JUKI贴片机错误代码集合.pdf - 第428页
[Cause] The maximum number of part data a vailable for one stati on varie s depending on station t ypes: 80 for 710, 81 for 720, 200 for 770, and 120 for 730, 740, 750,7 60,2000 series,240 for 775. [Deal] Decrease the nu…
[Deal]
Set the IC head or LAIC head to "Used" in the "Unit conditions" field of the "Station profile"
window invoked from the MSL Setup program.
E3809 No station VCS or option VCS useful exists.
"在线上没有位置能使用随意的 VCS."
[Cause]
Appears if the item, standard VCS or option VCS, is disabled in the unit status of the station profile
during the MSL setup.
[Deal]
Enable the item, standard VCS or option VCS, in the unit status of the station profile during the
MSL setup.
E3810 option VCS cannot be used on selected station.
"指定的位置没有设置成使用可选择的 VCS."
[Cause]
Appears if the item option VCS is disabled in the unit status for the station profile during the MSL
setup, with 720, 740,760,2020,2040 specified for the station.
[Deal]
Enable the item option VCS in the unit status of the station profile for the specified station.
E3811 No station optioned with chip stand detect is in the line.
"在线上没有位置能有芯片站立探测."
[Cause]
Appears if 710 or 720 is set for the line but the item, chip-standup detector, is disabled in the unit
status of the station profile during the MSL setup.
[Deal]
Enable the item, chip-standup detector, in the unit status of the station profile during the MSL setup.
E3812 Chip stand detect option cannot be used on selected station.
"芯片站立探测项不能在选择位置使用."
[Cause]
Although a 710 or 720 is specified for the line, "Not used" is specified for the chip stand detect option
unit in the "Unit conditions" field of the "Station profile" window which is invoked from the MSL
Setup program.
[Deal]
Set the chip stand detect option to "Used" in the "Unit conditions" field of the "Station profile"
window which is invoked from the MSL Setup program.
E3813 Component data per a station exceeds maximum.
"每个位置的组件数据超出最大值."
[Cause]
The maximum number of part data available for one station varies depending on station types: 80 for
710, 81 for 720,200 for 770, and 120 for 730, 740, 750,760,2000 series,240 for 775.
[Deal]
Decrease the number of part data to the acceptable level.
E3814 An unusable head is assigned in selected station.
"在选择位置分配不可使用头."
[Cause]
The necessary head is not set for the specified station in the "Unit conditions" field of the "Station
profile" window which is invoked from the MSL Setup program.
[Deal]
Set the necessary head in the "Unit conditions" field of the "Station profile" window which is
invoked from the MSL Setup program.
E3815 A necessary needle is not in selected station.
"必须的针没有在选择位置."
[Cause]
Appears if the needle required for the specified station is not set in the unit status of the station profile
during the MSL setup.
[Deal]
Specify the necessary needle in the unit status of the specified station for the specified station.
E3816 Adhesive data per a station exceeds maximum.
"每个位置的贴装数据超过最大值."
[Cause]
Indicates that more than 200 adhesion data were set but there is only one 770 on the line or, 240 or
more adhesive data pieces were set although there is only one 775 installed on the line.
[Deal]
Decrease the number of the adhesion data to the limit or less.
E3817 “No vision centering station is in the line. “
"在线上没有图像中心位置."
E3818 Station which can handle tray package is not in the line.
"能处理盘包装的位置不在线上."
[Cause]
Appears if no station capable of using trays is set for the line but trays are used.
[Deal]
E3819 Station which can handle No.5 nozzle is not in the line.
"能处理 5 号吸嘴的位置不在线上."
[Cause]
Indicates that there is no 720 station on the preset line during the MSL setup.
[Deal]
Add a 720 station or do not use nozzle 5.
Set a station capable of using trays on the line.
E3820 The number of selected nozzle is set as 0 in resource table.
"选择吸嘴的数量在资源表中设置为 0."
[Cause]
Indicates that the number of nozzles is set to 0 on the resource table during the MSL setup.
[Deal]
Specify an appropriate value for the resource table of the specified nozzle during the MSL setup.
E3821 Station which can handle component more than 6mm is not in the line.
"能处理 6mm 以上组件的位置不在线上."
[Cause]
Indicates that there is none of 720, 730, 740,750,760,2010,2020 or 2040.
[Deal]
Add any of a 720, 730, 740,750, 760,2010,2020 or 2040 station during the MSL setup.
E3822 The number of selected tape feeder is set as 0 in resource table.
"选择带状送料器的数量在资源表中设置为 0."
[Cause]
Indicates that the number of the tape feeders of the specified tape width is set to 0 on the resource
table during the MSL setup.
[Deal]
Specify an appropriate value for the number of the tape feeders of the specified tape width on the
resource table during the MSL setup.
E3823 The number of selected stick feeder is set as 0 in resource table.
"选择管状供料器的数量在资源表中设置为 0."
[Cause]
Indicates that the number of the specified stick feeder types is set to 0 in the resource table during the
MSL setup.
[Deal]
Specify an appropriate value for the number of the specified stick feeder types in the resource table
during the MSL setup.