be performed by selecting [Machin e Setup] from the menu bar, an d then [Sett ing Group(G)] [ATC Nozzle Allocation(A)]. E610031 “ Parameter for the cy li nder is not correct ” “ 圆筒的参数不正确。 ” [Cause] The specifying of ATC …
this point, if the image data does not get shown, please turn off the power supply and try again. If the
image data does not get shown even after the retry, MCM board in the laser sensor is not installed
properly or the sensor itself is broken. Please turn off the power supply and see if the MCM board is
installed in the sensor correctly.
E610028 “An error occurred when detecting the presence of Laser nozzle”
“检查吸嘴是否存在时发生错误。”
[Cause]
An error occurred when setting a window size to check a nozzle presence by the laser recognition
unit.
[Treatment]
There is a possibility that the laser recognition unit has a problem. You can check if it is fine or now
with the following procedures. Please select [Manual Control] from the menu bar, and then select
[Control(C)] [Head(H)] [Laser Control(L)].Select a concerned laser sensor in 'Control' unit, and then
select 'Image displaying' from 'Control Item' frame. By enabling ON, an image data will be shown. At
this point, if the image data does not get shown, please turn off the power supply and try again. If the
image data does not get shown even after the retry, MCM board in the laser sensor is not installed
properly or the sensor itself is broken. Please turn off the power supply and see if the MCM board is
installed in the sensor correctly.
E610029 “An error occurred when learning laser height of Laser nozzle”
“激光识别器测量激光高度发生错误。”
[Cause]
An error occurred when measuring a nozzle length by the laser recognition unit.
[Treatment]
There is a possibility that the laser recognition unit has a problem. You can check if it is fine or now
with the following procedures. Please select [Manual Control] from the menu bar, and then select
[Control(C)] [Head(H)] [Laser Control(L)].Select a concerned laser sensor in 'Control' unit, and then
select 'Image displaying' from 'Control Item' frame. By enabling ON, an image data will be shown. At
this point, if the image data does not get shown, please turn off the power supply and try again. If the
image data does not get shown even after the retry, MCM board in the laser sensor is not installed
properly or the sensor itself is broken. Please turn off the power supply and see if the MCM board is
installed in the sensor correctly.
E610030 “Nozzles can not be detected”
“没有发现吸嘴。”
[Cause]
No nozzle could not be found in the Nozzle presence check by laser. Nozzles are not set in the ATC.
[Treatment]
Please set nozzle(s) on ATC and perform the ATC nozzle allocation. The ATC Nozzle allocation can
be performed by selecting [Machine Setup] from the menu bar, and then [Setting Group(G)] [ATC
Nozzle Allocation(A)].
E610031 “Parameter for the cylinder is not correct”
“圆筒的参数不正确。”
[Cause]
The specifying of ATC position is abnormal. The data in the machine is broken or the version of the
software that is installed on the machine is not correct.
[Treatment]
‧Please turn off the power supply of your machine and reboot it.
‧If the error occurred after the installation or the version up of the software, you need to re-install
the software.
‧If the treatments above do not work, there is a possibility that board(s) in the machine is broken.
You need to replace it(them) with new ones.
E610032 “The head is not set to use”
“Head 处于不使用状态。”
[Cause]
The specified head is not enabled to use. The head is set to “not use” in the Machine Setup.
[Treatment]
Please set the concerned head to “use” in the Machine Setup or try another head. You can set the head
to “use” in the Machine Setup with the following procedures. Select [Machine Setup] from the menu
bar, and then select [Setting Group(G)][Use Unit(D)]. Open a dialog with a tub 'Use Unit1', and check
in the checkbox of a concerned head.
E610033 “ATC X coordinate is abnormal”
“X 坐标参数不正确。”
[Cause]
The specified ATC X coordinate is abnormal. Or the specified coordinate exceeds the permissive
range of the nozzle exchange. The data in the machine is broken or the version of the software that is
installed on the machine is not correct.
[Treatment]
‧Please turn off the power supply of your machine and reboot it.
‧If the error occurred after the installation or the version up of the software, you need to re-install
the software.
‧If the treatments above do not work, there is a possibility that board(s) in the machine is broken.
You need to replace it(them) with new ones.
E610034 “ATC Y coordinate is abnormal”
“Y 坐标参数不正确。”
[Cause]
The specified ATC Y coordinate is abnormal. Or the specified coordinate exceeds the permissive
range of the nozzle exchange. The data in the machine is broken or the version of the software that is
installed on the machine is not correct.
[Treatment]
‧Please turn off the power supply of your machine and reboot it.
‧If the error occurred after the installation or the version up of the software, you need to re-install
the software.
‧If the treatments above do not work, there is a possibility that board(s) in the machine is broken.
You need to replace it(them) with new ones.
E610035 “ATC Y coordinate range error occurred”
“Y 坐标的误差超过允许范围。”
[Cause]
The specified ATC Y coordinate is abnormal. Or the specified coordinate exceeds the permissive
range of the nozzle exchange. The data in the machine is broken or the version of the software that is
installed on the machine is not correct.
[Treatment]
‧Please turn off the power supply of your machine and reboot it.
‧If the error occurred after the installation or the version up of the software, you need to re-install
the software.
If the treatments above do not work, there is a possibility that board(s) in the machine is broken. You
need to replace it(them) with new ones.
E610036 “There is no nozzle in the cylinder”
“圆筒上没有吸嘴。”
[Cause]
No nozzle could not be found in the Nozzle presence check by laser. There is a possibility that a
nozzle was taken away from ATC manually or a nozzle installation failed.
[Treatment]
1. If the nozzle was taken away from ATC manually.
Set the nozzle on ATC. If you are not sure which nozzle to set back on ATC, please set a nozzle on
ATC for a time being and perform ATC nozzle allocation. The ATC nozzle allocation can be
performed by selecting [Machine Setup] from the menu bar and then [Setting Group(G)] [ATC
Nozzle Allocation(A)].
2. There was a nozzle on ATC but its installation was not correct.
The following causes are possibly. Please find a cause.
‧There is oily stuff such as grease between the brim of the nozzle that touches ATC and the
installation side of ATC. If there is any oily stuff, please remove it.