JUKI贴片机错误代码集合.pdf - 第450页

E6105 Pl ease select component. " 请选择组件。 " [Cause] Appears if the number of supplie s change butt on is pressed with out a list selected. [Deal] Click the part name to highlight it and press the change butto n …

100%1 / 464
"显示对话框失败。"
E6007 System error has occurred.
"出现系统错误。"
[Cause]
After creating a table for mounting, creating a feeder layout window with no mounting data was
failed.
[Deal]
Consult the manufacturer.
E6008 Failed to combine the program.
[Cause]
Merging the divided programs was failed.
[Deal]
Retry the process.
E6009 Tact simulation failed.
[Cause]
An error was detected at the line entry. Insufficient free space in the memory or a failure on the disk
is suspected.
[Deal]
Run the "Scan-disk" to check the disk. Exit from other applications, and retry the process.
E6100 Number supplied is out of range.
"供给的数量超出范围。"
[Cause]
An excessive value was specified for the number of supplies.
[Deal]
Enter a value within the range.
E6101 Error occurred in finding number supplied, upper limit of number supplied or lower limit of
number supplied.
"在查找提供数量时出现错误,增加提供的数量限制或降低提供的数量限制。"
E6102 HLC.INI file read-in failed.
"读入 HLC.INI 文件失败。"
E6103 Data is input so as to eliminate all machine stations from partition destinations.
" 数据被输入为了从注定分开区域终止所有机器位置。"
E6104 Number of distributed stations is outside limits.
"分配位置数量超过外部限制。"
E6105 Please select component.
"请选择组件。"
[Cause]
Appears if the number of supplies change button is pressed without a list selected.
[Deal]
Click the part name to highlight it and press the change button or double-click the part name.
E6106 HLCSETUP.INI file read-in failed.
"读入 HLCSETUP.INI 文件失败。"
E6109 Enter numeric value.
[Cause]
Appears if no numeric value or any value other than numeric is specified for the feedback option and
the number of redundant factors.
[Deal]
Specify valid values for the feedback option or the number of redundant factors.
E6110 Setting of the number of max loop count is out of range.
[Cause]
An excessive number of the maximum loops was specified for the feedback option.
[Deal]
Enter a value within the range, 1 to 9.
E6111 Setting of target difference time is out of range.
[Cause]
Excessive value was specified for the allowable interval of the feedback option.
[Deal]
Enter a value within the range, 0 to 60 seconds.
E6112 Cannot distribute data with this setting.
[Cause]
For every station, 0 is specified in the balance option.
[Deal]
Check the station to allocate mounting points or application points, and specify the distribution.
E6113 Setting of balance is out of range.
[Cause]
An excessive value was specified for the balance option.
[Deal]
Enter a vale within the range, 0 to 100.
E6114 Setting of room coefficient is out of range.
[Cause]
An excessive value was specified for the redundant factor.
[Deal]
Enter a value within the range, 0 to 100.
E6250 Area cannot be secured.
"区域不能被保护。"
E6251 INI file cannot be read.
"不能读 INI 文件。"
E6252 Distributed data cannot be read.
"不能读分配数据。"
E6253 Data combining failed.
"数据结合失败。"
E6254 Combining of data failed because data are mutually exclusive.
"由于数据相互排斥数据结合失败。"
E6255 Combined data cannot be output.
"不能输出组合数据。"
E6300 Setting of number of programs etc. failed.
"设置程序数量等失败。"
E6350 Area cannot be secured.
"区域不能被保护。"
[Cause]
Allocating the memory for EPU was failed. Allocating the memory for G3h and G3N was failed.
[Deal]
Exit from other applications and retry the process.
E6351 File read failed.
"不能读预定程序目录。"
[Cause]
Loading files, G3H and GXL, was failed. Insufficient free space on the memory or any failure on the
disk is suspected.
[Deal]
Run the "Scan-disk" to check the disk. Exit from other applica
tions and retry installation.