误。”
[Cause]
Something was wrong with axis movement.
[Treatment]
Please perform the Home returning.
E510005 “The command error occurred”
“发生命令错误。”
[Cause]
An UN-recognizable command was issued.
[Treatment]
A wrong version has been installed.
Please install the latest software.
E510006 “Failed in the opening of the master schedule”
“打开主调度程序失败。”
[Cause]
The software did not get started properly.
[Treatment]
Please turn off the power supply of the machine and reboot it.
E510007 “Failed in create of the mail of the scheduler”
“创建调度程序邮件失败。”
[Cause]
The software did not get started properly.
[Treatment]
Please turn off the power supply of the machine and reboot it.
E510008 “Failed in the opening of the mail of the application-manager”
“打开程序管理邮件失败。”
[Cause]
The software did not get started properly.
[Treatment]
Please turn off the power supply of the machine and reboot it.
E510009 “Failed in the mail transmission to the application-manager”
“往程序管理发送邮件失败。”
[Cause]
The software did not get started properly.
[Treatment]
Please turn off the power supply of the machine and reboot it.
E510010 “Failed in the mail check”
“检查邮件失败。”
[Cause]
The software did not get started properly.
[Treatment]
Please turn off the power supply of the machine and reboot it.
E510011 “Failed in the mail reception”
“接收邮件失败。”
[Cause]
The software did not get started properly.
[Treatment]
Please turn off the power supply of the machine and reboot it.
E510012 “Failed in the opening of the mail of the production-control”
“打开生产管理邮件失败。”
[Cause]
The software did not get started properly.
[Treatment]
Please turn off the power supply of the machine and reboot it.
E510013 “Failed in the transmission of the mail to the production-control”
“往生产管理发送邮件失败。”
[Cause]
The software did not get started properly.
[Treatment]
Please turn off the power supply of the machine and reboot it.
E510014 “Failed in the opening of the command of the Trans-driver”
“打开传送驱动命令失败。”
[Cause]
The software did not get started properly.
[Treatment]
Please turn off the power supply of the machine and reboot it.
E510015 “Failed in the transmission of the command to the Trans-driver”
“往传送驱动器发送命令失败。”
[Cause]
The software did not get started properly.
[Treatment]
Please turn off the power supply of the machine and reboot it.