E241034 “ The area sensor was detected.| P lease remove the sensor reactio n factor .” “ 因范围 不正常实施暂停。 | 请查出原因并纠正。 ” E241035 “ The feeder float sensor was detected.| Please remove the sensor reaction factor .” “ 查出传 送带浮动。…
number is always larger than the starting component number.
W241025 “Measurement item is not selected”
“没有选择测定项目。”
[Cause]
Measurement cannot be performed since no measurement items are selected.
[Treatment]
Please select necessary measurement items.
E241026 “There is not a measurement possible component”
“要测定的组件不存在。”
[Cause]
As a result of a search by measurement conditions, there is no component that can be measured.
[Treatment]
Please check the measurement(inspection) conditions.
W241027 “The size relation of length and width does not agree with data.|width: %s ( %s ) length: %s ( %s )
|There is possibility that the setting of outline or direction are not fitting.”
“测量组件大小的结果,组件的长宽被颠倒。|宽度: %s ( %s ) 长度: %s ( %s ) |组件供给角
度设置可能有错。
E241028 “There is not a inspection possible component”
“要检查的组件不存在。”
[Cause]
A result of a search by inspection conditions, there is no component that can be inspected.
[Treatment]
Please check the inspection conditions.
E241029 “MTC is disable.”
“不能使用 MTC。”
E241030 “MTS is disable.”
“不能使用 MTS。”
E241031 “The origin point return does not end.|Please retry after completing the origin point return.”
“未结束返回原点。|返回原点结束后,请再次运行。”
E241032 “The servo motor is free.|Please retry after releasing the servo free state.”
“伺服马达处于未起动状态。|请起动伺服马达后,再次运行。”
E241033 “The interrupt which was not able to operate was detected. | The processing is interrupted.”
“查出不能运行的操作。|停止处理。”
E241034 “The area sensor was detected.| Please remove the sensor reaction factor.”
“因范围不正常实施暂停。| 请查出原因并纠正。”
E241035 “The feeder float sensor was detected.| Please remove the sensor reaction factor.”
“查出传送带浮动。|请纠正传送带浮动。”
I241200 “A continuous measurement ended”
“结束连续测量。”
[Cause]
This message appears to inform you the end(interruption) of the continuous measurement.
[Treatment]
Please press the 'OK' button.
I241201 “A continuous inspection ended”
“结束连续检查。”
[Cause]
This message appears to inform you the end(interruption) of the continuous inspection.
[Treatment]
Please press the 'OK' button.
Q241300 “Do you interrupt process?”
“是否中断处理?”
[Cause]
You are asked if to abort the process when the STOP switch is pressed during the execution of the
process.
[Treatment]
'YES' button will abort the process.
'NO' button will continue the process.
Q241301 “A noz. When calculated from the outline that measured and a noz. When at present is set up
differes. | A calculation noz. No. : %3d | A setting noz. No. : %3d | Does it renew a noz.? | When a
noz. Is renewed vacuum level is initialized”
“根据测量组件大小结果,算出的吸嘴号和当前使用的吸嘴号不相同。|算出吸嘴号:%d|设
置吸嘴号:%d|是否更新吸嘴号?(将初始化真空压)”
[Cause]
A nozzle number calculated from the measured component outline and a nozzle number that is
specified in the Component data differs from each other. You are asked if to perform a nozzle change.
1): A nozzle number calculated from the measured component outline.
2): A nozzle number that is specified in the Component data
[Treatment]
'YES' button will change the nozzle number to a calculated nozzle number. At this point, [Vacuum
pressure of component picking] in the Component data is initialized.
'NO' button will not change the nozzle number. Other measured data will be valid.
Q241302 “A nozzle number when calculated from the measurement result and a nozzle number when at
present is set up differes. | Is the nozzle exchanged?”
“ 根据测量组件大小结果,算出的吸嘴号和当前使用的吸嘴号不相同。|是否更换吸嘴?”
[Cause]
A nozzle number calculated from the measured component outline and a nozzle number that is
specified in the Component data differs from each other. You are asked if to perform a nozzle change.
[Treatment]
'YES' button will perform a nozzle change, and continue to measure vacuum pressure and the lead
information. 'NO' button will not perform a nozzle change, but continue to measure vacuum pressure
and the lead information.
Q241303 “A pick position is changed. | Does it renew a pick data?”
“吸取位置已变更。|是否更新吸取数据?”
[Cause]
You are asked if to take the pick position currently displayed into the Pick data when 'Update pick
data with new coordinates' on the Measurement screen is enabled and the pick position was updated
by manual input or teaching.
[Treatment]
'YES' button will update the Pick data. 'NO' button will not update the Pick data.
Q241304 “A pick position is changed.|Does it renew a pick data ?|When it renews it optimization data
becomes ineffective.”
“ 吸取位置已变更。|是否更新吸取数据?|如果更新,最优化数据就变成无效。”
E241305 “The measurement error occurred. Do you start single measurement?”
“测量发生错误,是否进行单独测量?”
[Cause]
When a measurement error occurred during the continuous measurement, you are asked if to perform
a single measurement for a component that is a cause of the error.
[Treatment]
'YES' button will take you to the screen where you can perform the a single measurement for the
component. 'NO' button will take you back to the screen where you can resume the continuous
measurement. You can perform a single measurement from the continuous measurement result screen.
W241306 “The size relation of length and width does not agree with data. | Width : %s(%s) length : %s(%s) |
There is possibility that the setting of outline or direction are not fitting. Do you reflect the
measurement result in the component data?”
“测量组件大小的结果,组件的长宽被颠倒。宽度: %s ( %s ) 长度: %s ( %s ) |有可能组件供