‧Component Verification is broken. [Treatment] ‧Please ch eck and see if the object is contacting t he probe we ll. If not, please adjust the positi on of the object to contact the probe properl y. ‧If the error occurs w…

100%1 / 464
‧If the error occurs even after the re-boot, there is a possibility that the Component Verification
unit is broken. Please contact our technical service dept. for information.
E690017 A time-out occurred while reading volume in
读取电容超时。
[Cause]
The tester does not start outputting data when starting to measure the condenser capacity.
‧Component Verification is broken.
[Treatment]
‧Please turn off the power supply and re-boot your machine.
‧If the error occurs even after the re-boot, there is a possibility that the Component Verification
unit is broken. Please contact our technical service dept. for information.
E690018 A time-out occurred while reading voltage in
读取电压超时。
[Cause]
The tester does not start outputting data when starting to measure the voltage.
‧Component Verification is broken.
[Treatment]
‧Please turn off the power supply and re-boot your machine.
‧If the error occurs even after the re-boot, there is a possibility that the Component Verification
unit is broken. Please contact our technical service dept. for information.
E690019 The measured resistance does not get stable. | Please check the probe status
读取的电阻不稳定。|请检查探针状态
[Cause]
The resistance gotten from the tester does not get stable.
‧The object(component) of the measurement is not contacting the probe well.
‧Component Verification is broken.
[Treatment]
‧Please check and see if the object is contacting the probe well. If not, please adjust the position of
the object to contact the probe properly.
‧If the error occurs when the contact is good, there is a possibility that the Component Verification
unit is broken. Please contact our technical service dept. for information.
E690020 The measured volume does not get stable. | Please check the probe status
读取的电容不稳定。|请检查探针状态
[Cause]
The condenser capacity gotten from the tester does not get stable.
‧The object(component) of the measurement is not contacting the probe well.
‧Component Verification is broken.
[Treatment]
‧Please check and see if the object is contacting the probe well. If not, please adjust the position of
the object to contact the probe properly.
‧If the error occurs when the contact is good, there is a possibility that the Component Verification
unit is broken. Please contact our technical service dept. for information.
E690021 The measured voltage does not get stable. | Please check the probe status
读取的电压不稳定。|请检查探针状态
[Cause]
The voltage gotten from the tester does not get stable.
‧The object(component) of the measurement is not contacting the probe well.
‧Component Verification is broken.
[Treatment]
‧Please check and see if the object is contacting the probe well. If not, please adjust the position of
the object to contact the probe properly.
‧If the error occurs when the contact is good, there is a possibility that the Component Verification
unit is broken. Please contact our technical service dept. for information.
E690022 Something is wrong with the measured resistance
测定的电阻有些异常。
[Cause]
The resistance gotten from the tester is irregular.
‧The object(component) of the measurement is not contacting the probe well.
‧Component Verification is broken.
[Treatment]
‧Please check and see if the object is contacting the probe well. If not, please adjust the position of
the object to contact the probe properly.
‧If the error occurs when the contact is good, there is a possibility that the Component Verification
unit is broken. Please contact our technical service dept. for information.
E690023 Something is wrong with the measured volume
测定的电容有些异常。
[Cause]
The condenser capacity gotten from the tester is irregular.
‧The object(component) of the measurement is not contacting the probe well.
‧Component Verification is broken.
[Treatment]
‧Please check and see if the object is contacting the probe well. If not, please adjust the position of
the object to contact the probe properly.
‧If the error occurs when the contact is good, there is a possibility that the Component Verification
unit is broken. Please contact our technical service dept. for information.
E690024 Something is wrong with the measured voltage
测定的电压有些异常。
[Cause]
The voltage gotten from the tester is irregular.
‧The object(component) of the measurement is not contacting the probe well.
‧Component Verification is broken.
[Treatment]
‧Please check and see if the object is contacting the probe well. If not, please adjust the position of
the object to contact the probe properly.
‧If the error occurs when the contact is good, there is a possibility that the Component Verification
unit is broken. Please contact our technical service dept. for information.
E690025 Something is wrong with the measured resistance(unit)
测定的电阻(单位)有些异常。
[Cause]
The unit for the resistance gotten from the tester is irregular.
‧The object(component) of the measurement is not contacting the probe well.
‧Component Verification is broken.
[Treatment]
‧Please check and see if the object is contacting the probe well. If not, please adjust the position of
the object to contact the probe properly.
‧If the error occurs when the contact is good, there is a possibility that the Component Verification
unit is broken. Please contact our technical service dept. for information.
E690026 Something is wrong with the measured volume(unit)
测定的电容(单位)有些异常。
[Cause]
The unit for the condenser capacity gotten from the tester is irregular.
‧The object(component) of the measurement is not contacting the probe well.
‧Component Verification is broken.
[Treatment]
‧Please check and see if the object is contacting the probe well. If not, please adjust the position of
the object to contact the probe properly.
‧If the error occurs when the contact is good, there is a possibility that the Component Verification
unit is broken. Please contact our technical service dept. for information.
E690027 Something is wrong with the measured voltage(unit)